Yishan Qian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yishan Qian has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Xingtao Zhou
Eye Institute and Department of Ophthalmology Eye & ENT Hospital, Fudan University Shanghai China
11 shared publications Xingtao Zhou
Department of Ophthalmology, Eye and ENT Hospital, NHC Key Laboratory of Myopia (Fudan University), Fudan University, Shanghai, People’s Republic of China
7 shared publicationsFeng Xue
Department of Ophthalmology, Eye and ENT Hospital, Fudan University; Key Laboratory of Myopia of The State Health Ministry, 200031, 83 Fenyang Road, Shanghai, People’s Republic of China
5 shared publicationsJiaqi Zhou
Department of Ophthalmology, Eye and ENT Hospital, Fudan University; Key Laboratory of Myopia of The State Health Ministry, 200031, 83 Fenyang Road, Shanghai, People’s Republic of China
5 shared publicationsLan Ding
Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, People’s Republic of China
5 shared publicationsRajeev Krishnan Naidu
Sydney Eye Hospital, Sydney, NSW, 2000, Australia
5 shared publications
Latest Publications
- 22 July 2026
- Published by Springer Nature in Eye
- Vol. 40 (15) , 2410-2416
A novel method for evaluating the thickness and keratometry profiles of toric lenticules created by a new-generation keratorefractive lenticule extraction platform
Purpose To investigate the thickness and keratometry profiles of toric lenticules created by keratorefractive lenticule extraction (KLEx) using the VISUMAX 800 femtosecond laser platform. Methods This prospective study included the right eyes of 42 patients who underwent KLEx with VISUMAX 800 for correction of myopia and myopic astigmatism. Custom software generated spatial profiles of lenticule thickness (LT) and surgically-induced change in keratometry (SIK) based on raw pre- and postoperative tomographic data. The following indices were calculated: lenticule thickness per unit dioptre (LT/D), LT at the steep and flat meridians and their difference (LTF-S), percentage of lenticule thickness decrease (PLTD) and SIK at the steep and flat meridians. Results A significant difference in average LT/D was observed across optical zones (OZ), with LT/D with OZ increasing non-linearly with OZs. The lenticule exhibited a convex shape, thinning more rapidly towards the periphery. Flat LT/D exceeded steep LT/D and the difference (LTF-S) correlated positively with cylindrical error. Flat PLTD was lower than steep PLTD, indicating a slower rate of thickness decrease along the flat axis. Steep SIK exceeded flat SIK within the central 1–2 mm but was lower than flat SIK from 4 to 7 mm. Conclusions The spatial profiles of LT and SIK reflect the toric treatment module for astigmatic correction. This study introduces a method for in vivo measurement of lenticular spatial profiles, enabling quantitative assessment of lenticule geometry.
- 22 July 2026
- Published by Springer Nature in Eye
- Vol. 40 (15) , 2410-2416
A novel method for evaluating the thickness and keratometry profiles of toric lenticules created by a new-generation keratorefractive lenticule extraction platform
Purpose To investigate the thickness and keratometry profiles of toric lenticules created by keratorefractive lenticule extraction (KLEx) using the VISUMAX 800 femtosecond laser platform. Methods This prospective study included the right eyes of 42 patients who underwent KLEx with VISUMAX 800 for correction of myopia and myopic astigmatism. Custom software generated spatial profiles of lenticule thickness (LT) and surgically-induced change in keratometry (SIK) based on raw pre- and postoperative tomographic data. The following indices were calculated: lenticule thickness per unit dioptre (LT/D), LT at the steep and flat meridians and their difference (LTF-S), percentage of lenticule thickness decrease (PLTD) and SIK at the steep and flat meridians. Results A significant difference in average LT/D was observed across optical zones (OZ), with LT/D with OZ increasing non-linearly with OZs. The lenticule exhibited a convex shape, thinning more rapidly towards the periphery. Flat LT/D exceeded steep LT/D and the difference (LTF-S) correlated positively with cylindrical error. Flat PLTD was lower than steep PLTD, indicating a slower rate of thickness decrease along the flat axis. Steep SIK exceeded flat SIK within the central 1–2 mm but was lower than flat SIK from 4 to 7 mm. Conclusions The spatial profiles of LT and SIK reflect the toric treatment module for astigmatic correction. This study introduces a method for in vivo measurement of lenticular spatial profiles, enabling quantitative assessment of lenticule geometry.
- 17 June 2026
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 49 (4) , 102688
Comparison of corneoscleral topographic consistency in eyes with low-to-moderate and high astigmatism
- 17 June 2026
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 49 (4) , 102688
Comparison of corneoscleral topographic consistency in eyes with low-to-moderate and high astigmatism
- 5 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (10) , 903-908
Short-term Change in Haptic position of Implantable Collamer Lenses and its correlation with the variation of vault
Purpose: To examine changes in the haptic position of the implantable collamer lens (ICL) within the postoperative3 months and its correlation with vault variation. Setting: Eye and ENT Hospital, Fudan University, Shanghai, China. Design: Prospective non-randomized study. Methods: This study included 58 right eyes of 58 patients who underwent ICL implantation for the correction of myopia or myopic astigmatism. The position of the ICL haptic was measured using ultrasound biomicroscopy (UBM) at postoperative 1 month (P1M) and 3 months (P3M) and was classified into three types: haptic in the ciliary sulcus (ICS), haptic in the ciliary body (ICB), and haptic under the ciliary body (UCB). Results: Among haptics classified as ICS at P1M (n=131), 120 remained ICS (91.60%), 9 became ICB (6.87%), and 2 became UCB (1.53%) at P3M. Among haptics classified as ICB at P1M (n=66), 44 remained ICB (66.67%), 17 became ICS (25.76%), and 5 became UCB (7.58%). Among haptics classified as UCB at P1M (n=35), 26 remained UCB (74.29%) and 9 became ICB (25.71%). The maximum ciliary body thickness (CBTmax, P=0.010), iris thickness at 500 μm (IT500, P=0.029), and trabecular-ciliary angle (TCA, P=0.045) were associated with ΔIRHP3M-P1M (distance between the iris root and the tip of haptic, P3M-P1M). Anterior chamber depth (ACD, P=0.031) and ΔvaultP1M-P1D (P=0.005) correlated significantly with Δvault P3M-P1M. Conclusions: Haptics inserted in the ciliary body are more susceptible to positional shifts. Increased IRH is more likely to occur in eyes with a thinner ciliary body, thinner iris, and wider TCA.
- 5 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (10) , 903-908
Short-term Change in Haptic position of Implantable Collamer Lenses and its correlation with the variation of vault
Purpose: To examine changes in the haptic position of the implantable collamer lens (ICL) within the postoperative3 months and its correlation with vault variation. Setting: Eye and ENT Hospital, Fudan University, Shanghai, China. Design: Prospective non-randomized study. Methods: This study included 58 right eyes of 58 patients who underwent ICL implantation for the correction of myopia or myopic astigmatism. The position of the ICL haptic was measured using ultrasound biomicroscopy (UBM) at postoperative 1 month (P1M) and 3 months (P3M) and was classified into three types: haptic in the ciliary sulcus (ICS), haptic in the ciliary body (ICB), and haptic under the ciliary body (UCB). Results: Among haptics classified as ICS at P1M (n=131), 120 remained ICS (91.60%), 9 became ICB (6.87%), and 2 became UCB (1.53%) at P3M. Among haptics classified as ICB at P1M (n=66), 44 remained ICB (66.67%), 17 became ICS (25.76%), and 5 became UCB (7.58%). Among haptics classified as UCB at P1M (n=35), 26 remained UCB (74.29%) and 9 became ICB (25.71%). The maximum ciliary body thickness (CBTmax, P=0.010), iris thickness at 500 μm (IT500, P=0.029), and trabecular-ciliary angle (TCA, P=0.045) were associated with ΔIRHP3M-P1M (distance between the iris root and the tip of haptic, P3M-P1M). Anterior chamber depth (ACD, P=0.031) and ΔvaultP1M-P1D (P=0.005) correlated significantly with Δvault P3M-P1M. Conclusions: Haptics inserted in the ciliary body are more susceptible to positional shifts. Increased IRH is more likely to occur in eyes with a thinner ciliary body, thinner iris, and wider TCA.
- Open Access
- 28 May 2025
- Published by Springer Nature in Eye and Vision
- Vol. 12 (1) , 1-10
The effects of fixation stability, corneal density, and epithelial hyperplasia on the efficacy of astigmatism correction by transepithelial photorefractive keratectomy
Background: Transepithelial photorefractive keratectomy (transPRK) can be safely and predictably performed to correct low-to-high astigmatism. This study explored the effects of fixation stability, corneal density (CD), ocular residual astigmatism (ORA), and the surgically-induced change in the epithelial thickness (ΔET) on the efficacy of astigmatism correction by transPRK. Methods: Eighty-three consecutive patients who underwent transPRK to correct myopia and myopic astigmatism were divided into two groups according to refractive astigmatism [high refractive astigmatism (RA) group: ≥ 2.0 D, n = 31; low RA group: < 2.0 D, n = 52]. Fixation stability was evaluated by measuring the lateral movement of the pupil center on the eye tracker images. The CD was measured using a Pentacam Scheimpflug imaging system, epithelial thickness mapping was performed using optical coherence tomography, and the ORA was determined using vector analysis. Multiple linear regression analyses were performed to identify factors associated with the correction index (CI) and angle of error (AOE). Results: At 6 months postoperatively, the RA was higher in the high RA group (− 0.66 ± 0.44 D) than in the low RA group (− 0.29 ± 0.29 D, P < 0.001), whereas no significant differences were found in CI or AOE between two groups. Multiple linear regression analyses showed that for the low RA group, preoperative anterior CD of the central 2 mm (CD0-2A, β = − 0.482, P = 0.011) and ΔET (β = 0.295, P = 0.041), were associated with CI, whereas the vector length of the pupil center shift (PCVL, β = − 0.404, P = 0.005) and ΔET (β = − 0.293, P = 0.036) were associated with AOE. For the high RA group, ΔET (β = 0.519, P = 0.038) was associated with CI, whereas static cyclotorsion (β = − 0.493, P = 0.040) was associated with AOE. No significant associations were found between ORA and CI or AOE. Conclusions: Postoperative changes in epithelial thickness were associated with the efficacy of transPRK in both the low and high RA groups, whereas the pupil center shift and anterior CD were associated with the efficacy of transPRK in the low RA group.
- 28 May 2025
- Published by Springer Nature in Eye and Vision
- Vol. 12 (1) , 1-10
Open AccessThe effects of fixation stability, corneal density, and epithelial hyperplasia on the efficacy of astigmatism correction by transepithelial photorefractive keratectomy
Background: Transepithelial photorefractive keratectomy (transPRK) can be safely and predictably performed to correct low-to-high astigmatism. This study explored the effects of fixation stability, corneal density (CD), ocular residual astigmatism (ORA), and the surgically-induced change in the epithelial thickness (ΔET) on the efficacy of astigmatism correction by transPRK. Methods: Eighty-three consecutive patients who underwent transPRK to correct myopia and myopic astigmatism were divided into two groups according to refractive astigmatism [high refractive astigmatism (RA) group: ≥ 2.0 D, n = 31; low RA group: < 2.0 D, n = 52]. Fixation stability was evaluated by measuring the lateral movement of the pupil center on the eye tracker images. The CD was measured using a Pentacam Scheimpflug imaging system, epithelial thickness mapping was performed using optical coherence tomography, and the ORA was determined using vector analysis. Multiple linear regression analyses were performed to identify factors associated with the correction index (CI) and angle of error (AOE). Results: At 6 months postoperatively, the RA was higher in the high RA group (− 0.66 ± 0.44 D) than in the low RA group (− 0.29 ± 0.29 D, P < 0.001), whereas no significant differences were found in CI or AOE between two groups. Multiple linear regression analyses showed that for the low RA group, preoperative anterior CD of the central 2 mm (CD0-2A, β = − 0.482, P = 0.011) and ΔET (β = 0.295, P = 0.041), were associated with CI, whereas the vector length of the pupil center shift (PCVL, β = − 0.404, P = 0.005) and ΔET (β = − 0.293, P = 0.036) were associated with AOE. For the high RA group, ΔET (β = 0.519, P = 0.038) was associated with CI, whereas static cyclotorsion (β = − 0.493, P = 0.040) was associated with AOE. No significant associations were found between ORA and CI or AOE. Conclusions: Postoperative changes in epithelial thickness were associated with the efficacy of transPRK in both the low and high RA groups, whereas the pupil center shift and anterior CD were associated with the efficacy of transPRK in the low RA group.
- Open Access
- 10 February 2025
- Published by Springer Nature in BMC Ophthalmology
- Vol. 25 (1) , 1-8
Tomographic characteristics of thick corneas
To investigate the tomographic characteristics of corneas with excessive thickness and to explore their potential impact on the assessment of candidates for refractive surgery. One hundred and two eyes from 102 patients with the thinnest pachymetry (TP) < 500 μm, 100 eyes from 100 patients with TP ranging from 500 to 580 μm, and 102 eyes from 102 subjects with TP ≥ 580 μm were included. Pentacam ectasia indices were compared among these different groups. When compared to eyes with TP between 500 and 580 μm, significantly higher values in anterior radius of curvature (ARC), anterior corneal astigmatism (KAp), back elevation at the thinnest pachymetry (BE), deviation of normality of the back elevation (Db), and a more negative Q value for the back surface (Qback) were observed in eyes with TP ≥ 580 μm (Mann-Whitney U test: P < 0.001). No significant differences were observed in the indices for the anterior cornea (Mann-Whitney U test: index of height decentration, P = 0.348; inferior-superior value, P = 0.334; keratoconus percentage index, P = 0.077; deviation of normality of the front elevation, P = 0.891). The proportion of abnormalities was highest in eyes with TP ≥ 580 μm for BE (16.7%, Chi-square test: P < 0.001) and Db (20.6%, Chi-square test: P = 0.001). The tomography of thick corneas reveals greater BE and Db, as well as a more negative Qback while no significant disparities emerged in the anterior corneal indices.
- 10 February 2025
- Published by Springer Nature in BMC Ophthalmology
- Vol. 25 (1) , 1-8
Open AccessTomographic characteristics of thick corneas
To investigate the tomographic characteristics of corneas with excessive thickness and to explore their potential impact on the assessment of candidates for refractive surgery. One hundred and two eyes from 102 patients with the thinnest pachymetry (TP) < 500 μm, 100 eyes from 100 patients with TP ranging from 500 to 580 μm, and 102 eyes from 102 subjects with TP ≥ 580 μm were included. Pentacam ectasia indices were compared among these different groups. When compared to eyes with TP between 500 and 580 μm, significantly higher values in anterior radius of curvature (ARC), anterior corneal astigmatism (KAp), back elevation at the thinnest pachymetry (BE), deviation of normality of the back elevation (Db), and a more negative Q value for the back surface (Qback) were observed in eyes with TP ≥ 580 μm (Mann-Whitney U test: P < 0.001). No significant differences were observed in the indices for the anterior cornea (Mann-Whitney U test: index of height decentration, P = 0.348; inferior-superior value, P = 0.334; keratoconus percentage index, P = 0.077; deviation of normality of the front elevation, P = 0.891). The proportion of abnormalities was highest in eyes with TP ≥ 580 μm for BE (16.7%, Chi-square test: P < 0.001) and Db (20.6%, Chi-square test: P = 0.001). The tomography of thick corneas reveals greater BE and Db, as well as a more negative Qback while no significant disparities emerged in the anterior corneal indices.
- Open Access
- 7 March 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-10
Measurement of the distance between corneal apex and pupil center in patients following small-incision lenticule extraction or implantable collamer lens implantation and its correlation with the surgical-induced astigmatism
Background: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). Methods: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ( $$ \sqrt{{X}^{2}+{Y}^{2}}@ $$ orientation), and was compared pre- and post-operative. Results: Following SMILE, the magnitude of chord u $$ (\sqrt{{X}^{2}+{Y}^{2}}$$ ) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). Conclusions: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u.- 7 March 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-10
Open AccessMeasurement of the distance between corneal apex and pupil center in patients following small-incision lenticule extraction or implantable collamer lens implantation and its correlation with the surgical-induced astigmatism
Background: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). Methods: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ( $$ \sqrt{{X}^{2}+{Y}^{2}}@ $$ orientation), and was compared pre- and post-operative. Results: Following SMILE, the magnitude of chord u $$ (\sqrt{{X}^{2}+{Y}^{2}}$$ ) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). Conclusions: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u. - Open Access
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (3) , 276-282
Risk factors associated with haptic malposition in eyes implanted with implantable collamer lenses
Purpose: To examine the risk factors for haptic malposition in eyes with implantable collamer lens (ICL). Setting: Eye and ENT Hospital, Fudan University, Shanghai, China. Design: Prospective nonrandomized observational study. Methods: This study included 134 (77.9%) of 172 initially enrolled patients who underwent ICL implantation and completed a 1-year follow-up. The extent of haptics present in the ciliary sulcus (ICS) was measured. Patients were categorized based on ICS count (0 to 4). The position of the haptics was quantified as the distance between the iris root and the terminal tip of ICL haptics (iris root to haptic tip, IRH). The related factors to the ICS count and its correlation with the central vault were analyzed. Results: ICS distribution was 0 ICS in 19 eyes (14.2%), 1 in 22 eyes (16.4%), 2 in 32 eyes (23.9%), 3 in 29 eyes (21.6%), and 4 in 32 eyes (23.9%). Parameters like maximum ciliary body thickness (CBTmax, P = .008), iris–ciliary process distance (ICPD, P < .001), and ciliary process length (P = .034) varied significantly across ICS groups. A multiple linear regression analysis revealed that the iris–ciliary angle (P = .006), CBTmax (P = .007), the distance between the sulcus-to-sulcus plane and the anterior crystalline lens surface (STSL, P = .035), and ICL size (P = .015) were significantly associated with IRH. Spherical equivalents (P = .042), STSL (P = .001), and ICS count (P = .020) significantly correlated with the central vault. Conclusions: Shortened ciliary process is a primary risk for haptic malposition. The ICS count significantly relates to the central vault.
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (3) , 276-282
Open AccessRisk factors associated with haptic malposition in eyes implanted with implantable collamer lenses
Purpose: To examine the risk factors for haptic malposition in eyes with implantable collamer lens (ICL). Setting: Eye and ENT Hospital, Fudan University, Shanghai, China. Design: Prospective nonrandomized observational study. Methods: This study included 134 (77.9%) of 172 initially enrolled patients who underwent ICL implantation and completed a 1-year follow-up. The extent of haptics present in the ciliary sulcus (ICS) was measured. Patients were categorized based on ICS count (0 to 4). The position of the haptics was quantified as the distance between the iris root and the terminal tip of ICL haptics (iris root to haptic tip, IRH). The related factors to the ICS count and its correlation with the central vault were analyzed. Results: ICS distribution was 0 ICS in 19 eyes (14.2%), 1 in 22 eyes (16.4%), 2 in 32 eyes (23.9%), 3 in 29 eyes (21.6%), and 4 in 32 eyes (23.9%). Parameters like maximum ciliary body thickness (CBTmax, P = .008), iris–ciliary process distance (ICPD, P < .001), and ciliary process length (P = .034) varied significantly across ICS groups. A multiple linear regression analysis revealed that the iris–ciliary angle (P = .006), CBTmax (P = .007), the distance between the sulcus-to-sulcus plane and the anterior crystalline lens surface (STSL, P = .035), and ICL size (P = .015) were significantly associated with IRH. Spherical equivalents (P = .042), STSL (P = .001), and ICS count (P = .020) significantly correlated with the central vault. Conclusions: Shortened ciliary process is a primary risk for haptic malposition. The ICS count significantly relates to the central vault.
- Open Access
- 16 January 2024
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (8) , 788-794
Influence of corneal diameter on the accuracy of corneal tomography in patients with forme fruste keratoconus or thin corneas
The detection of subclinical ectasia is important in preoperative screening for laser-refractive surgery. Previous studies have confirmed the impact of corneal diameter on the diagnostic accuracy of several ectasia indices in tomographically normal eyes. This study aimed to investigate the influence of corneal diameter on the diagnostic accuracy of Pentacam tomographic indices in eyes with forme fruste keratoconus (FFKC) and thin corneas. One hundred and one eyes of 101 patients with FFKC (FFKC group), 104 eyes of 104 patients with a corneal thickness p < 0.001). Comparing for the classifications (normal versus abnormal) of the individual indices demonstrated that for corneal diameters ≤11.9 mm, the rates of abnormal cases were significantly higher in the FFKC group than in the normal group for seven indices and in the thin cornea group than normal group for nine indices. For corneal diameters >11.9 mm, the rates of abnormal cases were higher in the FFKC than normal group for three indices and higher in the thin cornea group than normal group for seven indices. Belin/Ambrosio Enhanced Ectasia display indices may underestimate the risk of ectasia in patients with large corneas, especially those with FFKC.
- 16 January 2024
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (8) , 788-794
Open AccessInfluence of corneal diameter on the accuracy of corneal tomography in patients with forme fruste keratoconus or thin corneas
The detection of subclinical ectasia is important in preoperative screening for laser-refractive surgery. Previous studies have confirmed the impact of corneal diameter on the diagnostic accuracy of several ectasia indices in tomographically normal eyes. This study aimed to investigate the influence of corneal diameter on the diagnostic accuracy of Pentacam tomographic indices in eyes with forme fruste keratoconus (FFKC) and thin corneas. One hundred and one eyes of 101 patients with FFKC (FFKC group), 104 eyes of 104 patients with a corneal thickness p < 0.001). Comparing for the classifications (normal versus abnormal) of the individual indices demonstrated that for corneal diameters ≤11.9 mm, the rates of abnormal cases were significantly higher in the FFKC group than in the normal group for seven indices and in the thin cornea group than normal group for nine indices. For corneal diameters >11.9 mm, the rates of abnormal cases were higher in the FFKC than normal group for three indices and higher in the thin cornea group than normal group for seven indices. Belin/Ambrosio Enhanced Ectasia display indices may underestimate the risk of ectasia in patients with large corneas, especially those with FFKC.
- Open Access
- 1 November 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 3569-3577
Assessment of Keratoconus Risk in Very Asymmetric Ectasia Using Corneal Tomographic and Biomechanical Parameters
Purpose: To investigate the relationship between corneal tomographic or biomechanical parameters and risk of keratoconus in very asymmetric ectasia (VAE). Methods: This retrospective case-control single-centre study included patients with VAE and normal controls. The VAE group had clinical ectasia in one eye and normal topography (VAE-NT) in the fellow eye; VAE-NT eyes were selected for analysis. The control group was selected from corneal refractive surgery candidates; the right eye was enrolled. Scheimpflug-based corneal tomography (Pentacam) and corneal biomechanical assessment (Corvis ST) were performed. Univariate and multivariable logistic regression were performed using Cox proportional hazards models to evaluate keratoconus-associated risk factors. A two-piecewise linear regression model was applied to examine the threshold effect of selected vital paragmeters on the risk of keratoconus according to a smoothing plot. Results: Threshold effect between tomographic integration and risk of keratoconus was observed. Discrepancy between the central corneal thickness and thinnest corneal thickness (discrepancy CCT vs TCT) greater than 5 μm, discrepancy between the apex corneal thickness and thinnest corneal thickness (discrepancy ACT vs TCT) greater than 3 μm, vector distance between CCT and TCT (distance CCT vs TCT) greater than 0.65 mm indicated a significant increased risk of keratoconus. Risk of keratoconus decreased when distance CCT vs TCT was less than 0.65 mm. Conclusion: Discrepancy CCT vs TCT, discrepancy ACT vs TCT, and distance CCT vs TCT can be used as indicators for risk assessment of early keratoconus.
- 1 November 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 3569-3577
Open AccessAssessment of Keratoconus Risk in Very Asymmetric Ectasia Using Corneal Tomographic and Biomechanical Parameters
Purpose: To investigate the relationship between corneal tomographic or biomechanical parameters and risk of keratoconus in very asymmetric ectasia (VAE). Methods: This retrospective case-control single-centre study included patients with VAE and normal controls. The VAE group had clinical ectasia in one eye and normal topography (VAE-NT) in the fellow eye; VAE-NT eyes were selected for analysis. The control group was selected from corneal refractive surgery candidates; the right eye was enrolled. Scheimpflug-based corneal tomography (Pentacam) and corneal biomechanical assessment (Corvis ST) were performed. Univariate and multivariable logistic regression were performed using Cox proportional hazards models to evaluate keratoconus-associated risk factors. A two-piecewise linear regression model was applied to examine the threshold effect of selected vital paragmeters on the risk of keratoconus according to a smoothing plot. Results: Threshold effect between tomographic integration and risk of keratoconus was observed. Discrepancy between the central corneal thickness and thinnest corneal thickness (discrepancy CCT vs TCT) greater than 5 μm, discrepancy between the apex corneal thickness and thinnest corneal thickness (discrepancy ACT vs TCT) greater than 3 μm, vector distance between CCT and TCT (distance CCT vs TCT) greater than 0.65 mm indicated a significant increased risk of keratoconus. Risk of keratoconus decreased when distance CCT vs TCT was less than 0.65 mm. Conclusion: Discrepancy CCT vs TCT, discrepancy ACT vs TCT, and distance CCT vs TCT can be used as indicators for risk assessment of early keratoconus.
- Open Access
- 14 February 2023
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (2) , 1195-1206
Anterior Segment Characteristics of Eyes with Anterior Chamber Depth Less than 2.8 mm and Axial Length Greater than 25 mm
Introduction This study aimed to investigate anterior segment parameters of eyes, with anterior chamber depth (ACD) less than 2.8 mm and axial length greater than 25.0 mm. Methods This cross-sectional study included 180 myopic eyes of 180 consecutive patients with axial length greater than 25.0 mm. Patients were divided into low ACD (ACD < 2.8 mm, n = 56) and normal ACD (ACD ≥ 2.8 mm, n = 124) groups. Anterior segment parameters were measured using Scheimpflug imaging and ultrasound biomicroscopy. A general linear model was used to compare parameters between the two groups, after adjusting for age and spherical equivalent. Results Compared with the normal ACD group, the low ACD group had lower values for the following parameters: corneal diameter, trabecular–anterior iris surface angle, angle-opening distance at 500 μm, anterior chamber volume, anterior chamber width, anterior vault, iris thickness at 500 μm, ciliary sulcus-to-sulcus diameter, distance between cornea and sulcus, trabecular–ciliary process distance, maximum ciliary body thickness, ciliary process length, relative anterior vault, relative distance between cornea and sulcus, and relative lens position (general linear model, p < 0.05). In contrast, central corneal thickness, iris curvature, lens thickness, lens vault, and iris–ciliary angle were greater in the low ACD group (general linear model, p < 0.05). Conclusion A smaller anterior segment, as well as a thicker and more anteriorly positioned lens, may correlate with shallow ACD in eyes with long axial length.
- 14 February 2023
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (2) , 1195-1206
Open AccessAnterior Segment Characteristics of Eyes with Anterior Chamber Depth Less than 2.8 mm and Axial Length Greater than 25 mm
Introduction This study aimed to investigate anterior segment parameters of eyes, with anterior chamber depth (ACD) less than 2.8 mm and axial length greater than 25.0 mm. Methods This cross-sectional study included 180 myopic eyes of 180 consecutive patients with axial length greater than 25.0 mm. Patients were divided into low ACD (ACD < 2.8 mm, n = 56) and normal ACD (ACD ≥ 2.8 mm, n = 124) groups. Anterior segment parameters were measured using Scheimpflug imaging and ultrasound biomicroscopy. A general linear model was used to compare parameters between the two groups, after adjusting for age and spherical equivalent. Results Compared with the normal ACD group, the low ACD group had lower values for the following parameters: corneal diameter, trabecular–anterior iris surface angle, angle-opening distance at 500 μm, anterior chamber volume, anterior chamber width, anterior vault, iris thickness at 500 μm, ciliary sulcus-to-sulcus diameter, distance between cornea and sulcus, trabecular–ciliary process distance, maximum ciliary body thickness, ciliary process length, relative anterior vault, relative distance between cornea and sulcus, and relative lens position (general linear model, p < 0.05). In contrast, central corneal thickness, iris curvature, lens thickness, lens vault, and iris–ciliary angle were greater in the low ACD group (general linear model, p < 0.05). Conclusion A smaller anterior segment, as well as a thicker and more anteriorly positioned lens, may correlate with shallow ACD in eyes with long axial length.