Abstract
This study presents a simulation-based engineering comparison of three-phase and asymmetrical six-phase induction traction drives for DC-electrified conventional railway duty. Both drive models were implemented in MATLAB/Simulink using the same base machine data, DC-link voltage, inertia, and piecewise variable load torque so that the influence of drive topology and implementation could be examined under matched operating conditions. Scalar V/f control was used in both cases, and the compared outputs were current waveforms, electromagnetic torque, rotor speed, and FFT-derived harmonic distortion. The six-phase drive produced a higher reported torque metric (14.22 versus 7.649), while the three-phase drive reached the higher reported speed (1818 versus 689.2). The harmonic results showed a trade-off: rotor-current THD was lower in the six-phase implementation (379.41% versus 633.72%), whereas stator-current THD was higher (220.99% versus 10.77%). Additional waveform evidence showed that the six-phase architecture remained more torque-oriented under the variable load schedule, which is attractive for low-speed traction duty. Overall, the results indicate that asymmetrical six-phase induction drives are promising for railway applications prioritizing low-speed torque capability and robustness, while further control optimization is needed to reduce stator-side harmonic burden.