Maurice Twizerimana
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maurice Twizerimana has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Abid Khan
Health Department, Government of Sindh Karachi, Pakistan
1 shared publicationAdeel Arsalan
Department of Pharmaceutics, Faculty of Pharmacy, Ziauddin University, Karachi, Pakistan
1 shared publicationAiman Syed
Karachi Medical and Dental College, Karachi, Pakistan
1 shared publicationAlexis Bakundukize
African Centre of Excellence in Energy for Sustainable Development (ACE-ESD), College of Science and Technology, University of Rwanda, Kigali, Rwanda
1 shared publicationBizabakoraho Jean Pierre
African Centre of Excellence in Energy for Sustainable Development (ACE-ESD), College of Science and Technology, University of Rwanda, Kigali, Rwanda
1 shared publicationBushra Imtiaz Ali
Karachi Medical and Dental College, Karachi, Pakistan
1 shared publication
Latest Publications
- Open Access
- 10 April 2026
- Published by Elsevier in SSRN Electronic Journal
Simulation-Based Dynamic and Harmonic Comparison of Three-Phase and Asymmetrical Six-Phase Induction Drives for DC Railway Traction Under Variable Load
This study presents a simulation-based engineering comparison of three-phase and asymmetrical six-phase induction traction drives for DC-electrified conventional railway duty. Both drive models were implemented in MATLAB/Simulink using the same base machine data, DC-link voltage, inertia, and piecewise variable load torque so that the influence of drive topology and implementation could be examined under matched operating conditions. Scalar V/f control was used in both cases, and the compared outputs were current waveforms, electromagnetic torque, rotor speed, and FFT-derived harmonic distortion. The six-phase drive produced a higher reported torque metric (14.22 versus 7.649), while the three-phase drive reached the higher reported speed (1818 versus 689.2). The harmonic results showed a trade-off: rotor-current THD was lower in the six-phase implementation (379.41% versus 633.72%), whereas stator-current THD was higher (220.99% versus 10.77%). Additional waveform evidence showed that the six-phase architecture remained more torque-oriented under the variable load schedule, which is attractive for low-speed traction duty. Overall, the results indicate that asymmetrical six-phase induction drives are promising for railway applications prioritizing low-speed torque capability and robustness, while further control optimization is needed to reduce stator-side harmonic burden.
- 10 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSimulation-Based Dynamic and Harmonic Comparison of Three-Phase and Asymmetrical Six-Phase Induction Drives for DC Railway Traction Under Variable Load
This study presents a simulation-based engineering comparison of three-phase and asymmetrical six-phase induction traction drives for DC-electrified conventional railway duty. Both drive models were implemented in MATLAB/Simulink using the same base machine data, DC-link voltage, inertia, and piecewise variable load torque so that the influence of drive topology and implementation could be examined under matched operating conditions. Scalar V/f control was used in both cases, and the compared outputs were current waveforms, electromagnetic torque, rotor speed, and FFT-derived harmonic distortion. The six-phase drive produced a higher reported torque metric (14.22 versus 7.649), while the three-phase drive reached the higher reported speed (1818 versus 689.2). The harmonic results showed a trade-off: rotor-current THD was lower in the six-phase implementation (379.41% versus 633.72%), whereas stator-current THD was higher (220.99% versus 10.77%). Additional waveform evidence showed that the six-phase architecture remained more torque-oriented under the variable load schedule, which is attractive for low-speed traction duty. Overall, the results indicate that asymmetrical six-phase induction drives are promising for railway applications prioritizing low-speed torque capability and robustness, while further control optimization is needed to reduce stator-side harmonic burden.
- Open Access
- 15 March 2022
- Published by Taylor & Francis
- p. 202-209
Production of biogas from sized cotton yarn wastes
Solid waste management is among the environmental challenges facing many industries in the world today. Biogas production is one of the most cost-efficient renewable energy technologies that use biodegradable wastes as feedstock. Furthermore, it is one of the methods for reducing greenhouse gas emission. Cotton Yarn Wastes (CYW) is among the biodegradable wastes that are commonly managed by dumping onto the open land or disposing in sanitary landfills where they undergo anaerobic decomposition. However, CYW could be used as substrate to generate energy in the form of biogas that can be utilized in other activities like powering textiles production. The aim of this study was to investigate the use of CYW as a substrate for biogas production using anaerobic batch reactor. The experiment was carried out in reactors of two-liter capacity. The CYW and inoculum were characterized before and after digestion. The CYW contained 93.18% total solids, 82.48% total volatile solids and 6.82% moisture content while the respective values for digested sludge were 21.61%, 23.61% and 78.38%, respectively. The carbon to nitrogen (C/N) ratio of inoculum was 20.5, which is in the suitable range to keep the anaerobic digestion in a stable condition. However, the CYW had high carbon content; resulting in a C/N ratio of 42.5. The effect of TS concentration at different ratios of CYW on biogas volume produced was investigated. The reactors loading was differentiated using a mixture with concentration corresponding to R1 (1:1), R2 (1:1.5), R3 (1:2), R4 (1:2.5), R5 (1:3), R6 (1:3.5), R7 (1:4), R8 (1:5), R9 (1:6), and R10 (1:10) on TS content basis i.e. 50%, 40%, 33%, 28%, 25%, 22%, 20%, 18%, 14%, and 10% respectively. The total biogas yield was 6307 mL, 6519 mL, 6711 mL, 7178 mL, 4878 mL, 3868 mL, 3720 mL, 3306 mL, 1164 mL, and 932 mL respectively after 36 days. The results indicated that biogas production increased with increase in TS content. The ratio that provided 28% of TS content had the highest biogas yield. The average reduced TVS at the end of digestion was 88.49%. The results of this test indicated that CYW is a suitable substrate for AD due to its high biodegradability. Therefore, the reactors should run at 28% TS, for maximum biogas generation.
- 15 March 2022
- Published by Taylor & Francis
- p. 202-209
Open AccessProduction of biogas from sized cotton yarn wastes
Solid waste management is among the environmental challenges facing many industries in the world today. Biogas production is one of the most cost-efficient renewable energy technologies that use biodegradable wastes as feedstock. Furthermore, it is one of the methods for reducing greenhouse gas emission. Cotton Yarn Wastes (CYW) is among the biodegradable wastes that are commonly managed by dumping onto the open land or disposing in sanitary landfills where they undergo anaerobic decomposition. However, CYW could be used as substrate to generate energy in the form of biogas that can be utilized in other activities like powering textiles production. The aim of this study was to investigate the use of CYW as a substrate for biogas production using anaerobic batch reactor. The experiment was carried out in reactors of two-liter capacity. The CYW and inoculum were characterized before and after digestion. The CYW contained 93.18% total solids, 82.48% total volatile solids and 6.82% moisture content while the respective values for digested sludge were 21.61%, 23.61% and 78.38%, respectively. The carbon to nitrogen (C/N) ratio of inoculum was 20.5, which is in the suitable range to keep the anaerobic digestion in a stable condition. However, the CYW had high carbon content; resulting in a C/N ratio of 42.5. The effect of TS concentration at different ratios of CYW on biogas volume produced was investigated. The reactors loading was differentiated using a mixture with concentration corresponding to R1 (1:1), R2 (1:1.5), R3 (1:2), R4 (1:2.5), R5 (1:3), R6 (1:3.5), R7 (1:4), R8 (1:5), R9 (1:6), and R10 (1:10) on TS content basis i.e. 50%, 40%, 33%, 28%, 25%, 22%, 20%, 18%, 14%, and 10% respectively. The total biogas yield was 6307 mL, 6519 mL, 6711 mL, 7178 mL, 4878 mL, 3868 mL, 3720 mL, 3306 mL, 1164 mL, and 932 mL respectively after 36 days. The results indicated that biogas production increased with increase in TS content. The ratio that provided 28% of TS content had the highest biogas yield. The average reduced TVS at the end of digestion was 88.49%. The results of this test indicated that CYW is a suitable substrate for AD due to its high biodegradability. Therefore, the reactors should run at 28% TS, for maximum biogas generation.
- 5 May 2021
- Published by Sciencedomain International in Journal of Energy Research and Reviews
- p. 31-55
Design and Modelling of PV Power Plant for Rural Electrification in Kayonza, Rwanda
Aims: This study aimed to design and model an off-grid SPV power plant with a storage system to meet the load required in Rwisirabo village. Study Design: PV modules, inverter, charge controller, and Batteries have been designed, reproduced/simulated, and optimized for the rural area of Rwisirabo village in Kayonza district, Eastern Province, Rwanda. Place and Duration of Study: The experiment has been done in the University of Rwanda/ African Centre of Excellence in Energy Studies for Sustainable Development (UR/ACE-ESD) High E-Tech Smart Grid Laboratory, Kigali, Rwanda between October 2020 and February 2021. Methodology: Different methodologies have been applied to address the objective of this work. The site was identified, problems of the community were clearly stated, data required for the work was collected through various data collection mechanisms, and different literature was reviewed to identify the way to do this work. The data were collected from different sources and were analysed using a software tool (HOMER software) and simulated for getting a solution for the problems and challenged accordingly. An Off-grid Solar Photovoltaic Power Plant was established in Rwisirabo village in Kayonza District, Rwanda. This site has been chosen because, in the Mwiri sector, Kageyo cellule in Rwisirabo (Rwisirabo II) village is listed by National Electrification Plan (NEP) as the site to construct an off-grid solar PV Power Plant. Results: Based on the load assessment and the design of the SPV system, the primary AC load of the village was 551,718 kWh/day with a peak load of 85.10 kW, the deferrable load was about 9.99 kWh/day and a deferrable peak load of 2.00 kW with the cost of energy (COE) $0.200/kWh were involved during optimization of the power plant. It also found that the peak demand of the community occurs from 18:00 to 20:00 hours because most of the household members would expect to be at their homes. The system items such as PV module, batteries, and inverter size have been found as an optimum system with 220 kW, 860 BAE PVS 210 batteries, and 110 kW respectively with a lifespan of 25 years of the project. The total net present cost (NPC), initial capital, operating cost, and Levelized COE for this off-grid SPV system were $903,829, $517,000, $17,522, and $0.200/kWh respectively. The monthly results of power generation in kW obtained after stimulation with software showed that the solar radiation is high in March, July, August, and September which brings more electric power generation. However, all months the power electricity remain generated. Results from simulation showed that this system generated mean power output of 220 kW and total production of 297,291 kWh/year. It approved that the system converter contributed the lowest NPC with $52,888.25 (6%), followed by PV modules that cost $244,284.28 (27%) and battery bank the first for this SPV system with a cost of $606,656.60 (67%). This optimal system uses 100% renewable energy. Conclusion: It found that the implementation of an SPV system with battery storage in residential, commercial, and institutions in the area where the solar irradiance is concentrated across a country will reduce the cost of electricity and power interruption on the national grid. Therefore, further work is needed to optimize this system for rural electrification as well by integrating with other renewable sources available in the country and also extend the electrification to another area that is detached from the national grid.
- 5 May 2021
- Published by Sciencedomain International in Journal of Energy Research and Reviews
- p. 31-55
Design and Modelling of PV Power Plant for Rural Electrification in Kayonza, Rwanda
Aims: This study aimed to design and model an off-grid SPV power plant with a storage system to meet the load required in Rwisirabo village. Study Design: PV modules, inverter, charge controller, and Batteries have been designed, reproduced/simulated, and optimized for the rural area of Rwisirabo village in Kayonza district, Eastern Province, Rwanda. Place and Duration of Study: The experiment has been done in the University of Rwanda/ African Centre of Excellence in Energy Studies for Sustainable Development (UR/ACE-ESD) High E-Tech Smart Grid Laboratory, Kigali, Rwanda between October 2020 and February 2021. Methodology: Different methodologies have been applied to address the objective of this work. The site was identified, problems of the community were clearly stated, data required for the work was collected through various data collection mechanisms, and different literature was reviewed to identify the way to do this work. The data were collected from different sources and were analysed using a software tool (HOMER software) and simulated for getting a solution for the problems and challenged accordingly. An Off-grid Solar Photovoltaic Power Plant was established in Rwisirabo village in Kayonza District, Rwanda. This site has been chosen because, in the Mwiri sector, Kageyo cellule in Rwisirabo (Rwisirabo II) village is listed by National Electrification Plan (NEP) as the site to construct an off-grid solar PV Power Plant. Results: Based on the load assessment and the design of the SPV system, the primary AC load of the village was 551,718 kWh/day with a peak load of 85.10 kW, the deferrable load was about 9.99 kWh/day and a deferrable peak load of 2.00 kW with the cost of energy (COE) $0.200/kWh were involved during optimization of the power plant. It also found that the peak demand of the community occurs from 18:00 to 20:00 hours because most of the household members would expect to be at their homes. The system items such as PV module, batteries, and inverter size have been found as an optimum system with 220 kW, 860 BAE PVS 210 batteries, and 110 kW respectively with a lifespan of 25 years of the project. The total net present cost (NPC), initial capital, operating cost, and Levelized COE for this off-grid SPV system were $903,829, $517,000, $17,522, and $0.200/kWh respectively. The monthly results of power generation in kW obtained after stimulation with software showed that the solar radiation is high in March, July, August, and September which brings more electric power generation. However, all months the power electricity remain generated. Results from simulation showed that this system generated mean power output of 220 kW and total production of 297,291 kWh/year. It approved that the system converter contributed the lowest NPC with $52,888.25 (6%), followed by PV modules that cost $244,284.28 (27%) and battery bank the first for this SPV system with a cost of $606,656.60 (67%). This optimal system uses 100% renewable energy. Conclusion: It found that the implementation of an SPV system with battery storage in residential, commercial, and institutions in the area where the solar irradiance is concentrated across a country will reduce the cost of electricity and power interruption on the national grid. Therefore, further work is needed to optimize this system for rural electrification as well by integrating with other renewable sources available in the country and also extend the electrification to another area that is detached from the national grid.
- 5 May 2021
- Published by Sciencedomain International in Journal of Pharmaceutical Research International
- Vol. 33 (28A) , 169-173
Counseling Practices of Pharmacists at Medical Stores/Pharmacies in Karachi Pakistan
Introduction: Dispensing medicines means delivering complete knowledge about the medicine being dispensed to that patient. Patient’s counseling regarding their medications play a very important role to achieve the high efficacy and proper constancy on therapy. The aim of the study was to evaluate the counseling practices of pharmacist from customers’ perspective. Methodology: This was a descriptive cross sectional study, conducted among who were selected at random at pharmacies/ medical stores, while purchasing medications for them and/or for their loved ones. The study finally included 365 patients or attendants of the patients. The data obtained were analyzed using appropriate statistical analysis through SPPS version 25. Results: 289 (81.37%) patients were counseled when they purchased antibiotics about the completion of the therapy and to take the doses timely. Only 4 patients were told about missing a dose. Conclusion: There were different results of candidates majority of them were satisfied with on-going pharmacy service but some were not. Candidates also told about the lack of information given by the health care professional /pharmacist prior to dispensing.
- 5 May 2021
- Published by Sciencedomain International in Journal of Pharmaceutical Research International
- Vol. 33 (28A) , 169-173
Counseling Practices of Pharmacists at Medical Stores/Pharmacies in Karachi Pakistan
Introduction: Dispensing medicines means delivering complete knowledge about the medicine being dispensed to that patient. Patient’s counseling regarding their medications play a very important role to achieve the high efficacy and proper constancy on therapy. The aim of the study was to evaluate the counseling practices of pharmacist from customers’ perspective. Methodology: This was a descriptive cross sectional study, conducted among who were selected at random at pharmacies/ medical stores, while purchasing medications for them and/or for their loved ones. The study finally included 365 patients or attendants of the patients. The data obtained were analyzed using appropriate statistical analysis through SPPS version 25. Results: 289 (81.37%) patients were counseled when they purchased antibiotics about the completion of the therapy and to take the doses timely. Only 4 patients were told about missing a dose. Conclusion: There were different results of candidates majority of them were satisfied with on-going pharmacy service but some were not. Candidates also told about the lack of information given by the health care professional /pharmacist prior to dispensing.