Comparison of Cylindrical and Tapered Stem Designs for Femoral Revision Hip Arthroplasty
Open Access
- 18 March 2024
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (6) , 1745
Abstract
Background: Cylindrical fully-coated cobalt-chromium stems (CCS) have been widely used in femoral revisions. However, monoblock fluted conical tapered stems (FCTS) are growing in popularity. The present study seeks to determine whether there are any long-term differences between the two designs. Material and methods: A retrospective study of 38 CCS versus 40 FCTS was carried out. Demographic data, clinical variables and radiographic parameters were recorded. Results: Demographic data were comparable. A greater proportion of septic revisions, periprosthetic fractures and previous osteosynthesis failures was observed with FCTS versus CCS (p = 0.012). A greater use of FCTS was recorded in cases with bone defects of type IIIA and higher (p = 0.025). There were no significant differences in terms of in-hospital complications (p = 0.815), postoperative surgical complications or need for reoperation (p = 0.156). The CCS group presented a higher percentage of clinical thigh pain at the end of follow-up (p = 0.006). Additionally, a greater presence of radiolucencies was observed with CCS, especially in proximal zones (1, 7, 10 and 14). More subsidence, tip cortical hypertrophy and stress shielding were recorded in the CCS group. The overall survival at 120 months was 84.2% in the CCS group and 85% in the FCTS group (p = 0.520). When analyzing isolated aseptic loosening as the cause of failure, the survival rate was 94.7% in the CCS group and 95% in the FCTS group (p = 0.506). Conclusions: Both FCTS and CCS with diaphyseal anchorage afford excellent long-term survival rates, with no differences between the two designs. However, a higher incidence of stress shielding, radiolucencies and thigh pain with CCS seems to favor the use of FCTS.Keywords
This publication has 35 references indexed in Scilit:
- Highlights of the 2022 American Joint Replacement Registry Annual ReportArthroplasty Today, 2023
- Micromotion and stress shielding between taper fluted and cylindrical femoral stems for Paprosky bone deficiency type IIIBMUSCULOSKELETAL SURGERY, 2023
- Patterns of Osseointegration and Remodeling in Femoral Revision With Bone Loss Using Modular, Tapered, Fluted, Titanium StemsThe Journal of Arthroplasty, 2011
- Femoral Revision Hip Arthroplasty: A Comparison of Two Stem DesignsClinical Orthopaedics and Related Research, 2010
- Impaction bone grafting in revision hip surgery: past, present and futureCell and Tissue Banking, 2010
- Radiographic Bone Regeneration and Clinical Outcome With the Wagner SL Revision StemThe Journal of Arthroplasty, 2007
- Proximal bone remodelling differed between two types of titanium long femoral components after cementless revision arthroplastyInternational Orthopaedics, 2007
- The Wagner revision prosthesis consistently restores femoral bone structureInternational Orthopaedics, 2000
- Three- to 7-year results with the uncemented SL femoral revision prosthesisArchives of orthopaedic and trauma surgery, 1997
- The Wagner revision stem in alloarthroplasty of the hipArchives of orthopaedic and trauma surgery, 1996