Pablo Sanz-Ruiz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Pablo Sanz-Ruiz has a total of 202 co-authors. Here are the top co-authors by number of shared publications:
Javier Vaquero-Martín
Orthopaedic Surgery and Traumatology Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain
15 shared publications- Javier Vaquero
Department of Orthopaedic Surgery and Traumatology, Hospital General Universitario Gregorio Marañón, 28007 Madrid, Spain
13 shared publications Javier Vaquero
Department of Orthopaedic Surgery and Traumatology General University Hospital Gregorio Marañón Madrid Spain
7 shared publications- Manuel Villanueva-Martínez
Department of Traumatology and Orthopedic Surgery, Avanfi Institute, 28015 Madrid, Spain
7 shared publications - Irene Isabel López-Torres
Department of Orthopaedic Surgery and Traumatology. Hospital Universitario Fundación Jiménez Díaz, IIS-Fundación Jiménez Díaz, Universidad Autónoma de Madrid, Av. De los Reyes Católicos, 2, 28040 Madrid. Spain
6 shared publications - María Guembe
Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain; Department of Clinical Microbiology and Infectious Diseases, Hospital General Universitario Gregorio Marañón, Madrid, Spain
6 shared publications
Latest Publications
- Open Access
- 28 October 2026
- Published by Wiley in International Wound Journal
- Vol. 23 (11) , e71089
Combined Use of Adhesive Mesh Closure and Closed‐Incision Negative Pressure Therapy for High‐Risk Surgical Wounds: A Proof‐Of‐Concept Study
Surgical wound complications remain a major challenge, particularly in high‐risk patients. Closed‐incision negative pressure wound therapy (ciNPWT) and adhesive mesh closure systems have shown benefits independently, but their combined use has not been previously evaluated. This single‐centre prospective proof‐of‐concept study included consecutive patients at extremely high risk of wound complications undergoing complex surgical procedures. All patients were treated with adhesive mesh closure (Dermabond Prineo) and ciNPWT (PICO) using a standardized protocol. Outcomes were compared with a historical cohort treated with conventional skin closure. Primary outcomes were wound healing and surgical site complications; secondary outcomes included persistent drainage, delayed healing, readmissions and duration of therapy. Seventeen surgical procedures (16 patients) were included in the prospective cohort and 39 in the historical cohort. The combined strategy achieved consistent wound healing without device‐related or allergic complications. Compared with controls, no significant difference was observed for the composite outcome of surgical site complications (17.6% vs. 23.1%), although lower rates were observed for persistent drainage (0 vs. 23.1%, p = 0.045), delayed healing (5.9% vs. 20.5%) and readmissions (0 vs. 20.5%); only persistent drainage reached statistical significance. ciNPWT duration was shorter (12.3 vs. 17.3 days; p = 0.006). This combined approach appears feasible and safe in a highly selected cohort of high‐risk patients, with preliminary findings suggesting potential reductions in wound‐related complications.
- 28 October 2026
- Published by Wiley in International Wound Journal
- Vol. 23 (11) , e71089
Open AccessCombined Use of Adhesive Mesh Closure and Closed‐Incision Negative Pressure Therapy for High‐Risk Surgical Wounds: A Proof‐Of‐Concept Study
Surgical wound complications remain a major challenge, particularly in high‐risk patients. Closed‐incision negative pressure wound therapy (ciNPWT) and adhesive mesh closure systems have shown benefits independently, but their combined use has not been previously evaluated. This single‐centre prospective proof‐of‐concept study included consecutive patients at extremely high risk of wound complications undergoing complex surgical procedures. All patients were treated with adhesive mesh closure (Dermabond Prineo) and ciNPWT (PICO) using a standardized protocol. Outcomes were compared with a historical cohort treated with conventional skin closure. Primary outcomes were wound healing and surgical site complications; secondary outcomes included persistent drainage, delayed healing, readmissions and duration of therapy. Seventeen surgical procedures (16 patients) were included in the prospective cohort and 39 in the historical cohort. The combined strategy achieved consistent wound healing without device‐related or allergic complications. Compared with controls, no significant difference was observed for the composite outcome of surgical site complications (17.6% vs. 23.1%), although lower rates were observed for persistent drainage (0 vs. 23.1%, p = 0.045), delayed healing (5.9% vs. 20.5%) and readmissions (0 vs. 20.5%); only persistent drainage reached statistical significance. ciNPWT duration was shorter (12.3 vs. 17.3 days; p = 0.006). This combined approach appears feasible and safe in a highly selected cohort of high‐risk patients, with preliminary findings suggesting potential reductions in wound‐related complications.
- Open Access
- 12 September 2026
- Published by Wiley in Global Challenges
- Vol. 10 (9)
Supercritical Solution Impregnation: A Strategy to Prevent Prosthetic Infections
One of the most devastating and frustrating complications in orthopaedic surgery is infection. A project is underway in our laboratory to explore the use of supercritical CO 2 (scCO 2 ) as an impregnation medium for treating orthopaedic prostheses to prevent infections. We present our results on the incorporation of antibiotics into the polymeric part of prostheses (inserts) using scCO 2 as a green solvent capable of penetrating the inserts carrying the drug without altering their structural integrity. Experiments were performed using pieces of actual knee joint liners of cross‐linked ultra‐high molecular weight polyethylene (UHMWPE) cut into small pieces. Materials were impregnated with the antibiotic clindamycin dissolved in CO 2 at 35–55°C and 100–200 bar. Moderate loadings (0.13%–1.85% mass) were obtained due to the compact nature of the UHMWPE liners and the weak interaction between the drug and the support. Drug loading increased with the CO 2 density and the depressurization rate. The impregnated prosthesis pieces were free of solvent residues and exhibited antibacterial activity against S. epidermidis , evidenced by the formation of inhibition halos, confirming the effectiveness of this approach in preventing bacterial colonization.
- 12 September 2026
- Published by Wiley in Global Challenges
- Vol. 10 (9)
Open AccessSupercritical Solution Impregnation: A Strategy to Prevent Prosthetic Infections
One of the most devastating and frustrating complications in orthopaedic surgery is infection. A project is underway in our laboratory to explore the use of supercritical CO 2 (scCO 2 ) as an impregnation medium for treating orthopaedic prostheses to prevent infections. We present our results on the incorporation of antibiotics into the polymeric part of prostheses (inserts) using scCO 2 as a green solvent capable of penetrating the inserts carrying the drug without altering their structural integrity. Experiments were performed using pieces of actual knee joint liners of cross‐linked ultra‐high molecular weight polyethylene (UHMWPE) cut into small pieces. Materials were impregnated with the antibiotic clindamycin dissolved in CO 2 at 35–55°C and 100–200 bar. Moderate loadings (0.13%–1.85% mass) were obtained due to the compact nature of the UHMWPE liners and the weak interaction between the drug and the support. Drug loading increased with the CO 2 density and the depressurization rate. The impregnated prosthesis pieces were free of solvent residues and exhibited antibacterial activity against S. epidermidis , evidenced by the formation of inhibition halos, confirming the effectiveness of this approach in preventing bacterial colonization.
- Open Access
- 27 March 2026
- Published by MDPI AG in Microorganisms
- Vol. 14 (4) , 768
Clinical Efficacy and Safety of Multiple High-Dose Antibiotic-Loaded Cement Spacers in the Two-Stage Revision of Gram-Positive Periprosthetic Joint Infection
Periprosthetic joint infection (PJI) is a devastating complication after total joint arthroplasty, typically managed through a two-stage revision protocol involving antibiotic-loaded spacers. This study aimed to evaluate the clinical outcomes and safety of a new multiple high-dose antibiotic-loaded cement (MHDALC) spacer against alternative classical antibiotic combinations for Gram-positive PJI. In this retrospective observational study of 102 patients (30 MHDALC vs. 72 control), the MHDALC cohort received spacers prepared with commercial cement (1 g clindamycin and 1 g gentamicin per 40 g) supplemented with manual additions of 4 g vancomycin and 2 g ceftazidime per 40 g of cement, while the control group received the same commercial cement supplemented with 4 g of vancomycin alone. Treatment failure was significantly lower in the MHDALC group (6.6%) compared to the control group (20.8%; p = 0.005). Furthermore, the time to second-stage reimplantation was drastically reduced in the MHDALC cohort (9.1 vs. 17.8 weeks; p = 0.001). Despite the substantially higher antibiotic load, no significant differences were observed regarding mechanical or surgical complications between the two groups (p = 1.00). In conclusion, the use of MHDALC spacers is an effective and safe strategy for treating Gram-positive PJI, significantly improving eradication rates and accelerating the transition to definitive reconstruction without compromising structural integrity.
- 27 March 2026
- Published by MDPI AG in Microorganisms
- Vol. 14 (4) , 768
Open AccessClinical Efficacy and Safety of Multiple High-Dose Antibiotic-Loaded Cement Spacers in the Two-Stage Revision of Gram-Positive Periprosthetic Joint Infection
Periprosthetic joint infection (PJI) is a devastating complication after total joint arthroplasty, typically managed through a two-stage revision protocol involving antibiotic-loaded spacers. This study aimed to evaluate the clinical outcomes and safety of a new multiple high-dose antibiotic-loaded cement (MHDALC) spacer against alternative classical antibiotic combinations for Gram-positive PJI. In this retrospective observational study of 102 patients (30 MHDALC vs. 72 control), the MHDALC cohort received spacers prepared with commercial cement (1 g clindamycin and 1 g gentamicin per 40 g) supplemented with manual additions of 4 g vancomycin and 2 g ceftazidime per 40 g of cement, while the control group received the same commercial cement supplemented with 4 g of vancomycin alone. Treatment failure was significantly lower in the MHDALC group (6.6%) compared to the control group (20.8%; p = 0.005). Furthermore, the time to second-stage reimplantation was drastically reduced in the MHDALC cohort (9.1 vs. 17.8 weeks; p = 0.001). Despite the substantially higher antibiotic load, no significant differences were observed regarding mechanical or surgical complications between the two groups (p = 1.00). In conclusion, the use of MHDALC spacers is an effective and safe strategy for treating Gram-positive PJI, significantly improving eradication rates and accelerating the transition to definitive reconstruction without compromising structural integrity.
- 30 October 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 41 (1) , S129-S138
2025 ICM: Coated Implants
- 30 October 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 41 (1) , S129-S138
2025 ICM: Coated Implants
- Open Access
Evaluation of Prepacked Bone Cement Mixing Systems in Arthroplasty: Implications for Intraoperative Hygiene and Contamination Risk
In cemented endoprosthetics, closed prepacked mixing systems represent the most advanced generation of cementing technology. (1) Background: The purpose of the present study is to evaluate four approved prepacked systems—Palacos® R+G pro, SmartMix™ Cemvac GHV, Optipac® Refobacin and Cemex® System Genta—with a focus on practical handling and intraoperative hygiene. (2) Method: The systems were evaluated according to established standard test methods for bone cements (ISO 5833), including dough time, setting time, additional mechanical tests and the level of system closure. (3) Results: The results show that all systems are safe to use and meet the general requirements, but there are relevant differences in terms of intraoperative hygiene. The Palacos R+G pro system shows significantly shorter doughing and setting times, which helps to minimize wound exposure during surgery and thus significantly reduces the overall operating time and the risk of bacterial contamination. Two of the systems cannot be classified as completely closed “pre-packaged systems.” In two cases, the system must be temporarily opened before mixing to insert the mixing element, which may result in a temporary but clinically relevant impairment of sterility and a corresponding potential risk of contamination. (4) Conclusion: From a hygienic point of view, systems that remain completely closed throughout the entire preparation process can offer advantages in terms of infection prevention. This was the case for all systems tested. Short handling times, reduced exposure of the surgical site and a shorter overall duration of the procedure could further improve intraoperative safety and reduce the risk of contamination. In terms of intraoperative hygiene, the Palacos R+G pro system achieved the best results compared to the three other systems tested due to its rapid readiness for use and comparatively short setting time (according to ISO 5833). Cemex System Genta performed worst in this respect due to its late doughing time and setting time.
Open AccessEvaluation of Prepacked Bone Cement Mixing Systems in Arthroplasty: Implications for Intraoperative Hygiene and Contamination Risk
In cemented endoprosthetics, closed prepacked mixing systems represent the most advanced generation of cementing technology. (1) Background: The purpose of the present study is to evaluate four approved prepacked systems—Palacos® R+G pro, SmartMix™ Cemvac GHV, Optipac® Refobacin and Cemex® System Genta—with a focus on practical handling and intraoperative hygiene. (2) Method: The systems were evaluated according to established standard test methods for bone cements (ISO 5833), including dough time, setting time, additional mechanical tests and the level of system closure. (3) Results: The results show that all systems are safe to use and meet the general requirements, but there are relevant differences in terms of intraoperative hygiene. The Palacos R+G pro system shows significantly shorter doughing and setting times, which helps to minimize wound exposure during surgery and thus significantly reduces the overall operating time and the risk of bacterial contamination. Two of the systems cannot be classified as completely closed “pre-packaged systems.” In two cases, the system must be temporarily opened before mixing to insert the mixing element, which may result in a temporary but clinically relevant impairment of sterility and a corresponding potential risk of contamination. (4) Conclusion: From a hygienic point of view, systems that remain completely closed throughout the entire preparation process can offer advantages in terms of infection prevention. This was the case for all systems tested. Short handling times, reduced exposure of the surgical site and a shorter overall duration of the procedure could further improve intraoperative safety and reduce the risk of contamination. In terms of intraoperative hygiene, the Palacos R+G pro system achieved the best results compared to the three other systems tested due to its rapid readiness for use and comparatively short setting time (according to ISO 5833). Cemex System Genta performed worst in this respect due to its late doughing time and setting time.
- Open Access
- 1 February 2025
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 10 (2) , 82-94
Consensus document on the management of wound closure in orthopaedic surgery
Wounds in orthopaedic surgery differ from wounds in other surgical fields in various ways. Tissues that are highly affected due to the trauma itself, the presence of an orthopaedic implant and the performance of prosthetic surgery in patients with many comorbidities make these wounds need special consideration. Complications of the surgical wound in orthopaedic surgery are not unusual, being the main cause of medical care and readmission in the first 90 days. There is no consensus on the best way to perform closure in orthopaedic surgery. The national ‘Adequate Wound Management in Orthopaedic Surgery’ survey has shown interindividual variability in wound closure and soft tissue management in orthopaedic surgery at the local level. This consensus document, generated by a group of experts in soft tissue management in orthopaedic surgery, proposes recommendations based on evidence (using the GRADE methodology) to promote best practices in this field. This document considers recommendations for surgical wound closure, dressing management and haemostasis. In addition, some of the 32 questions in the national survey, plus others relevant to the subject, were taken as a starting point for developing the contents.
- 1 February 2025
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 10 (2) , 82-94
Open AccessConsensus document on the management of wound closure in orthopaedic surgery
Wounds in orthopaedic surgery differ from wounds in other surgical fields in various ways. Tissues that are highly affected due to the trauma itself, the presence of an orthopaedic implant and the performance of prosthetic surgery in patients with many comorbidities make these wounds need special consideration. Complications of the surgical wound in orthopaedic surgery are not unusual, being the main cause of medical care and readmission in the first 90 days. There is no consensus on the best way to perform closure in orthopaedic surgery. The national ‘Adequate Wound Management in Orthopaedic Surgery’ survey has shown interindividual variability in wound closure and soft tissue management in orthopaedic surgery at the local level. This consensus document, generated by a group of experts in soft tissue management in orthopaedic surgery, proposes recommendations based on evidence (using the GRADE methodology) to promote best practices in this field. This document considers recommendations for surgical wound closure, dressing management and haemostasis. In addition, some of the 32 questions in the national survey, plus others relevant to the subject, were taken as a starting point for developing the contents.
- Open Access
- 10 June 2024
- Published by MDPI AG in Antibiotics
- Vol. 13 (6) , 538
Do High Doses of Multiple Antibiotics Loaded into Bone Cement Spacers Improve the Success Rate in Staphylococcal Periprosthetic Joint Infection When Rifampicin Cannot Be Employed?
Rifampicin is one of the mainstays in treating staphylococcal prosthetic joint infection (PJI). However, discontinuation due to intolerance, drug interactions, and adverse events is common. Two-stage revision surgery remains the gold standard, with the number of revision arthroplasties steadily increasing. This study aims to evaluate the effectiveness and safety of a novel two-stage revision protocol for staphylococcal prosthetic joint infection (PJI) utilizing bone cement spacers loaded with multiple high doses of antibiotics. Additionally, it seeks to analyze outcomes in patients ineligible for rifampicin treatment. A retrospective review of 43 cases of staphylococcal hip and knee prosthetic joint infections (PJIs) from 2012 to 2020 was conducted. In all instances, a commercial cement containing 1 g of gentamicin and 1 g of clindamycin, augmented with 4 g of vancomycin and 2 g of ceftazidime, was employed to cast a spacer manually after thorough surgical debridement. We report an eradication rate of 82%, with no significant differences observed (p = 0.673) between patients treated with (84%, n = 19) and without rifampicin (79%, n = 24). There were no disparities in positive culture rates (7%), spacer replacement (18%), or survival analysis (p = 0.514) after an average follow-up of 68 months (range 10–147) in the absence of systemic toxicity and surgical complications superimposable to those previously reported. In conclusion, two-stage revision with local high doses of ceftazidime, vancomycin, gentamicin, and clindamycin demonstrates high effectiveness in treating staphylococcal PJIs. Notably, systemic rifampicin does not influence the outcomes. This protocol, with multiple high doses of antibiotics loaded into the bone cement spacer, is presented as a viable and safe alternative for patients unsuitable for rifampicin treatment.
- 10 June 2024
- Published by MDPI AG in Antibiotics
- Vol. 13 (6) , 538
Open AccessDo High Doses of Multiple Antibiotics Loaded into Bone Cement Spacers Improve the Success Rate in Staphylococcal Periprosthetic Joint Infection When Rifampicin Cannot Be Employed?
Rifampicin is one of the mainstays in treating staphylococcal prosthetic joint infection (PJI). However, discontinuation due to intolerance, drug interactions, and adverse events is common. Two-stage revision surgery remains the gold standard, with the number of revision arthroplasties steadily increasing. This study aims to evaluate the effectiveness and safety of a novel two-stage revision protocol for staphylococcal prosthetic joint infection (PJI) utilizing bone cement spacers loaded with multiple high doses of antibiotics. Additionally, it seeks to analyze outcomes in patients ineligible for rifampicin treatment. A retrospective review of 43 cases of staphylococcal hip and knee prosthetic joint infections (PJIs) from 2012 to 2020 was conducted. In all instances, a commercial cement containing 1 g of gentamicin and 1 g of clindamycin, augmented with 4 g of vancomycin and 2 g of ceftazidime, was employed to cast a spacer manually after thorough surgical debridement. We report an eradication rate of 82%, with no significant differences observed (p = 0.673) between patients treated with (84%, n = 19) and without rifampicin (79%, n = 24). There were no disparities in positive culture rates (7%), spacer replacement (18%), or survival analysis (p = 0.514) after an average follow-up of 68 months (range 10–147) in the absence of systemic toxicity and surgical complications superimposable to those previously reported. In conclusion, two-stage revision with local high doses of ceftazidime, vancomycin, gentamicin, and clindamycin demonstrates high effectiveness in treating staphylococcal PJIs. Notably, systemic rifampicin does not influence the outcomes. This protocol, with multiple high doses of antibiotics loaded into the bone cement spacer, is presented as a viable and safe alternative for patients unsuitable for rifampicin treatment.
- Open Access
- 18 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (6) , 1745
Comparison of Cylindrical and Tapered Stem Designs for Femoral Revision Hip Arthroplasty
Background: Cylindrical fully-coated cobalt-chromium stems (CCS) have been widely used in femoral revisions. However, monoblock fluted conical tapered stems (FCTS) are growing in popularity. The present study seeks to determine whether there are any long-term differences between the two designs. Material and methods: A retrospective study of 38 CCS versus 40 FCTS was carried out. Demographic data, clinical variables and radiographic parameters were recorded. Results: Demographic data were comparable. A greater proportion of septic revisions, periprosthetic fractures and previous osteosynthesis failures was observed with FCTS versus CCS (p = 0.012). A greater use of FCTS was recorded in cases with bone defects of type IIIA and higher (p = 0.025). There were no significant differences in terms of in-hospital complications (p = 0.815), postoperative surgical complications or need for reoperation (p = 0.156). The CCS group presented a higher percentage of clinical thigh pain at the end of follow-up (p = 0.006). Additionally, a greater presence of radiolucencies was observed with CCS, especially in proximal zones (1, 7, 10 and 14). More subsidence, tip cortical hypertrophy and stress shielding were recorded in the CCS group. The overall survival at 120 months was 84.2% in the CCS group and 85% in the FCTS group (p = 0.520). When analyzing isolated aseptic loosening as the cause of failure, the survival rate was 94.7% in the CCS group and 95% in the FCTS group (p = 0.506). Conclusions: Both FCTS and CCS with diaphyseal anchorage afford excellent long-term survival rates, with no differences between the two designs. However, a higher incidence of stress shielding, radiolucencies and thigh pain with CCS seems to favor the use of FCTS.
- 18 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (6) , 1745
Open AccessComparison of Cylindrical and Tapered Stem Designs for Femoral Revision Hip Arthroplasty
Background: Cylindrical fully-coated cobalt-chromium stems (CCS) have been widely used in femoral revisions. However, monoblock fluted conical tapered stems (FCTS) are growing in popularity. The present study seeks to determine whether there are any long-term differences between the two designs. Material and methods: A retrospective study of 38 CCS versus 40 FCTS was carried out. Demographic data, clinical variables and radiographic parameters were recorded. Results: Demographic data were comparable. A greater proportion of septic revisions, periprosthetic fractures and previous osteosynthesis failures was observed with FCTS versus CCS (p = 0.012). A greater use of FCTS was recorded in cases with bone defects of type IIIA and higher (p = 0.025). There were no significant differences in terms of in-hospital complications (p = 0.815), postoperative surgical complications or need for reoperation (p = 0.156). The CCS group presented a higher percentage of clinical thigh pain at the end of follow-up (p = 0.006). Additionally, a greater presence of radiolucencies was observed with CCS, especially in proximal zones (1, 7, 10 and 14). More subsidence, tip cortical hypertrophy and stress shielding were recorded in the CCS group. The overall survival at 120 months was 84.2% in the CCS group and 85% in the FCTS group (p = 0.520). When analyzing isolated aseptic loosening as the cause of failure, the survival rate was 94.7% in the CCS group and 95% in the FCTS group (p = 0.506). Conclusions: Both FCTS and CCS with diaphyseal anchorage afford excellent long-term survival rates, with no differences between the two designs. However, a higher incidence of stress shielding, radiolucencies and thigh pain with CCS seems to favor the use of FCTS.
- Open Access
- 20 November 2023
- Published by Elsevier in Revista Española de Cirugía Ortopédica y Traumatología
- Vol. 68 (2) , T97-T107
[Translated article] Wound closure after knee and hip replacement (TKA and THA): Survey results on the clinical practice in Spain
- 20 November 2023
- Published by Elsevier in Revista Española de Cirugía Ortopédica y Traumatología
- Vol. 68 (2) , T97-T107
Open Access[Translated article] Wound closure after knee and hip replacement (TKA and THA): Survey results on the clinical practice in Spain