The Inflammatory Phenotype in Failed Metal-On-Metal Hip Arthroplasty Correlates with Blood Metal Concentrations
Open Access
- 26 May 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (5) , e0155121
Abstract
Hip arthroplasty is the standard treatment of a painful hip destruction. The use of modern metal-on-metal (MOM) bearing surfaces gained popularity in total hip arthroplasties during the last decade. Recently, worrisome failures due to adverse reaction to metal debris (ARMD), including pseudotumor response, have been widely reported. However, the pathogenesis of this reaction remains poorly understood. The aim of the present study was to investigate the ARMD response by flow cytometry approach. Sixteen patients with a failed Articular Surface Replacement (ASR) hip prosthesis were included in the study. Samples of pseudotumor tissues collected during revision surgery were degraded by enzyme digestion and cells were typed by flow cytometry. Whole blood chromium and cobalt concentrations were analyzed with mass spectrometry before revision surgery. Flow cytometry analysis showed that the peri-implant pseudotumor tissue expressed two principal phenotypes, namely macrophage-dominated and T-lymphocyte-dominated response; the average portions being 54% (macrophages) and 25% (T-lymphocytes) in macrophage-dominated inflammation and 20% (macrophages) and 54% (T-lymphocytes) in T-lymphocyte-dominated response. The percentages of B-lymphocytes and granulocytes were lower in both phenotypes. Interestingly, the levels of blood chromium and cobalt were significantly higher in patients with macrophage-dominated response. The results suggest that the adverse tissue reactions induced by MOM wear particles contain heterogeneous pathogeneses and that the metal levels are an important factor in the determination of the inflammatory phenotype. The present results support the hypothesis that higher metal levels cause cytotoxicity and tissue injury and macrophages are recruited to clear the necrotic debris. On the other hand, the adverse response developed in association with lower metal levels is T-lymphocyte-dominated and is likely to reflect hypersensitivity reaction.Keywords
Funding Information
- Competitive Research Funding of Tampere University Hospital, Tampere, Finland
This publication has 44 references indexed in Scilit:
- Cobalt-Alloy Implant Debris Induce HIF-1α Hypoxia Associated Responses: A Mechanism for Metal-Specific Orthopedic Implant FailurePLOS ONE, 2013
- Lymphoid Aggregates That Resemble Tertiary Lymphoid Organs Define a Specific Pathological Subset in Metal-on-Metal Hip ReplacementsPLOS ONE, 2013
- Hip resurfacing arthroplasty: short-term survivorship of 4,401 hips from the Finnish Arthroplasty RegisterActa Orthopaedica, 2012
- Adverse reactions to metal debris: histopathological features of periprosthetic soft tissue reactions seen in association with failed metal on metal hip arthroplastiesJournal of Clinical Pathology, 2012
- Bioengineering reasons for the failure of metal-on-metal hip prosthesesThe Journal of Bone and Joint Surgery. British volume, 2011
- Accelerating failure rate of the ASR total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- Histological Features of Pseudotumor-like Tissues From Metal-on-Metal HipsClinical Orthopaedics and Related Research, 2010
- Increased metal allergy in patients with failed metal‐on‐metal hip arthroplasty and peri‐implant T‐lymphocytic inflammationAllergy, 2009
- Orthopaedic metals and their potential toxicity in the arthroplasty patientThe Journal of Bone and Joint Surgery. British volume, 2007
- Free radicals, metals and antioxidants in oxidative stress-induced cancerChemico-Biological Interactions, 2006