MRI does not detect acetabular osteolysis around metal-on-metal Birmingham THA
Open Access
- 18 May 2014
- journal article
- case report
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 134 (7) , 1009-1015
Abstract
Objective Osteolysis has not been recognized as a common failure mode of the Birmingham modular metal-on-metal (MoM) total hip arthroplasty (THA). The clinical value of metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) to assess the periprosthetic soft tissue is well documented; however, the appropriate image modalities to detect periacetabular osteolysis remain unclear. Case summary Eleven patients with periacetabular osteolysis within 3–6 years after uncemented Birmingham modular MoM THA with a synergy stem are presented. All 11 patients received corresponding standardized AP pelvis radiographs, high-quality MARS MRIs and CT scans with a metal artifact reduction sequence. While periacetabular osteolysis around MoM THA was not detected on MARS MRI in ten patients, CT imaging identified osteolysis in all patients. Periacetabular osteolysis appears to be a failure mechanism of the Smith & Nephew Birmingham MoM THA. Discussion There is no evidence in the literature to support the effectiveness of MARS MRI to detect periacetabular osteolysis around cobalt chromium alloy metal-on-metal total hip arthroplasties. Osteolysis due to corrosion-related particles seems to be one of the primary modes of failure in modular MoM THA. Conclusions MRI is not a sensitive test to identify periacetabular osteolysis. The authors recommend CT for the screening of implants with this failure mode. Our study suggests that patients with a Birmingham modular MoM THA are at increased risk to develop acetabular osteolysis and should be carefully monitored for this failure mode.Keywords
This publication has 32 references indexed in Scilit:
- Is Increased Modularity Associated With Increased Fretting and Corrosion Damage in Metal-On-Metal Total Hip Arthroplasty Devices?The Journal of Arthroplasty, 2013
- Radiographically Undetectable Periprosthetic Osteolysis With ASR ImplantsThe Journal of Arthroplasty, 2013
- Revision of metal-on-metal hip arthroplasty in a tertiary centerActa Orthopaedica, 2013
- The ten-year survival of the Birmingham hip resurfacingThe Journal of Bone and Joint Surgery. British volume, 2012
- Accelerating failure rate of the ASR total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- Indications and results of hip resurfacingInternational Orthopaedics, 2010
- Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant materialBMC Musculoskeletal Disorders, 2010
- Wear mechanisms in metal-on-metal bearings: The importance of tribochemical reaction layersJournal of Orthopaedic Research, 2009
- Comparison of CT, MRI, and Radiographs in Assessing Pelvic OsteolysisClinical Orthopaedics and Related Research, 2005