Evaluation of an Automated Priming Bolus for Improving Prandial Glucose Control in Full Closed Loop Delivery
- 3 February 2025
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (2) , 93-100
Abstract
Background: Automated insulin delivery (AID) is widely available to people with type 1 diabetes (T1D), providing superior glycemic control versus traditional methods. The next generation of AID devices focus on minimizing user/device interactions, especially around meals (“full closed loop,” [FCL]). Our goal was to assess the postprandial glycemic impact of the bolus priming system (BPS), an algorithm delivering fixed insulin doses based on the likelihood of a meal having occurred, in conjunction with UVA’s latest AID. Method: Eleven adults with T1D participated in a supervised randomized-crossover trial assessing glycemic control during two 24-h sessions with identical meals and activity—with and without BPS. On the day in-between study sessions, participants underwent food and activity challenges to test BPS safety and robustness. Continuous glucose monitor (CGM) outcomes and total insulin doses were assessed overall and following meals with potential for BPS to dose additional insulin (CGM >90 mg/dL for 1 h prior). Results: Daytime CGM outcomes were similar with and without BPS: time-in-range (TIR) 70–180 mg/dL 70.6% [62.2–76.5] versus 65.7% [58.6%–80.6%]; time-below-range P = 0.047), but CGM outcomes were inconclusive: 4-h-TIR 51.2% [19.8–83.3] versus 40.2% [20.8–56.3] ( P = 0.24). There were no severe adverse events. Conclusion: While there was no difference in TIR, when BPS was active an improved postprandial AUC in FCL was obtained via earlier insulin injection.Keywords
This publication has 20 references indexed in Scilit:
- Trial of Hybrid Closed-Loop Control in Young Children with Type 1 DiabetesNew England Journal of Medicine, 2023
- Multicenter, Randomized Trial of a Bionic Pancreas in Type 1 DiabetesNew England Journal of Medicine, 2022
- Cambridge hybrid closed-loop algorithm in children and adolescents with type 1 diabetes: a multicentre 6-month randomised controlled trialThe Lancet Digital Health, 2022
- Randomized Trial of Closed-Loop Control in Very Young Children with Type 1 DiabetesNew England Journal of Medicine, 2022
- A fully artificial pancreas versus a hybrid artificial pancreas for type 1 diabetes: a single-centre, open-label, randomised controlled, crossover, non-inferiority trialThe Lancet Digital Health, 2021
- Advanced hybrid artificial pancreas system improves on unannounced meal response - In silico comparison to currently available systemComputer Methods and Programs in Biomedicine, 2021
- A Randomized Trial of Closed-Loop Control in Children with Type 1 DiabetesNew England Journal of Medicine, 2020
- Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 DiabetesNew England Journal of Medicine, 2019
- Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in free-living adults with well controlled type 1 diabetes: an open-label, randomised, crossover studyThe Lancet Diabetes & Endocrinology, 2017
- Frequency of Missed Insulin Boluses in Type 1 Diabetes and Its Impact on Diabetes ControlDiabetes Technology & Therapeutics, 2016