Marcela Moscoso-Vasquez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marcela Moscoso-Vasquez has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Ricardo Salvador Sánchez-Peña
Depto. de Investigación y Doctorado, Instituto Tecnológico de Buenos Aires (ITBA), Buenos Aires, Argentina; 2. Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Buenos Aires, Argentina
5 shared publications Patricio Colmegna
Center for Diabetes Technology, University of Virginia, Charlottesville, Virginia, USA
4 shared publications- Marc D. Breton
Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
3 shared publications Sue A. Brown
Center for Diabetes Technology, University of Virginia 1 , Charlottesville, VA
3 shared publicationsChaitanya L.K. Koravi
Center for Diabetes Technology, University of Virginia 1 , Charlottesville, VA
2 shared publicationsDavid Fulkerson
Center for Diabetes Technology, University of Virginia 1 , Charlottesville, VA
2 shared publications
Latest Publications
- 16 December 2025
- Published by American Diabetes Association in Diabetes Care
- Vol. 49 (3) , 401-409
Safety and Feasibility of a Fully Automated Insulin Delivery System: FCL@Home, a Multicenter Randomized Clinical Trial in Individuals With Type 1 Diabetes
OBJECTIVE: Automated insulin delivery (AID) requiring manual premeal boluses are the standard of care for people with type 1 diabetes (T1D). We evaluated the safety and feasibility of the Automated Insulin Delivery as an Adaptive NETwork (AIDANET) system used without meal announcements in both supervised and home settings across a diverse population of people with T1D. RESEARCH DESIGN AND METHODS: Adults (age >25 years), young adults (age 18–25 years), and adolescents (age 14–18 years) were enrolled at three sites in the U.S. to compare the AIDANET system used in fully closed-loop (FCL) with usual care (UC) in a randomized crossover study. Participants spent ∼5 days using FCL in a supervised environment followed by ∼7 days of use at home. The prespecified primary outcome was defined as the change in mean sensor glucose (MSG) between the 2nd week of UC and the week of the FCL at-home period. RESULTS: Overall, 34 participants (12 adults, 10 young adults, 12 adolescents; mean age 25.4 ± 12.6 years; 62% female; mean HbA1c 8.0 ± 1.1%; 94% hybrid closed loop users during UC) completed the study. MSG improved from 178 to 164 mg/dL (UC vs. FCL P = 0.0058). The percentages of time in range (70–180 mg/dL), time in tight range (70–140 mg/dL), and time above range (>180 mg/dL and >250 mg/dL) also significantly improved, primarily overnight. The percentage of time <70 and <54 mg/dL were significantly noninferior in FCL compared with UC. CONCLUSIONS: FCL therapy with the AIDANET system can significantly improve average glycemic control while removing the need for mealtime bolusing for a broad population of people with T1D.
- 16 December 2025
- Published by American Diabetes Association in Diabetes Care
- Vol. 49 (3) , 401-409
Safety and Feasibility of a Fully Automated Insulin Delivery System: FCL@Home, a Multicenter Randomized Clinical Trial in Individuals With Type 1 Diabetes
OBJECTIVE: Automated insulin delivery (AID) requiring manual premeal boluses are the standard of care for people with type 1 diabetes (T1D). We evaluated the safety and feasibility of the Automated Insulin Delivery as an Adaptive NETwork (AIDANET) system used without meal announcements in both supervised and home settings across a diverse population of people with T1D. RESEARCH DESIGN AND METHODS: Adults (age >25 years), young adults (age 18–25 years), and adolescents (age 14–18 years) were enrolled at three sites in the U.S. to compare the AIDANET system used in fully closed-loop (FCL) with usual care (UC) in a randomized crossover study. Participants spent ∼5 days using FCL in a supervised environment followed by ∼7 days of use at home. The prespecified primary outcome was defined as the change in mean sensor glucose (MSG) between the 2nd week of UC and the week of the FCL at-home period. RESULTS: Overall, 34 participants (12 adults, 10 young adults, 12 adolescents; mean age 25.4 ± 12.6 years; 62% female; mean HbA1c 8.0 ± 1.1%; 94% hybrid closed loop users during UC) completed the study. MSG improved from 178 to 164 mg/dL (UC vs. FCL P = 0.0058). The percentages of time in range (70–180 mg/dL), time in tight range (70–140 mg/dL), and time above range (>180 mg/dL and >250 mg/dL) also significantly improved, primarily overnight. The percentage of time <70 and <54 mg/dL were significantly noninferior in FCL compared with UC. CONCLUSIONS: FCL therapy with the AIDANET system can significantly improve average glycemic control while removing the need for mealtime bolusing for a broad population of people with T1D.
- 4 November 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (2) , 325-334
Continuous Glucose Monitoring and Maternal and Neonatal Morbidity in Pregnant People With Type 1 Diabetes
Introduction: Prior studies have not identified if continuous glucose monitoring (CGM) metrics at a critical gestational age window can discriminate risk of adverse pregnancy outcomes. We evaluated late second- and third-trimester CGM metrics by gestational age associated with pregnancy outcomes in gravidas with type 1 diabetes (T1DM). Methods: Dexcom G6 CGM data from a retrospective cohort of singleton gestations with T1DM (2018-2022) at an academic medical center were analyzed. Time in, above, and below range 63 to 140 mg/dL (TIR, TAR, TBR), glycemic variability, and mean glucose concentration were computed in two-week CGM intervals from 24 0 to 39 6 weeks days . Adverse pregnancy outcomes were hypertensive disorders of pregnancy (HDP), large-for-gestational age (LGA), and neonatal hypoglycemia. Linear mixed-effects models were fitted on CGM metrics computed from two-week CGM intervals, with gestational age, adverse pregnancy outcomes (i.e. presence/absence of HDP, LGA, and/or neonatal hypoglycemia), and their interaction as fixed effects. Results: In 87 gravidas with preconception median hemoglobin A1c 6.5% (IQR 6.0, 7.1) and maternal body mass index 24.8 kg/m 2 (IQR 21.9, 27.1), 71% had at least one adverse pregnancy outcome. Between weeks 24 0 and 37 6 , gravidas with HDP had higher TAR and mean glucose and lower TIR ( P < .05). Gravidas with LGA had lower TBR between weeks 24 0 and 35 6 . TIR, TAR, and mean glucose evolution differed by HDP status, with greatest divergence between groups at 28 0 to 29 6 weeks’ gestation ( P ≤ .001). Conclusion: CGM metrics in the late second to early third trimester, a period of peak insulin resistance, may help to distinguish risk of HDP and LGA in gravidas with T1DM.
- 4 November 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 20 (2) , 325-334
Continuous Glucose Monitoring and Maternal and Neonatal Morbidity in Pregnant People With Type 1 Diabetes
Introduction: Prior studies have not identified if continuous glucose monitoring (CGM) metrics at a critical gestational age window can discriminate risk of adverse pregnancy outcomes. We evaluated late second- and third-trimester CGM metrics by gestational age associated with pregnancy outcomes in gravidas with type 1 diabetes (T1DM). Methods: Dexcom G6 CGM data from a retrospective cohort of singleton gestations with T1DM (2018-2022) at an academic medical center were analyzed. Time in, above, and below range 63 to 140 mg/dL (TIR, TAR, TBR), glycemic variability, and mean glucose concentration were computed in two-week CGM intervals from 24 0 to 39 6 weeks days . Adverse pregnancy outcomes were hypertensive disorders of pregnancy (HDP), large-for-gestational age (LGA), and neonatal hypoglycemia. Linear mixed-effects models were fitted on CGM metrics computed from two-week CGM intervals, with gestational age, adverse pregnancy outcomes (i.e. presence/absence of HDP, LGA, and/or neonatal hypoglycemia), and their interaction as fixed effects. Results: In 87 gravidas with preconception median hemoglobin A1c 6.5% (IQR 6.0, 7.1) and maternal body mass index 24.8 kg/m 2 (IQR 21.9, 27.1), 71% had at least one adverse pregnancy outcome. Between weeks 24 0 and 37 6 , gravidas with HDP had higher TAR and mean glucose and lower TIR ( P < .05). Gravidas with LGA had lower TBR between weeks 24 0 and 35 6 . TIR, TAR, and mean glucose evolution differed by HDP status, with greatest divergence between groups at 28 0 to 29 6 weeks’ gestation ( P ≤ .001). Conclusion: CGM metrics in the late second to early third trimester, a period of peak insulin resistance, may help to distinguish risk of HDP and LGA in gravidas with T1DM.
- 9 August 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
Miniaturized Neural Networks for Deploying Fully Closed Loop Insulin Delivery Systems: A Pilot Study Featuring Flexible Meal Announcement Options
Background: Automated insulin delivery (AID) has revolutionized glucose management. Next-generation AID systems focus on reducing user input, particularly for mealtime dosing, aiming for fully closed loop (FCL) control. Our goal was to assess the safety and feasibility of the next iteration of FCL control, using a miniature neural network to enable implementation within existing hardware capabilities. Methods: In a randomized crossover trial, six adults with type 1 diabetes completed seven days of usual care and seven days using AIDANET in free-living conditions. AIDANET is designed to enable FCL control, but carbohydrate counting and a novel easy-bolus strategy were enabled for one day each to test the system in hybrid closed loop modalities. Results: The mean glucose during usual care was 168 ± 24.3 mg/dL, compared to 161.3 ± 16.7 mg/dL using the AIDANET system. Time-in-range (TIR) 70 to 180 mg/dL was 63.3% ± 14.9% in usual care compared to 66.4% ± 8.3% using AIDANET, while time-below-range (TBR) 70 mg/dL remained within acceptable margins (0.9 ± 1 vs 1.6 ± 1.8). There were no serious adverse events during the study. The hybrid bolusing options provided safe glycemic control, with carbohydrate counting achieving 57.1% TIR with 0.6% TBR, and Easy Bolus achieving 70.5% TIR with 1.5% TBR. Conclusion: This pilot-feasibility study demonstrates that the AIDANET system provides safe glycemic control. The small sample size (n = 6) limits overall generalizability, and further larger, statistically powered trials to validate these results are warranted.
- 9 August 2025
- Published by SAGE Publications in Journal of Diabetes Science and Technology
Miniaturized Neural Networks for Deploying Fully Closed Loop Insulin Delivery Systems: A Pilot Study Featuring Flexible Meal Announcement Options
Background: Automated insulin delivery (AID) has revolutionized glucose management. Next-generation AID systems focus on reducing user input, particularly for mealtime dosing, aiming for fully closed loop (FCL) control. Our goal was to assess the safety and feasibility of the next iteration of FCL control, using a miniature neural network to enable implementation within existing hardware capabilities. Methods: In a randomized crossover trial, six adults with type 1 diabetes completed seven days of usual care and seven days using AIDANET in free-living conditions. AIDANET is designed to enable FCL control, but carbohydrate counting and a novel easy-bolus strategy were enabled for one day each to test the system in hybrid closed loop modalities. Results: The mean glucose during usual care was 168 ± 24.3 mg/dL, compared to 161.3 ± 16.7 mg/dL using the AIDANET system. Time-in-range (TIR) 70 to 180 mg/dL was 63.3% ± 14.9% in usual care compared to 66.4% ± 8.3% using AIDANET, while time-below-range (TBR) 70 mg/dL remained within acceptable margins (0.9 ± 1 vs 1.6 ± 1.8). There were no serious adverse events during the study. The hybrid bolusing options provided safe glycemic control, with carbohydrate counting achieving 57.1% TIR with 0.6% TBR, and Easy Bolus achieving 70.5% TIR with 1.5% TBR. Conclusion: This pilot-feasibility study demonstrates that the AIDANET system provides safe glycemic control. The small sample size (n = 6) limits overall generalizability, and further larger, statistically powered trials to validate these results are warranted.
- 3 February 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (2) , 93-100
Evaluation of an Automated Priming Bolus for Improving Prandial Glucose Control in Full Closed Loop Delivery
Background: Automated insulin delivery (AID) is widely available to people with type 1 diabetes (T1D), providing superior glycemic control versus traditional methods. The next generation of AID devices focus on minimizing user/device interactions, especially around meals (“full closed loop,” [FCL]). Our goal was to assess the postprandial glycemic impact of the bolus priming system (BPS), an algorithm delivering fixed insulin doses based on the likelihood of a meal having occurred, in conjunction with UVA’s latest AID. Method: Eleven adults with T1D participated in a supervised randomized-crossover trial assessing glycemic control during two 24-h sessions with identical meals and activity—with and without BPS. On the day in-between study sessions, participants underwent food and activity challenges to test BPS safety and robustness. Continuous glucose monitor (CGM) outcomes and total insulin doses were assessed overall and following meals with potential for BPS to dose additional insulin (CGM >90 mg/dL for 1 h prior). Results: Daytime CGM outcomes were similar with and without BPS: time-in-range (TIR) 70–180 mg/dL 70.6% [62.2–76.5] versus 65.7% [58.6%–80.6%]; time-below-range P = 0.047), but CGM outcomes were inconclusive: 4-h-TIR 51.2% [19.8–83.3] versus 40.2% [20.8–56.3] ( P = 0.24). There were no severe adverse events. Conclusion: While there was no difference in TIR, when BPS was active an improved postprandial AUC in FCL was obtained via earlier insulin injection.
- 3 February 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (2) , 93-100
Evaluation of an Automated Priming Bolus for Improving Prandial Glucose Control in Full Closed Loop Delivery
Background: Automated insulin delivery (AID) is widely available to people with type 1 diabetes (T1D), providing superior glycemic control versus traditional methods. The next generation of AID devices focus on minimizing user/device interactions, especially around meals (“full closed loop,” [FCL]). Our goal was to assess the postprandial glycemic impact of the bolus priming system (BPS), an algorithm delivering fixed insulin doses based on the likelihood of a meal having occurred, in conjunction with UVA’s latest AID. Method: Eleven adults with T1D participated in a supervised randomized-crossover trial assessing glycemic control during two 24-h sessions with identical meals and activity—with and without BPS. On the day in-between study sessions, participants underwent food and activity challenges to test BPS safety and robustness. Continuous glucose monitor (CGM) outcomes and total insulin doses were assessed overall and following meals with potential for BPS to dose additional insulin (CGM >90 mg/dL for 1 h prior). Results: Daytime CGM outcomes were similar with and without BPS: time-in-range (TIR) 70–180 mg/dL 70.6% [62.2–76.5] versus 65.7% [58.6%–80.6%]; time-below-range P = 0.047), but CGM outcomes were inconclusive: 4-h-TIR 51.2% [19.8–83.3] versus 40.2% [20.8–56.3] ( P = 0.24). There were no severe adverse events. Conclusion: While there was no difference in TIR, when BPS was active an improved postprandial AUC in FCL was obtained via earlier insulin injection.
- 20 October 2023
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 17 (6) , 1470-1481
Performance Effect of Adjusting Insulin Sensitivity for Model-Based Automated Insulin Delivery Systems
Background: Model predictive control (MPC) has become one of the most popular control strategies for automated insulin delivery (AID) in type 1 diabetes (T1D). These algorithms rely on a prediction model to determine the best insulin dosing every sampling time. Although these algorithms have been shown to be safe and effective for glucose management through clinical trials, managing the ever-fluctuating relationship between insulin delivery and resulting glucose uptake (aka insulin sensitivity, IS) remains a challenge. We aim to evaluate the effect of informing an AID system with IS on the performance of the system. Method: The University of Virginia (UVA) MPC control-based hybrid closed-loop (HCL) and fully closed-loop (FCL) system was used. One-day simulations at varying levels of IS were run with the UVA/Padova T1D Simulator. The AID system was informed with an estimated value of IS obtained through a mixed meal glucose tolerance test. Relevant controller parameters are updated to inform insulin dosing of IS. Performance of the HCL/FCL system with and without information of the changing IS was assessed using a novel performance metric penalizing the time outside the target glucose range. Results: Feedback in AID systems provides a certain degree tolerance to changes in IS. However, IS-informed bolus and basal dosing improve glycemic outcomes, providing increased protection against hyperglycemia and hypoglycemia according to the individual’s physiological state. Conclusions: The proof-of-concept analysis presented here shows the potentially beneficial effects on system performance of informing the AID system with accurate estimates of IS. In particular, when considering reduced IS, the informed controller provides increased protection against hyperglycemia compared with the naïve controller. Similarly, reduced hypoglycemia is obtained for situations with increased IS. Further tailoring of the adaptation schemes proposed in this work is needed to overcome the increased hypoglycemia observed in the more resistant cases and to optimize the performance of the adaptation method.
- 20 October 2023
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 17 (6) , 1470-1481
Performance Effect of Adjusting Insulin Sensitivity for Model-Based Automated Insulin Delivery Systems
Background: Model predictive control (MPC) has become one of the most popular control strategies for automated insulin delivery (AID) in type 1 diabetes (T1D). These algorithms rely on a prediction model to determine the best insulin dosing every sampling time. Although these algorithms have been shown to be safe and effective for glucose management through clinical trials, managing the ever-fluctuating relationship between insulin delivery and resulting glucose uptake (aka insulin sensitivity, IS) remains a challenge. We aim to evaluate the effect of informing an AID system with IS on the performance of the system. Method: The University of Virginia (UVA) MPC control-based hybrid closed-loop (HCL) and fully closed-loop (FCL) system was used. One-day simulations at varying levels of IS were run with the UVA/Padova T1D Simulator. The AID system was informed with an estimated value of IS obtained through a mixed meal glucose tolerance test. Relevant controller parameters are updated to inform insulin dosing of IS. Performance of the HCL/FCL system with and without information of the changing IS was assessed using a novel performance metric penalizing the time outside the target glucose range. Results: Feedback in AID systems provides a certain degree tolerance to changes in IS. However, IS-informed bolus and basal dosing improve glycemic outcomes, providing increased protection against hyperglycemia and hypoglycemia according to the individual’s physiological state. Conclusions: The proof-of-concept analysis presented here shows the potentially beneficial effects on system performance of informing the AID system with accurate estimates of IS. In particular, when considering reduced IS, the informed controller provides increased protection against hyperglycemia compared with the naïve controller. Similarly, reduced hypoglycemia is obtained for situations with increased IS. Further tailoring of the adaptation schemes proposed in this work is needed to overcome the increased hypoglycemia observed in the more resistant cases and to optimize the performance of the adaptation method.
- 1 May 2022
- Published by Elsevier in ISA Transactions
- Vol. 124, 225-235
Non-pharmaceutical intervention to reduce COVID-19 impact in Argentina
- 1 May 2022
- Published by Elsevier in ISA Transactions
- Vol. 124, 225-235
Non-pharmaceutical intervention to reduce COVID-19 impact in Argentina
- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (9) , 2681-2689
Control-Oriented Model With Intra-Patient Variations for an Artificial Pancreas
In this work, a low-order model designed for glucose regulation in T1DM is obtained from the UVA/Padova metabolic simulator. It captures not only the nonlinear behavior of the glucose-insulin system, but also intra-patient variations related to daily insulin sensitivity ( ${S_{I}}$ ) changes. To overcome the large inter-subject variability, the model can also be personalized based on a priori patient information. The structure is amenable for linear parameter varying (LPV) controller design, and represents the dynamics from the subcutaneous insulin input to the subcutaneous glucose output. The efficacy of this model is evaluated in comparison with a previous control-oriented model which in turn is an improvement of previous models. Both models are compared in terms of their open- and closed-loop differences with respect to the UVA/Padova model. The open-loop analysis is computed through the root mean square error (RMSE) between the glucose deviation predicted by the models and the UVA/Padova simulator. In closed-loop, the ν-gap metric is used to measure the distance in terms of closed-loop performance between the two models. The results are promising and some illustrative simulations are presented.- 27 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (9) , 2681-2689
Control-Oriented Model With Intra-Patient Variations for an Artificial Pancreas
In this work, a low-order model designed for glucose regulation in T1DM is obtained from the UVA/Padova metabolic simulator. It captures not only the nonlinear behavior of the glucose-insulin system, but also intra-patient variations related to daily insulin sensitivity ( ${S_{I}}$ ) changes. To overcome the large inter-subject variability, the model can also be personalized based on a priori patient information. The structure is amenable for linear parameter varying (LPV) controller design, and represents the dynamics from the subcutaneous insulin input to the subcutaneous glucose output. The efficacy of this model is evaluated in comparison with a previous control-oriented model which in turn is an improvement of previous models. Both models are compared in terms of their open- and closed-loop differences with respect to the UVA/Padova model. The open-loop analysis is computed through the root mean square error (RMSE) between the glucose deviation predicted by the models and the UVA/Padova simulator. In closed-loop, the ν-gap metric is used to measure the distance in terms of closed-loop performance between the two models. The results are promising and some illustrative simulations are presented.- 28 February 2019
- Published by Elsevier in Journal of Process Control
- Vol. 76, 133-140
Invalidation and low-order model set for artificial pancreas robust control design
- 28 February 2019
- Published by Elsevier in Journal of Process Control
- Vol. 76, 133-140
Invalidation and low-order model set for artificial pancreas robust control design
- 12 July 2018
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (5) , 914-925
Artificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses
Background: Emerging therapies such as closed-loop (CL) glucose control, also known as artificial pancreas (AP) systems, have shown significant improvement in type 1 diabetes mellitus (T1DM) management. However, demanding patient intervention is still required, particularly at meal times. To reduce treatment burden, the automatic regulation of glucose (ARG) algorithm mitigates postprandial glucose excursions without feedforward insulin boluses. This work assesses feasibility of this new strategy in a clinical trial. Methods: A 36-hour pilot study was performed on five T1DM subjects to validate the ARG algorithm. Subjects wore a subcutaneous continuous glucose monitor (CGM) and an insulin pump. Insulin delivery was solely commanded by the ARG algorithm, without premeal insulin boluses. This was the first clinical trial in Latin America to validate an AP controller. Results: For the total 36-hour period, results were as follows: average time of CGM readings in range 70-250 mg/dl: 88.6%, in range 70-180 mg/dl: 74.7%, <70 mg/dl: 5.8%, and <50 mg/dl: 0.8%. Results improved analyzing the final 15-hour period of this trial. In that case, the time spent in range was 70-250 mg/dl: 94.7%, in range 70-180 mg/dl: 82.6%, <70 mg/dl: 4.1%, and <50 mg/dl: 0.2%. During the last night the time spent in range was 70-250 mg/dl: 95%, in range 70-180 mg/dl: 87.7%, <70 mg/dl: 5.0%, and <50 mg/dl: 0.0%. No severe hypoglycemia occurred. No serious adverse events were reported. Conclusions: The ARG algorithm was successfully validated in a pilot clinical trial, encouraging further tests with a larger number of patients and in outpatient settings.
- 12 July 2018
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (5) , 914-925
Artificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses
Background: Emerging therapies such as closed-loop (CL) glucose control, also known as artificial pancreas (AP) systems, have shown significant improvement in type 1 diabetes mellitus (T1DM) management. However, demanding patient intervention is still required, particularly at meal times. To reduce treatment burden, the automatic regulation of glucose (ARG) algorithm mitigates postprandial glucose excursions without feedforward insulin boluses. This work assesses feasibility of this new strategy in a clinical trial. Methods: A 36-hour pilot study was performed on five T1DM subjects to validate the ARG algorithm. Subjects wore a subcutaneous continuous glucose monitor (CGM) and an insulin pump. Insulin delivery was solely commanded by the ARG algorithm, without premeal insulin boluses. This was the first clinical trial in Latin America to validate an AP controller. Results: For the total 36-hour period, results were as follows: average time of CGM readings in range 70-250 mg/dl: 88.6%, in range 70-180 mg/dl: 74.7%, <70 mg/dl: 5.8%, and <50 mg/dl: 0.8%. Results improved analyzing the final 15-hour period of this trial. In that case, the time spent in range was 70-250 mg/dl: 94.7%, in range 70-180 mg/dl: 82.6%, <70 mg/dl: 4.1%, and <50 mg/dl: 0.2%. During the last night the time spent in range was 70-250 mg/dl: 95%, in range 70-180 mg/dl: 87.7%, <70 mg/dl: 5.0%, and <50 mg/dl: 0.0%. No severe hypoglycemia occurred. No serious adverse events were reported. Conclusions: The ARG algorithm was successfully validated in a pilot clinical trial, encouraging further tests with a larger number of patients and in outpatient settings.