Virtual dynamic contrast enhanced breast MRI using 2D U-Net Architectures.
Authors:
- Hannes SchreiterHSHannes Schreiter
- Lorenz A. KapsnerLKLorenz A. Kapsner
- Dominique HadlerDHDominique Hadler
- Sabine OhlmeyerSOSabine Ohlmeyer
- Ramona ErberRERamona Erber
- Frederik B. LaunFLFrederik B. Laun
- Michael UderMUMichael Uder
- Evelyn WenkelEWEvelyn Wenkel
- Sebastian BickelhauptSBSebastian Bickelhaupt
- Andrzej LiebertALAndrzej Liebert
Preprint
Abstract
Breast Magnetic Resonance Imaging (MRI) examinations routinely include contrast-agent based dynamic contrast-enhanced (DCE) acquisitions. Expanding the accessibility and personalization of breast MRI might be supported amongst others by advancing non-contrast-enhanced MRI, such as virtual dynamic contrast-enhanced techniques (vDCE) utilizing neural networks. This IRB-approved retrospective study includes n=540 breast MRI examinations acquired on a single 3T MRI scanner. Two 2D U-Net architectures were trained using non-contrast-enhanced MRI acquisitions including T1w, T2w and multi-b-value diffusion weighted imaging acquisitions as inputs and either a single (SCO-Net) or multiple (MCO-Net) time points of a DCE series as ground truth. The neural networks predicted a vDCE series corresponding to five consecutive DCE time points. Across all time points, no significant differences in structural similarity index (SSIM) could be found between the SCO-Net and MCO-Net, both achieving a mean SSIM of 0.86. For peak-signal-to-noise-ratio and normalized root-mean-square error, significantly better results could be observed for the MCO-Net reaching scores of 24.42dB and 0.087 respectively. Comparison of manual segmentations of findings on DCE and vDCE images reached a DICE score of 0.61 and an intersection over union (IoU) of 0.47 without significant differences between SCO-Net and MCO-Net. These findings suggest a technical feasibility of generating vDCE image series from unenhanced input acquisitions using neural networks. However, the analysis does not allow drawing any conclusion on the clinical assessment of lesion specific curve kinetics, which need to be assessed prior determining on the feasibility of deriving diagnostically meaningful enhancement characteristics in individual lesions.Keywords
This publication has 18 references indexed in Scilit:
- Impact of non-contrast-enhanced imaging input sequences on the generation of virtual contrast-enhanced breast MRI scans using neural networkEuropean Radiology, 2024
- IMPORTANT-Net: Integrated MRI multi-parametric increment fusion generator with attention network for synthesizing absent dataInformation Fusion, 2024
- Optimized, Person-Centered Workflow Design for a High-Throughput Breast MRI Screening Facility—A Simulation StudyInvestigative Radiology, 2024
- Tumor-Attentive Segmentation-Guided GAN for Synthesizing Breast Contrast-Enhanced MRI Without Contrast AgentsIEEE Journal of Translational Engineering in Health and Medicine, 2022
- Anthropogenic gadolinium in freshwater and drinking water systemsWater Research, 2020
- Comparison of Study Activity Times for “Full” versus “Fast MRI” for Breast Cancer ScreeningJournal of the American College of Radiology, 2019
- Gadolinium as a new emerging contaminant of aquatic environmentsEnvironmental Toxicology and Chemistry, 2018
- Measures of Model Performance Based On the Log Accuracy RatioSpace Weather, 2018
- The first step for neuroimaging data analysis: DICOM to NIfTI conversionJournal of Neuroscience Methods, 2016
- 3D Slicer as an image computing platform for the Quantitative Imaging NetworkMagnetic Resonance Imaging, 2012