Sebastian Bickelhaupt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sebastian Bickelhaupt has a total of 187 co-authors. Here are the top co-authors by number of shared publications:
- Michael Uder
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
14 shared publications - Frederik Bernd Laun
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
12 shared publications - Tristan Anselm Kuder
Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Faculty of Physics and Astronomy, Heidelberg University, Im Neuenheimer Feld 226, 69120 Heidelberg, Germany
11 shared publications - Sabine Ohlmeyer
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
9 shared publications Heinz-Peter Schlemmer
8 shared publications- Lorenz A. Kapsner
Medical Informatics, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91058 Erlangen, Germany
8 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by MDPI AG in Tomography
- Vol. 12 (7) , 105
Can AI Detect What Is Not Injected? Evaluation of Lesion Detection in Virtual Contrast-Enhanced Breast MRI Using a Large-Scale AI Model Trained on GBCA-Enhanced Data
Background/Objectives: Artificial intelligence (AI) can support lesion detection in gadolinium-based contrast agent-enhanced (GBCA-enhanced) breast MRI. However, its effectiveness on virtual contrast-enhanced (vCE) images remains unclear. This feasibility study evaluated the publicly available MAMA-MIA nnU-Net model trained on GBCA-enhanced data using an independent cohort of both GBCA-enhanced and vCE breast MRI. Methods: This IRB-approved retrospective study included the publicly available nnU-Net model trained on n = 1506 MAMA-MIA breast MRI scans and a cohort of n = 2126 in-house 3T breast MRI scans. A generative adversarial network (Pix2Pix-GAN) was developed on n = 1870 of the in-house scans and used to generate vCE data on the remaining independent n = 256 in-house cases. The MAMA-MIA nnU-net was applied to both GBCA-enhanced (GBCA) and corresponding vCE images. Ground-truth segmentations of malignant lesions served to calculate the Dice score, Hausdorff distance, and lesion dimension differences. Results: The final test set comprised n = 250 cases (n = 69 malignant, n = 181 benign). Lesion detection rates were 91% (n = 63/n = 69; 95% confidence interval (CI): 82.3–96.0%) for GBCA and 84% (n = 58/n = 69; 95% CI: 73.7–90.9%) for vCE. Two lesions missed in GBCA were identified by vCE. The Hausdorff distances were similar (GBCA: 6.4 (IQR: 3.2–9.3; 95% CI: 5.2–7.8) mm; vCE: 6.7 (IQR: 3.9–9.7; 95% CI: 5.3–8.0) mm, p = 0.564). The Dice scores showed minor differences (GBCA: 0.829 (IQR: 0.723–0.900; 95% CI: 0.786–0.865) vs. vCE: 0.826 (IQR: 0.720–0.857; 95% CI: 0.770–0.836); p < 0.001). vCE images had slightly higher non-target tissue segmentation (median 6072 mm3 vs. 5754 mm3). Conclusions: A GBCA-trained algorithm demonstrated some cross-domain transferability to vCE images, albeit with a reduced case-level sensitivity of 84% (95% CI: 73.7–90.9%) vs. 91% (95% CI: 82.3–96.0%). Based on these preliminary results, further research, including larger cohorts and more diverse datasets, is warranted.
- 16 July 2026
- Published by MDPI AG in Tomography
- Vol. 12 (7) , 105
Open AccessCan AI Detect What Is Not Injected? Evaluation of Lesion Detection in Virtual Contrast-Enhanced Breast MRI Using a Large-Scale AI Model Trained on GBCA-Enhanced Data
Background/Objectives: Artificial intelligence (AI) can support lesion detection in gadolinium-based contrast agent-enhanced (GBCA-enhanced) breast MRI. However, its effectiveness on virtual contrast-enhanced (vCE) images remains unclear. This feasibility study evaluated the publicly available MAMA-MIA nnU-Net model trained on GBCA-enhanced data using an independent cohort of both GBCA-enhanced and vCE breast MRI. Methods: This IRB-approved retrospective study included the publicly available nnU-Net model trained on n = 1506 MAMA-MIA breast MRI scans and a cohort of n = 2126 in-house 3T breast MRI scans. A generative adversarial network (Pix2Pix-GAN) was developed on n = 1870 of the in-house scans and used to generate vCE data on the remaining independent n = 256 in-house cases. The MAMA-MIA nnU-net was applied to both GBCA-enhanced (GBCA) and corresponding vCE images. Ground-truth segmentations of malignant lesions served to calculate the Dice score, Hausdorff distance, and lesion dimension differences. Results: The final test set comprised n = 250 cases (n = 69 malignant, n = 181 benign). Lesion detection rates were 91% (n = 63/n = 69; 95% confidence interval (CI): 82.3–96.0%) for GBCA and 84% (n = 58/n = 69; 95% CI: 73.7–90.9%) for vCE. Two lesions missed in GBCA were identified by vCE. The Hausdorff distances were similar (GBCA: 6.4 (IQR: 3.2–9.3; 95% CI: 5.2–7.8) mm; vCE: 6.7 (IQR: 3.9–9.7; 95% CI: 5.3–8.0) mm, p = 0.564). The Dice scores showed minor differences (GBCA: 0.829 (IQR: 0.723–0.900; 95% CI: 0.786–0.865) vs. vCE: 0.826 (IQR: 0.720–0.857; 95% CI: 0.770–0.836); p < 0.001). vCE images had slightly higher non-target tissue segmentation (median 6072 mm3 vs. 5754 mm3). Conclusions: A GBCA-trained algorithm demonstrated some cross-domain transferability to vCE images, albeit with a reduced case-level sensitivity of 84% (95% CI: 73.7–90.9%) vs. 91% (95% CI: 82.3–96.0%). Based on these preliminary results, further research, including larger cohorts and more diverse datasets, is warranted.
- Open Access
- 12 April 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (8) , 1145
Evaluation of Individual T1w-DIXON Contrasts for Subtraction Generation in Dynamic Contrast-Enhanced Breast MRI
Background/Objectives: To evaluate the influence of different DIXON contrasts on the quality of subtraction images in dynamic breast MRI using maximum intensity projections (MIPs). Methods: This retrospective study included n = 40 women (median age: 53.5 years, range 23–83) undergoing clinically indicated breast MRI (3T). For each MRI examination, two independent readers individually evaluated GBCA-enhanced subtraction MIPS for different timepoints (n = 5) and DIXON contrasts (n = 4) per breast, resulting in a total of 800 individual evaluations. Evaluations comprised (a) qualitative measures, using Likert-scores for artefact strength, breast parenchyma visibility, lesion visibility and reading confidence; and (b) signal intensity, measured in three regions of interest with the apparent signal-to-noise ratio (aSNR) and apparent contrast-to-noise ratio (aCNR) calculated. The evaluation results were analysed to identify differences between DIXON contrasts. Results: The “only water” DIXON contrast at ~120s after GBCA injection achieved the highest lesion conspicuity and reading confidence scores and lowest artefact scores; however, its performance was not statistically significant (p > 0.05) compared to the “in-phase” and “opposed-phase” subtractions. The aCNR at the second timepoint was slightly, but not significantly (p > 0.05), lower than the first timepoint, whilst aSNR increased significantly from the first to second timepoint in all contrasts. Conclusions: Subtraction MIPs derived from the “only water” DIXON contrast achieved the highest qualitative scoring for lesion conspicuity and confidence, with the aSNR increasing and aCNR decreasing between the first and second timepoints.
- 12 April 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (8) , 1145
Open AccessEvaluation of Individual T1w-DIXON Contrasts for Subtraction Generation in Dynamic Contrast-Enhanced Breast MRI
Background/Objectives: To evaluate the influence of different DIXON contrasts on the quality of subtraction images in dynamic breast MRI using maximum intensity projections (MIPs). Methods: This retrospective study included n = 40 women (median age: 53.5 years, range 23–83) undergoing clinically indicated breast MRI (3T). For each MRI examination, two independent readers individually evaluated GBCA-enhanced subtraction MIPS for different timepoints (n = 5) and DIXON contrasts (n = 4) per breast, resulting in a total of 800 individual evaluations. Evaluations comprised (a) qualitative measures, using Likert-scores for artefact strength, breast parenchyma visibility, lesion visibility and reading confidence; and (b) signal intensity, measured in three regions of interest with the apparent signal-to-noise ratio (aSNR) and apparent contrast-to-noise ratio (aCNR) calculated. The evaluation results were analysed to identify differences between DIXON contrasts. Results: The “only water” DIXON contrast at ~120s after GBCA injection achieved the highest lesion conspicuity and reading confidence scores and lowest artefact scores; however, its performance was not statistically significant (p > 0.05) compared to the “in-phase” and “opposed-phase” subtractions. The aCNR at the second timepoint was slightly, but not significantly (p > 0.05), lower than the first timepoint, whilst aSNR increased significantly from the first to second timepoint in all contrasts. Conclusions: Subtraction MIPs derived from the “only water” DIXON contrast achieved the highest qualitative scoring for lesion conspicuity and confidence, with the aSNR increasing and aCNR decreasing between the first and second timepoints.
- Open Access
- 16 January 2026
- Published by MDPI AG in Tomography
- Vol. 12 (1) , 11
Overestimation of the Apparent Diffusion Coefficient in Diffusion-Weighted Imaging Due to Residual Fat Signal and Out-of-Phase Conditions
Background/Objectives: Diffusion-weighted imaging (DWI) is a magnetic resonance technique used to map the apparent diffusion coefficient () of water in human tissue. assessment plays a central role in clinical diagnostics, as malignant tissues typically exhibit reduced water mobility and, thus, lower values. Accurately measuring the requires effective fat suppression to prevent contamination from the residual fat signal, which is commonly believed to cause underestimation. This study aimed to demonstrate that overestimation may occur as well. Methods: Our theoretical analysis shows that out-of-phase conditions between fat and water signals lead to overestimations. We performed demonstration experiments on fat–water phantoms and the breasts of 10 healthy female volunteers. In particular, we considered three out-of-phase conditions: First and second, short-time inversion recovery (STIR) fat suppression with incorrect inversion time and incorrect flip angle, respectively. Third, phase differences due to spectral fat saturation. The values were assessed in regions of interest (ROIs) that included both water and residual fat signals. Results: In the phantoms and the volunteer data, ROIs containing both fat and water signals consistently exhibited lower values under in-phase conditions and higher values under out-of-phase conditions. Conclusions: We demonstrated that out-of-phase conditions can result in overestimation in the presence of residual fat signals, potentially resulting in false-negative classifications where malignant lesions are misinterpreted as benign due to an elevated . Out-of-phase fat and water signals might also reduce lesion conspicuity in high b-value images, potentially masking clinically relevant findings.- 16 January 2026
- Published by MDPI AG in Tomography
- Vol. 12 (1) , 11
Open AccessOverestimation of the Apparent Diffusion Coefficient in Diffusion-Weighted Imaging Due to Residual Fat Signal and Out-of-Phase Conditions
Background/Objectives: Diffusion-weighted imaging (DWI) is a magnetic resonance technique used to map the apparent diffusion coefficient () of water in human tissue. assessment plays a central role in clinical diagnostics, as malignant tissues typically exhibit reduced water mobility and, thus, lower values. Accurately measuring the requires effective fat suppression to prevent contamination from the residual fat signal, which is commonly believed to cause underestimation. This study aimed to demonstrate that overestimation may occur as well. Methods: Our theoretical analysis shows that out-of-phase conditions between fat and water signals lead to overestimations. We performed demonstration experiments on fat–water phantoms and the breasts of 10 healthy female volunteers. In particular, we considered three out-of-phase conditions: First and second, short-time inversion recovery (STIR) fat suppression with incorrect inversion time and incorrect flip angle, respectively. Third, phase differences due to spectral fat saturation. The values were assessed in regions of interest (ROIs) that included both water and residual fat signals. Results: In the phantoms and the volunteer data, ROIs containing both fat and water signals consistently exhibited lower values under in-phase conditions and higher values under out-of-phase conditions. Conclusions: We demonstrated that out-of-phase conditions can result in overestimation in the presence of residual fat signals, potentially resulting in false-negative classifications where malignant lesions are misinterpreted as benign due to an elevated . Out-of-phase fat and water signals might also reduce lesion conspicuity in high b-value images, potentially masking clinically relevant findings. - 23 September 2025
- Published by Oxford University Press (OUP) in Journal of the American Medical Informatics Association
- Vol. 32 (12) , 1908-1915
Including AI in diffusion-weighted breast MRI has potential to increase reader confidence and reduce workload
Objectives: Breast diffusion-weighted imaging (DWI) has shown potential as a standalone imaging technique for certain indications, eg, supplemental screening of women with dense breasts. This study evaluates an artificial intelligence (AI)-powered computer-aided diagnosis (CAD) system for clinical interpretation and workload reduction in breast DWI. Materials and Methods: This retrospective IRB-approved study included: n = 824 examinations for model development (2017-2020) and n = 235 for evaluation (01/2021-06/2021). Readings were performed by three readers using either the AI-CAD or manual readings. BI-RADS-like (Breast Imaging Reporting and Data System) classification was based on DWI. Histopathology served as ground truth. The model was nnDetection-based, trained using 5-fold cross-validation and ensembling. Statistical significance was determined using McNemar’s test. Inter-rater agreement was calculated using Cohen’s kappa. Model performance was calculated using the area under the receiver operating curve (AUC). Results: The AI-augmented approach significantly reduced BI-RADS-like 3 calls in breast DWI by 29% (P =.019) and increased interrater agreement (0.57 ± 0.10 vs 0.49 ± 0.11), while preserving diagnostic accuracy. Two of the three readers detected more malignant lesions (63/69 vs 59/69 and 64/69 vs 62/69) with the AI-CAD. The AI model achieved an AUC of 0.78 (95% CI: [0.72, 0.85]; P <.001), which increased for women at screening age to 0.82 (95% CI: [0.73, 0.90]; P <.001), indicating a potential for workload reduction of 20.9% at 96% sensitivity. Discussion and Conclusion: Breast DWI might benefit from AI support. In our study, AI showed potential for reduction of BI-RADS-like 3 calls and increase of inter-rater agreement. However, given the limited study size, further research is needed.
- 23 September 2025
- Published by Oxford University Press (OUP) in Journal of the American Medical Informatics Association
- Vol. 32 (12) , 1908-1915
Including AI in diffusion-weighted breast MRI has potential to increase reader confidence and reduce workload
Objectives: Breast diffusion-weighted imaging (DWI) has shown potential as a standalone imaging technique for certain indications, eg, supplemental screening of women with dense breasts. This study evaluates an artificial intelligence (AI)-powered computer-aided diagnosis (CAD) system for clinical interpretation and workload reduction in breast DWI. Materials and Methods: This retrospective IRB-approved study included: n = 824 examinations for model development (2017-2020) and n = 235 for evaluation (01/2021-06/2021). Readings were performed by three readers using either the AI-CAD or manual readings. BI-RADS-like (Breast Imaging Reporting and Data System) classification was based on DWI. Histopathology served as ground truth. The model was nnDetection-based, trained using 5-fold cross-validation and ensembling. Statistical significance was determined using McNemar’s test. Inter-rater agreement was calculated using Cohen’s kappa. Model performance was calculated using the area under the receiver operating curve (AUC). Results: The AI-augmented approach significantly reduced BI-RADS-like 3 calls in breast DWI by 29% (P =.019) and increased interrater agreement (0.57 ± 0.10 vs 0.49 ± 0.11), while preserving diagnostic accuracy. Two of the three readers detected more malignant lesions (63/69 vs 59/69 and 64/69 vs 62/69) with the AI-CAD. The AI model achieved an AUC of 0.78 (95% CI: [0.72, 0.85]; P <.001), which increased for women at screening age to 0.82 (95% CI: [0.73, 0.90]; P <.001), indicating a potential for workload reduction of 20.9% at 96% sensitivity. Discussion and Conclusion: Breast DWI might benefit from AI support. In our study, AI showed potential for reduction of BI-RADS-like 3 calls and increase of inter-rater agreement. However, given the limited study size, further research is needed.
- Open Access
- 23 September 2025
- Published by MDPI AG in Tomography
- Vol. 11 (10) , 106
Flow-Compensated vs. Monopolar Diffusion Encodings: Differences in Lesion Detectability Regarding Size and Position in Liver Diffusion-Weighted MRI
Background/Objectives: Diffusion-weighted imaging (DWI) of the liver is prone to cardiac motion-induced signal dropout, which can be reduced using flow-compensated (FloCo) instead of monopolar (MP) diffusion encodings. This study examined differences in lesion detection capabilities between FloCo and MP DWI and whether visibility depends on lesion size and position. Methods: Forty patients with at least one known or suspected focal liver lesion (FLL) underwent FloCo and MP DWI. For both sequences, b = 800 s/mm2 images were used to manually segment FLLs, which were then sorted by size and location (liver segment). The number of detected lesions, the sensitivity, and the contrast-to-noise ratio (CNR) were calculated and compared across sequences, sizes, and locations. Results: Significantly more lesions were detected using FloCo DWI compared to MP DWI (1211 vs. 1154; p < 0.001). In total, 1258 unique lesions were detected, 104 of which were identified only by FloCo DWI, and 47 of which only by MP DWI. The sensitivities of FloCo DWI and MP DWI were 96.3% (95% CI: 95.1–97.2%) and 91.7% (95% CI: 90.1–93.2%), respectively. The largest additional lesion found with only one of the two sequences measured 10.9 mm in FloCo DWI and 8.2 mm in MP DWI. In relative numbers, more additional FloCo lesions were found in the left liver lobe than in the right liver lobe (6.4% vs. 3.5%). The lesion CNR was significantly higher for FloCo DWI than for MP DWI (p < 0.05) for all evaluated size intervals and liver segments. Conclusions: FloCo DWI appears to enhance the detectability of FLLs compared to MP DWI, particularly for small liver lesions and lesions in the left liver lobe.
- 23 September 2025
- Published by MDPI AG in Tomography
- Vol. 11 (10) , 106
Open AccessFlow-Compensated vs. Monopolar Diffusion Encodings: Differences in Lesion Detectability Regarding Size and Position in Liver Diffusion-Weighted MRI
Background/Objectives: Diffusion-weighted imaging (DWI) of the liver is prone to cardiac motion-induced signal dropout, which can be reduced using flow-compensated (FloCo) instead of monopolar (MP) diffusion encodings. This study examined differences in lesion detection capabilities between FloCo and MP DWI and whether visibility depends on lesion size and position. Methods: Forty patients with at least one known or suspected focal liver lesion (FLL) underwent FloCo and MP DWI. For both sequences, b = 800 s/mm2 images were used to manually segment FLLs, which were then sorted by size and location (liver segment). The number of detected lesions, the sensitivity, and the contrast-to-noise ratio (CNR) were calculated and compared across sequences, sizes, and locations. Results: Significantly more lesions were detected using FloCo DWI compared to MP DWI (1211 vs. 1154; p < 0.001). In total, 1258 unique lesions were detected, 104 of which were identified only by FloCo DWI, and 47 of which only by MP DWI. The sensitivities of FloCo DWI and MP DWI were 96.3% (95% CI: 95.1–97.2%) and 91.7% (95% CI: 90.1–93.2%), respectively. The largest additional lesion found with only one of the two sequences measured 10.9 mm in FloCo DWI and 8.2 mm in MP DWI. In relative numbers, more additional FloCo lesions were found in the left liver lobe than in the right liver lobe (6.4% vs. 3.5%). The lesion CNR was significantly higher for FloCo DWI than for MP DWI (p < 0.05) for all evaluated size intervals and liver segments. Conclusions: FloCo DWI appears to enhance the detectability of FLLs compared to MP DWI, particularly for small liver lesions and lesions in the left liver lobe.
- Open Access
- 12 June 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-16
AI-Based screening for thoracic aortic aneurysms in routine breast MRI
Prognosis for thoracic aortic aneurysms is significantly worse for women than men, with a higher mortality rate observed among female patients. The increasing use of magnetic resonance breast imaging (MRI) offers a unique opportunity for simultaneous detection of both breast cancer and thoracic aortic aneurysms. We retrospectively validate a fully-automated artificial neural network (ANN) pipeline on 5057 breast MRI examinations from public (Duke University Hospital/EA1141 trial) and in-house (Erlangen University Hospital) data. The ANN, benchmarked against 3D-ground-truth segmentations, clinical reports, and a multireader panel, demonstrates high technical robustness (dice/clDice 0.88-0.91/0.97-0.99) across different vendors and field strengths. The ANN improves aneurysm detection rates by 3.5-fold compared with routine clinical readings, highlighting its potential to improve early diagnosis and patient outcomes. Notably, a higher odds ratio (OR = 2.29, CI: [0.55,9.61]) for thoracic aortic aneurysms is observed in women with breast cancer or breast cancer history, suggesting potential further benefits from integrated simultaneous assessment for cancer and aortic aneurysms.
- 12 June 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-16
Open AccessAI-Based screening for thoracic aortic aneurysms in routine breast MRI
Prognosis for thoracic aortic aneurysms is significantly worse for women than men, with a higher mortality rate observed among female patients. The increasing use of magnetic resonance breast imaging (MRI) offers a unique opportunity for simultaneous detection of both breast cancer and thoracic aortic aneurysms. We retrospectively validate a fully-automated artificial neural network (ANN) pipeline on 5057 breast MRI examinations from public (Duke University Hospital/EA1141 trial) and in-house (Erlangen University Hospital) data. The ANN, benchmarked against 3D-ground-truth segmentations, clinical reports, and a multireader panel, demonstrates high technical robustness (dice/clDice 0.88-0.91/0.97-0.99) across different vendors and field strengths. The ANN improves aneurysm detection rates by 3.5-fold compared with routine clinical readings, highlighting its potential to improve early diagnosis and patient outcomes. Notably, a higher odds ratio (OR = 2.29, CI: [0.55,9.61]) for thoracic aortic aneurysms is observed in women with breast cancer or breast cancer history, suggesting potential further benefits from integrated simultaneous assessment for cancer and aortic aneurysms.
- 25 April 2025
- Published by Wolters Kluwer Health in Investigative Radiology
Feasibility of 7 T 39K/23Na Magnetic Resonance Imaging for assessing muscular ion balance in hypokalemic periodic paralysis
Objectives: Recently introduced potassium-39-(39K)-MRI provides a noninvasive approach to assess typically high intracellular K+-levels and can be combined with sodium-23-(23Na)-MRI. The aim of this study was to evaluate 39K/23Na muscle ion homeostasis in hypokalemic periodic paralysis (HypoPP), a rare muscular ion channelopathy, using 7 T MRI. Materials and Methods: Lower legs of patients with HypoPP and healthy controls were prospectively examined between August 2022 and July 2023 (case-control study). Scanning protocol at 3 T included T1-weighted, T2-weighted STIR sequences, a 6-point-Dixon-type gradient echo and a T2-mapping sequence. 39K/23Na data were acquired at 7 T using acquisition-weighted Stack-of-Stars sequences. Apparent tissue 39K/23Na concentrations (aTPC/aTSC) were calculated after correcting for partial-volume and relaxation effects and corrected for proton-density fat-fractions to account for fatty replacement. A 23Na-inversion-recovery (23Na-IR) sequence served to introduce a stronger intracellular weighting. Differences in central tendency between the HypoPP and control groups and correlations were analyzed. Results: Thirteen HypoPP-participants and 13 controls were included. Extent of fatty replacement/edema-like changes varied highly with the gastrocnemius medialis muscle most affected. The HypoPP group showed significantly increased aTSC in all 7 analyzed muscles and decreased aTPC in 3 specific muscles. Across all muscles, the mean aTSC was higher in the HypoPP group (median: 33.4 vs 22.5 mM, mean ± SD: 34.3 ± 6.8 vs 21.0 ± 4.8 mM, P < 0.001), whereas the mean aTPC was lower (98.7 vs 109.0 mM, 97.9 ± 12.0 vs 108.7 ± 10.4 mM, P = 0.02). The 23Na-IR signal was strongly correlated with aTSC (r = 0.77, P < 0.001). Conclusions: Combined 39K/23Na MRI at 7 T demonstrated alterations of sodium and potassium ion homeostasis in HypoPP. These findings could be helpful for a better pathophysiological understanding of HypoPP and may aid in future studies to assess disease extent or monitor treatment efficacy.
- 25 April 2025
- Published by Wolters Kluwer Health in Investigative Radiology
Feasibility of 7 T 39K/23Na Magnetic Resonance Imaging for assessing muscular ion balance in hypokalemic periodic paralysis
Objectives: Recently introduced potassium-39-(39K)-MRI provides a noninvasive approach to assess typically high intracellular K+-levels and can be combined with sodium-23-(23Na)-MRI. The aim of this study was to evaluate 39K/23Na muscle ion homeostasis in hypokalemic periodic paralysis (HypoPP), a rare muscular ion channelopathy, using 7 T MRI. Materials and Methods: Lower legs of patients with HypoPP and healthy controls were prospectively examined between August 2022 and July 2023 (case-control study). Scanning protocol at 3 T included T1-weighted, T2-weighted STIR sequences, a 6-point-Dixon-type gradient echo and a T2-mapping sequence. 39K/23Na data were acquired at 7 T using acquisition-weighted Stack-of-Stars sequences. Apparent tissue 39K/23Na concentrations (aTPC/aTSC) were calculated after correcting for partial-volume and relaxation effects and corrected for proton-density fat-fractions to account for fatty replacement. A 23Na-inversion-recovery (23Na-IR) sequence served to introduce a stronger intracellular weighting. Differences in central tendency between the HypoPP and control groups and correlations were analyzed. Results: Thirteen HypoPP-participants and 13 controls were included. Extent of fatty replacement/edema-like changes varied highly with the gastrocnemius medialis muscle most affected. The HypoPP group showed significantly increased aTSC in all 7 analyzed muscles and decreased aTPC in 3 specific muscles. Across all muscles, the mean aTSC was higher in the HypoPP group (median: 33.4 vs 22.5 mM, mean ± SD: 34.3 ± 6.8 vs 21.0 ± 4.8 mM, P < 0.001), whereas the mean aTPC was lower (98.7 vs 109.0 mM, 97.9 ± 12.0 vs 108.7 ± 10.4 mM, P = 0.02). The 23Na-IR signal was strongly correlated with aTSC (r = 0.77, P < 0.001). Conclusions: Combined 39K/23Na MRI at 7 T demonstrated alterations of sodium and potassium ion homeostasis in HypoPP. These findings could be helpful for a better pathophysiological understanding of HypoPP and may aid in future studies to assess disease extent or monitor treatment efficacy.
- Open Access
- 16 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 4921-4924
Lesion-mimicking DIXON swap artifact in contrast-enhanced subtraction breast MRI
- 16 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 4921-4924
Open AccessLesion-mimicking DIXON swap artifact in contrast-enhanced subtraction breast MRI
- Open Access
Virtual dynamic contrast enhanced breast MRI using 2D U-Net Architectures.
Breast Magnetic Resonance Imaging (MRI) examinations routinely include contrast-agent based dynamic contrast-enhanced (DCE) acquisitions. Expanding the accessibility and personalization of breast MRI might be supported amongst others by advancing non-contrast-enhanced MRI, such as virtual dynamic contrast-enhanced techniques (vDCE) utilizing neural networks. This IRB-approved retrospective study includes n=540 breast MRI examinations acquired on a single 3T MRI scanner. Two 2D U-Net architectures were trained using non-contrast-enhanced MRI acquisitions including T1w, T2w and multi-b-value diffusion weighted imaging acquisitions as inputs and either a single (SCO-Net) or multiple (MCO-Net) time points of a DCE series as ground truth. The neural networks predicted a vDCE series corresponding to five consecutive DCE time points. Across all time points, no significant differences in structural similarity index (SSIM) could be found between the SCO-Net and MCO-Net, both achieving a mean SSIM of 0.86. For peak-signal-to-noise-ratio and normalized root-mean-square error, significantly better results could be observed for the MCO-Net reaching scores of 24.42dB and 0.087 respectively. Comparison of manual segmentations of findings on DCE and vDCE images reached a DICE score of 0.61 and an intersection over union (IoU) of 0.47 without significant differences between SCO-Net and MCO-Net. These findings suggest a technical feasibility of generating vDCE image series from unenhanced input acquisitions using neural networks. However, the analysis does not allow drawing any conclusion on the clinical assessment of lesion specific curve kinetics, which need to be assessed prior determining on the feasibility of deriving diagnostically meaningful enhancement characteristics in individual lesions.
Open AccessVirtual dynamic contrast enhanced breast MRI using 2D U-Net Architectures.
Breast Magnetic Resonance Imaging (MRI) examinations routinely include contrast-agent based dynamic contrast-enhanced (DCE) acquisitions. Expanding the accessibility and personalization of breast MRI might be supported amongst others by advancing non-contrast-enhanced MRI, such as virtual dynamic contrast-enhanced techniques (vDCE) utilizing neural networks. This IRB-approved retrospective study includes n=540 breast MRI examinations acquired on a single 3T MRI scanner. Two 2D U-Net architectures were trained using non-contrast-enhanced MRI acquisitions including T1w, T2w and multi-b-value diffusion weighted imaging acquisitions as inputs and either a single (SCO-Net) or multiple (MCO-Net) time points of a DCE series as ground truth. The neural networks predicted a vDCE series corresponding to five consecutive DCE time points. Across all time points, no significant differences in structural similarity index (SSIM) could be found between the SCO-Net and MCO-Net, both achieving a mean SSIM of 0.86. For peak-signal-to-noise-ratio and normalized root-mean-square error, significantly better results could be observed for the MCO-Net reaching scores of 24.42dB and 0.087 respectively. Comparison of manual segmentations of findings on DCE and vDCE images reached a DICE score of 0.61 and an intersection over union (IoU) of 0.47 without significant differences between SCO-Net and MCO-Net. These findings suggest a technical feasibility of generating vDCE image series from unenhanced input acquisitions using neural networks. However, the analysis does not allow drawing any conclusion on the clinical assessment of lesion specific curve kinetics, which need to be assessed prior determining on the feasibility of deriving diagnostically meaningful enhancement characteristics in individual lesions.
- Open Access
- 3 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (13) , 1427
Stability of Radiomic Features against Variations in Lesion Segmentations Computed on Apparent Diffusion Coefficient Maps of Breast Lesions
Diffusion-weighted imaging (DWI) combined with radiomics can aid in the differentiation of breast lesions. Segmentation characteristics, however, might influence radiomic features. To evaluate feature stability, we implemented a standardized pipeline featuring shifts and shape variations of the underlying segmentations. A total of 103 patients were retrospectively included in this IRB-approved study after multiparametric diagnostic breast 3T MRI with a spin-echo diffusion-weighted sequence with echoplanar readout (b-values: 50, 750 and 1500 s/mm2). Lesion segmentations underwent shifts and shape variations, with >100 radiomic features extracted from apparent diffusion coefficient (ADC) maps for each variation. These features were then compared and ranked based on their stability, measured by the Overall Concordance Correlation Coefficient (OCCC) and Dynamic Range (DR). Results showed variation in feature robustness to segmentation changes. The most stable features, excluding shape-related features, were FO (Mean, Median, RootMeanSquared), GLDM (DependenceNonUniformity), GLRLM (RunLengthNonUniformity), and GLSZM (SizeZoneNonUniformity), which all had OCCC and DR > 0.95 for both shifting and resizing the segmentation. Perimeter, MajorAxisLength, MaximumDiameter, PixelSurface, MeshSurface, and MinorAxisLength were the most stable features in the Shape category with OCCC and DR > 0.95 for resizing. Considering the variability in radiomic feature stability against segmentation variations is relevant when interpreting radiomic analysis of breast DWI data.
- 3 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (13) , 1427
Open AccessStability of Radiomic Features against Variations in Lesion Segmentations Computed on Apparent Diffusion Coefficient Maps of Breast Lesions
Diffusion-weighted imaging (DWI) combined with radiomics can aid in the differentiation of breast lesions. Segmentation characteristics, however, might influence radiomic features. To evaluate feature stability, we implemented a standardized pipeline featuring shifts and shape variations of the underlying segmentations. A total of 103 patients were retrospectively included in this IRB-approved study after multiparametric diagnostic breast 3T MRI with a spin-echo diffusion-weighted sequence with echoplanar readout (b-values: 50, 750 and 1500 s/mm2). Lesion segmentations underwent shifts and shape variations, with >100 radiomic features extracted from apparent diffusion coefficient (ADC) maps for each variation. These features were then compared and ranked based on their stability, measured by the Overall Concordance Correlation Coefficient (OCCC) and Dynamic Range (DR). Results showed variation in feature robustness to segmentation changes. The most stable features, excluding shape-related features, were FO (Mean, Median, RootMeanSquared), GLDM (DependenceNonUniformity), GLRLM (RunLengthNonUniformity), and GLSZM (SizeZoneNonUniformity), which all had OCCC and DR > 0.95 for both shifting and resizing the segmentation. Perimeter, MajorAxisLength, MaximumDiameter, PixelSurface, MeshSurface, and MinorAxisLength were the most stable features in the Shape category with OCCC and DR > 0.95 for resizing. Considering the variability in radiomic feature stability against segmentation variations is relevant when interpreting radiomic analysis of breast DWI data.