Improved liver fat and R2* quantification at 0.55 T using locally low‐rank denoising
Open Access
- 9 October 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 1348-1364
Abstract
Purpose: To improve liver proton density fat fraction (PDFF) and quantification at 0.55 T by systematically validating the acquisition parameter choices and investigating the performance of locally low‐rank denoising methods.Methods: A Monte Carlo simulation was conducted to design a protocol for PDFF and mapping at 0.55 T. Using this proposed protocol, we investigated the performance of robust locally low‐rank (RLLR) and random matrix theory (RMT) denoising. In a reference phantom, we assessed quantification accuracy (concordance correlation coefficient [] vs. reference values) and precision (using SD) across scan repetitions. We performed in vivo liver scans (11 subjects) and used regions of interest to compare means and SDs of PDFF and measurements. Kruskal–Wallis and Wilcoxon signed‐rank tests were performed (p < 0.05 considered significant).Results: In the phantom, RLLR and RMT denoising improved accuracy in PDFF and with >0.992 and improved precision with >67% decrease in SD across 50 scan repetitions versus conventional reconstruction (i.e., no denoising). For in vivo liver scans, the mean PDFF and mean were not significantly different between the three methods (conventional reconstruction; RLLR and RMT denoising). Without denoising, the SDs of PDFF and were 8.80% and 14.17 s−1. RLLR denoising significantly reduced the values to 1.79% and 5.31 s−1 (p < 0.001); RMT denoising significantly reduced the values to 2.00% and 4.81 s−1 (p < 0.001).Conclusion: We validated an acquisition protocol for improved PDFF and quantification at 0.55 T. Both RLLR and RMT denoising improved the accuracy and precision of PDFF and measurements.Keywords
Funding Information
- National Science Foundation (1828736)
- National Institute of Biomedical Imaging and Bioengineering (U01EB031894)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK124417)
This publication has 50 references indexed in Scilit:
- Low‐field MRI: An MR physics perspectiveJournal of Magnetic Resonance Imaging, 2019
- Deep learning in radiology: An overview of the concepts and a survey of the state of the art with focus on MRIJournal of Magnetic Resonance Imaging, 2018
- Noninvasive, Quantitative Assessment of Liver Fat by MRI‐PDFF as an Endpoint in NASH TrialsHepatology, 2018
- Reproducibility of MR‐based liver fat quantification across field strength: Same‐day comparison between 1.5T and 3T in obese subjectsJournal of Magnetic Resonance Imaging, 2015
- T1 bias in chemical shift‐encoded liver fat‐fraction: Role of the flip angleJournal of Magnetic Resonance Imaging, 2013
- Effect of echo‐sampling strategy on the accuracy of out‐of‐phase and in‐phase multiecho gradient‐Echo MRI hepatic fat fraction estimationJournal of Magnetic Resonance Imaging, 2013
- Comparison of R2* correction methods for accurate fat quantification in fatty liverJournal of Magnetic Resonance Imaging, 2012
- R2* estimation using “in-phase” echoes in the presence of fat: The effects of complex spectrum of fatJournal of Magnetic Resonance Imaging, 2012
- Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopyJournal of Magnetic Resonance Imaging, 2011
- Adaptive reconstruction of phased array MR imageryMagnetic Resonance in Medicine, 2000