BTBilal Tasdelen

Bilal Tasdelen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bilal Tasdelen has a total of 28 co-authors. Here are the top co-authors by number of shared publications:

  • Krishna Shrinivas Nayak

    Ming Hsieh Department of Electrical and Computer Engineering Viterbi School of Engineering, University of Southern California Los Angeles California USA

    6 shared publications
  • Ecrin Yagiz

    Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering University of Southern California Los Angeles California USA

    3 shared publications
  • Sophia X. Cui

    Siemens Medical Solutions USA Los Angeles California USA

    3 shared publications
  • Ye Tian

    Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering University of Southern California Los Angeles California USA

    3 shared publications
  • Ergin Atalar

    Department of Electrical and Electronics Engineering‐National Magnetic Resonance Research Center (UMRAM)‐National Nanotechnology Research Center and Institute of Material Science and Nanotechnology (UNAM)‐Department of Physics, Bilkent University Ankara Turkey

    2 shared publications
  • Nam Gyun Lee

    Alfred E. Mann Department of Biomedical Engineering University of Southern California Los Angeles California USA

    2 shared publications

Latest Publications

  • Open Access

    Dynamic Mode Decomposition ( DMD ) for Low‐Latency Real‐Time Cardiac MRI

    by Ecrin Yagiz, Bilal Tasdelen, Ibrahim K. Ozaslan, Mihailo R. Jovanovic, Ye Tian, Krishna S. Nayak

    Purpose: To demonstrate dynamic mode decomposition ( DMD ) for high spatiotemporal low‐latency online reconstruction in 2D real‐time cardiac MRI. Methods: DMD was applied to 2D spiral balanced steady state free precession ( bSSFP ) real‐time adult and fetal cardiac MRI at 0.55 T, with data from 10 healthy adult volunteers (3F/7M; age: 21–49; BMI: 20–34) and 6 pregnant females (maternal age: 30–41; maternal BMI: 22–47; gestational age: 23 weeks 6 days–37 weeks 5 days). DMD model appropriateness was assessed against off‐line spatiotemporally constrained reconstruction ( STCR ) as the reference. We retrospectively evaluated DMD‐based low‐latency online reconstruction at two temporal resolutions (21 and 42 ms/frame). DMD modes were estimated from the most recently acquired frames and used to remove aliasing while preserving underlying physiological motion. Results: DMD represented cardiac dynamics with normalized root‐mean‐square error ( NRMSE ) less than 7% when all modes retained. Low‐latency DMD‐based online reconstruction performed de‐aliasing while preserving the physiological motion, supporting framerates (21 and 42 ms/frame). Conclusion: We have demonstrated that the DMD framework is applicable to 2D real‐time cardiac MRI and for low‐latency de‐aliasing for better online reconstruction.

  • Open Access

    Free‐breathing 3D pulmonary ventilation mapping at 0. 55 T using stack‐of‐spiral out‐in bSSFP

    by Ziwei Zhao, Nam G. Lee, Bilal Tasdelen, Xin Miao, Ye Tian, Bochao Li, Sophia X. Cui, Krishna S. Nayak

    Purpose: To develop a free‐breathing pulmonary imaging technique that provides three‐dimensional ( 3D) structural images and regional ventilation maps, and to evaluate its repeatability and accuracy compared with two‐dimensional phase‐resolved functional lung ( PREFUL ) and global tidal volume. Methods: A free‐breathing 3D stack‐of‐spiral out‐in ( SOS out‐in) balanced steady‐state free precession (bSSFP) sequence with self‐navigators was designed to achieve 2‐mm isotropic resolution in 5 min. Respiratory‐resolved images were reconstructed using spatial L1 wavelet and temporal finite‐difference constraints. The 3D ventilation maps were generated based on Jacobian determinant of the estimated nonrigid deformations. Six healthy volunteers were scanned in supine and prone positions. Ventilation maps were compared with two‐dimensional PREFUL from two matched slices. Test–retest repeatability was assessed using Bland–Altman analysis. Correlations among the proposed method, PREFUL, and global tidal volume were evaluated. Results: In healthy volunteers, the SOS out‐in lung images provided sufficient vessel‐parenchyma contrast and boundary sharpness to support accurate ventilation estimation. Regional ventilation measurements from 3D SOS out‐in demonstrated good repeatability (relative differences < 10%). Ventilation maps from 3D SOS out‐in strongly correlated with PREFUL on a slice‐matched basis as well as with global tidal volume ( R 2 > 0.7, p < 0.001). Conclusion: The proposed method provides high‐quality respiratory‐resolved structural images and 3D ventilation mapping in a single 5‐min scan at 0. 55 T . Ventilation measurements are sensitive, consistent, and in good agreement with PREFUL and spirometry.


  • Open Access

    Contactless cardiac gating at 0.55T using high‐amplitude pilot tone with interference cancellation (HAPTIC)

    by Bilal Tasdelen, Ecrin Yagiz, Baran R. Cinbis, Ye Tian, Krishna S. Nayak

    Purpose: To enable contactless cardiac gating at 0.55T using pilot tone (PT). Current PT methods are unable to extract weak motions, including cardiac motion, at lower B0 field strengths (<1.5T).Methods: We utilize high‐amplitude pilot tone with interference cancellation, termed HAPTIC. The use of high amplitude PT improves sensitivity to cardiac motion, but introduces noise leakage into the imaging bandwidth. This leakage is removed using External Dynamic InTerference Estimation and Removal (EDITER) interference cancellation. HAPTIC performance at 0.55T is evaluated in healthy volunteers and patients with cardiac arrhythmia, over a 100‐fold range in PT amplitude. Contactless HAPTIC gating performance is compared against conventional electrocardiogram (ECG). Noise enhancement due to HAPTIC is evaluated using noise‐only scans acquired with varying PT amplitude levels.Results: We demonstrate robust extraction of cardiac PT signals at 0.55T, with cardiac gating (ECG vs. HAPTIC) jitter <9 ms, and noise enhancement ˜12%–35%. We demonstrate the ability to track cardiac and respiratory phase during real‐time MRI and demonstrate reliable separation of cardiac and respiratory phases for retrospective binning using HAPTIC. Furthermore, we demonstrate that HAPTIC provides accurate cardiac gating in the challenging case of arrhythmia to showcase initial feasibility.Conclusion: HAPTIC enables contactless cardiac gating at 0.55T, which has not previously been demonstrated with any PT variant. This could simplify clinical workflow and could serve as a solution for mid‐ and low‐field MRI scanners that do not include built‐in physiological monitoring.


  • Open Access

    Improved liver fat and R2* quantification at 0.55 T using locally low‐rank denoising

    by Shu‐Fu Shih, Bilal Tasdelen, Ecrin Yagiz, Zhaohuan Zhang, Xiaodong Zhong, Sophia X. Cui, Krishna S. Nayak, Holden H. Wu

    Purpose: To improve liver proton density fat fraction (PDFF) and quantification at 0.55 T by systematically validating the acquisition parameter choices and investigating the performance of locally low‐rank denoising methods.Methods: A Monte Carlo simulation was conducted to design a protocol for PDFF and mapping at 0.55 T. Using this proposed protocol, we investigated the performance of robust locally low‐rank (RLLR) and random matrix theory (RMT) denoising. In a reference phantom, we assessed quantification accuracy (concordance correlation coefficient [] vs. reference values) and precision (using SD) across scan repetitions. We performed in vivo liver scans (11 subjects) and used regions of interest to compare means and SDs of PDFF and measurements. Kruskal–Wallis and Wilcoxon signed‐rank tests were performed (p < 0.05 considered significant).Results: In the phantom, RLLR and RMT denoising improved accuracy in PDFF and with >0.992 and improved precision with >67% decrease in SD across 50 scan repetitions versus conventional reconstruction (i.e., no denoising). For in vivo liver scans, the mean PDFF and mean were not significantly different between the three methods (conventional reconstruction; RLLR and RMT denoising). Without denoising, the SDs of PDFF and were 8.80% and 14.17 s−1. RLLR denoising significantly reduced the values to 1.79% and 5.31 s−1 (p < 0.001); RMT denoising significantly reduced the values to 2.00% and 4.81 s−1 (p < 0.001).Conclusion: We validated an acquisition protocol for improved PDFF and quantification at 0.55 T. Both RLLR and RMT denoising improved the accuracy and precision of PDFF and measurements.


  • T1 and T2 measurements across multiple 0.55T MRI systems using open‐source vendor‐neutral sequences

    by Kathryn E. Keenan, Bilal Tasdelen, Ahsan Javed, Rajiv Ramasawmy, Rudy Rizzo, Michele N. Martin, Karl F. Stupic, Nicole Seiberlich, Adrienne E. Campbell‐Washburn, Krishna S. Nayak

    Purpose: To compare T1 and T2 measurements across commercial and prototype 0.55T MRI systems in both phantom and healthy participants using the same vendor‐neutral pulse sequences, reconstruction, and analysis methods.Methods: Standard spin echo measurements and abbreviated protocol measurements of T1, B1, and T2 were made on two prototype 0.55 T systems and two commercial 0.55T systems using an ISMRM/NIST system phantom. Additionally, five healthy participants were imaged at each system using the abbreviated protocol for T1, B1, and T2 measurement. The phantom measurements were compared to NMR‐based reference measurements to determine accuracy, and both phantom and in vivo measurements were compared to assess reproducibility and differences between the prototype and commercial systems.Results: Vendor‐neutral sequences were implemented across all four systems, and the code for pulse sequences and reconstruction is freely available. For participants, there was no difference in the mean T1 and T2 relaxation times between the prototype and commercial systems. In the phantom, there were no significant differences between the prototype and commercial systems for T1 and T2 measurements using the abbreviated protocol.Conclusion: Quantitative T1 and T2 measurements at 0.55T in phantom and healthy participants are not statistically different across the prototype and commercial systems.


  • Open Access

    Improved abdominal T1 weighted imaging at 0.55T

    by Bilal Tasdelen, Nam G. Lee, Sophia X. Cui, Krishna S. Nayak

    Purpose: Breath‐held fat‐suppressed volumetric T1‐weighted MRI is an important and widely‐used technique for evaluating the abdomen. Both fat‐saturation and Dixon‐based fat‐suppression methods are used at conventional field strengths; however, both have challenges at lower field strengths (3) compared Cartesian Dixon (3.5 × 3.5 × 5 mm3), within a 17‐s breath‐hold. We observed successful fat suppression, and improved definition of structures such as the liver, kidneys, and bowel.Conclusion: We demonstrate that high‐resolution single breath‐hold volumetric abdominal T1‐weighted imaging is feasible at 0.55T using spiral sampling and concomitant field correction. This is an attractive alternative to existing Cartesian‐based methods, as it simultaneously provides high‐resolution and excellent fat‐suppression.


  • Analysis and mitigation of noise in simultaneous transmission and reception in MRI

    by Bilal Tasdelen, Alireza Sadeghi‐Tarakameh, Ugur Yilmaz, Ergin Atalar

    Purpose: In simultaneous transmission and reception (STAR) MRI, along with the coupling of the excitation pulse to the received signal, noise, and undesired distortions (spurs) coming from the transmit chain also leak into the acquired signal and degrade image quality. Here, properties of this coupled noise and its relationship with the transmit amplifier gain, transmit chain noise density, isolation performance, and imaging bandwidth are analyzed. It is demonstrated that by utilizing a recently proposed STAR technique, the transmit noise can be reduced. The importance of achieving high isolation and careful selection of the corresponding parameters are demonstrated.Theory and Methods: A cancellation algorithm, together with a vector modulator, is used for transmit‐receive isolation. The scanner is modeled as a pipeline of blocks to demonstrate the noise contribution from each block. With higher isolation, coupled transmit noise can be reduced to the point that the dominant noise source becomes acquisition noise, as in the case for pulsed MRI. Amplifiers with different gain and noise properties are used in the experiments to verify the derived noise‐transmit parameter relation.Results: With the proposed technique, more than 80 dB isolation in the analog domain is achieved. The leakage noise and the spurs coupled from the transmit chain, are reduced. It is shown that the transmit gain plays the most critical role in determining sufficient isolation, whereas the amplifier noise figure does not contribute as much.Conclusion: The transmit noise and the spurs in STAR imaging are analyzed and mitigated by using a vector modulator.


  • SNR Weighting for Shear Wave Speed Reconstruction in Tomoelastography

    by Cemre Ariyurek, Bilal Tasdelen, Yusuf Ziya Ider, Ergin Atalar

    In tomoelastography, to achieve a final wave speed map by combining reconstructions obtained from all spatial directions and excitation frequencies, the use of weights is inevitable. Here, a new weighting scheme, which maximizes the signal‐to‐noise ratio (SNR) of the final wave speed map, has been proposed. To maximize the SNR of the final wave speed map, the use of squares of estimated SNR values of reconstructed individual maps has been proposed. Therefore, derivations of the SNR of the reconstructed wave speed maps have become necessary. Considering the noise on the complex MRI signal, the SNR of the reconstructed wave speed map was formulated by an analytical approach assuming a high SNR, and the results were verified using Monte Carlo simulations (MCSs). It has been assumed that the noise remains approximately Gaussian when the image SNR is high enough, despite the nonlinear operations in tomoelastography inversion. Hence, the SNR threshold was determined by comparing the SNR computed by MCSs and analytical approximations. The weighting scheme was evaluated for accuracy, spatial resolution and SNR performances on simulated phantoms. MR elastography (MRE) experiments on two different phantoms were conducted. Wave speed maps were generated for simulated 3D human abdomen MRE data and experimental human abdomen MRE data. The simulation results demonstrated that the SNR‐weighted inversion improved the SNR performance of the wave speed map by a factor of two compared to the performance of the original (i.e., amplitude‐weighted) reconstruction. In the case of a low SNR, no bias occurred in the wave speed map when SNR weighting was used, whereas 10% bias occurred when the original weighting (i.e., amplitude weighting) was used. Thus, while not altering the accuracy or spatial resolution of the wave speed map with the proposed weighting method, the SNR of the wave speed map has been significantly improved.