Purpose: The aim of this paper was to investigate the relationship between the physical and subjective (observer) image quality metrics in digital chest radiography.Methods: Five digital radiography systems, four with indirect flat panel detector and one with storage phosphor‐based computed radiography system, were used in the study. The physical image quality assessments were carried out using effective detective quantum efficiency (eDQE) metric and subjective performance of the digital radiography systems was evaluated in terms of inverse image quality figure (IQFinv) derived from the contrast‐detail (CD) diagrams using CDRAD 2.0 phantom and CDRAD phantom analyzer software. All measurements were performed for different tube voltages (70, 81, 90, 102, 110, and 125 kVp) and polymethyl methacrylate (PMMA) phantom thicknesses. An anthropomorphic chest phantom and visual grading analysis (VGA) technique based on European image quality criteria for chest radiography were used for clinical image quality evaluation.Results: The Spearman correlation coefficients were calculated for the investigation of the correlation between physical image quality and clinical image quality. The results showed strong positive correlation between the physical and clinical image quality findings. The minimum correlation coefficient was 0.91 (p < 0.011) for IQFinv vs VGA scores and 0.92 (p < 0.009) for IeDQE vs VGA scores.Conclusions: Our results confirm that clinical image quality can be predicted with both physical assessments and contrast‐detail detectability studies.Keywords
This publication has 26 references indexed in Scilit:
- Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging systemBritish Journal of Radiology, 2013
- Likert scales, levels of measurement and the “laws” of statisticsAdvances in Health Sciences Education, 2010
- SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubesPhysics in Medicine & Biology, 2009
- Detector or System? Extending the Concept of Detective Quantum Efficiency to Characterize the Performance of Digital Radiographic Imaging SystemsRadiology, 2008
- Evaluation of image quality of lumbar spine images: a comparison between FFE and VGARadiation Protection Dosimetry, 2005
- Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 reportMedical Physics, 2005
- Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: Application to a new microangiographic systemMedical Physics, 2005
- Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiographyEuropean Radiology, 2003
- Methods for the Evaluation of Image Quality: A ReviewRadiation Protection Dosimetry, 2000
- Effects of dose reduction on digital chest imaging using a selenium detector: a study of detecting simulated diffuse interstitial pulmonary disease.American Journal of Roentgenology, 1996