Direct 4D PET MLEM reconstruction of parametric images using the simplified reference tissue model with the basis function method for [11C]raclopride
Authors:
- 20 May 2015
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (11) , 4533-4549
Abstract
This work assesses the one-step late maximum likelihood expectation maximization (OSL-MLEM) 4D PET reconstruction algorithm for direct estimation of parametric images from raw PET data when using the simplified reference tissue model with the basis function method (SRTM-BFM) for the kinetic analysis. To date, the OSL-MLEM method has been evaluated using kinetic models based on two-tissue compartments with an irreversible component. We extend the evaluation of this method for two-tissue compartments with a reversible component, using SRTM-BFM on simulated 3D + time data sets (with use of [ 11 C]raclopride time-activity curves from real data) and on real data sets acquired with the high resolution research tomograph. The performance of the proposed method is evaluated by comparing voxel-level binding potential ( BP ND ) estimates with those obtained from conventional post-reconstruction kinetic parameter estimation. For the commonly chosen number of iterations used in practice, our results show that for the 3D + time simulation, the direct method delivers results with lower % RMSE at the normal count level (decreases of 9–10 percentage points, corresponding to a 38–44% reduction), and also at low count levels (decreases of 17–21 percentage points, corresponding to a 26–36% reduction). As for the real 3D data set, the results obtained follow a similar trend, with the direct reconstruction method offering a 21% decrease in % CV compared to the post reconstruction method at low count levels. Thus, based on the results presented herein, using the SRTM-BFM kinetic model in conjunction with the OSL-MLEM direct 4D PET MLEM reconstruction method offers an improvement in performance when compared to conventional post reconstruction methods.Keywords
This publication has 39 references indexed in Scilit:
- Characterization of [11C]Cimbi-36 as an agonist PET radioligand for the 5-HT2A and 5-HT2C receptors in the nonhuman primate brainNeuroImage, 2014
- A positron emission tomography study of nigro-striatal dopaminergic mechanisms underlying attention: implications for ADHD and its treatmentBrain, 2013
- Direct 4D PET MLEM reconstruction of parametric images using the simplified reference tissue model with the basis function method2013
- Grey matter density and GABAA binding potential show a positive linear relationship across cortical regionsNeuroscience, 2013
- Scanning rats on the high resolution research tomograph (HRRT): A comparison study with a dedicated micro-PETMedical Physics, 2012
- Reproducibility of Striatal and Thalamic Dopamine D2 Receptor Binding Using [11C]raclopride with High-Resolution Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 2010
- A method to measure PET scatter fractions for daily quality controlMedical Physics, 2009
- OSEM-3D Reconstruction Strategies for the ECAT HRRT2005
- Bayesian reconstructions from emission tomography data using a modified EM algorithmIEEE Transactions on Medical Imaging, 1990
- Maps of receptor binding parameters in the human brain ? a kinetic analysis of PET measurementsEuropean Journal of Nuclear Medicine and Molecular Imaging, 1990