Anti-Islanding Detection Method Using Phase-Shifted Feed-Forward Voltage in Grid-Connected Inverter
Open Access
- 8 October 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 147179-147190
Abstract
For safety and maintenance problems, the grid-connected inverters have been required to detect whether the utility voltage source is connected or disconnected to the grid. If the inverter continues to energize local loads while the utility voltage source is disconnected, it is called islanding operation. This paper proposes a new islanding detection method using phase shifted feed-forward voltage. In the grid-connected inverter system, the PCC voltage is simultaneously measured, and those values are used as the feed-forward values in the current controller. In this paper, the phase of feed-forward voltage is modified to detect the islanding condition. As the measured PCC frequency changes, the proposed method modifies the phase of feed-forward voltage. Because the phase angle of feed-forward voltage is determined according to the variation of measured frequency of PCC voltage, the proposed method makes positive feedback to the frequency. If the frequency variation exceeds the allowable range, it is judged to be islanding operation. Since the frequency response of the proposed method is fast, the islanding operation could be detected in 90ms despite high quality-factor(Qf), 10. Moreover, when the grid is normal condition but grid frequency changes in allowable range, the proposed method does not produce continuous reactive power which reduces the quality of inverter output power. Lastly, proposed method has very small NDZ because there is no limitation on reactive power injection. The performance of the proposed islanding detection method was verified by a computer simulation and experiment with 600W single/three phase grid-connected inverters.Keywords
Funding Information
- Korea Institute of Energy Technology Evaluation and Planning (20163030031830)
This publication has 19 references indexed in Scilit:
- Full-Feedforward Schemes of Grid Voltages for a Three-Phase $LCL$-Type Grid-Connected InverterIEEE Transactions on Industrial Electronics, 2012
- Analysis of a hybrid controlled three-phase grid-connected inverter with harmonics compensation in synchronous reference frameIET Power Electronics, 2011
- Performance Assessment of Active Frequency Drifting Islanding Detection MethodsIEEE Transactions on Energy Conversion, 2006
- A Digital Controlled PV-Inverter With Grid Impedance Estimation for ENS DetectionIEEE Transactions on Power Electronics, 2005
- Development of a Robust Anti-Islanding Algorithm for Utility Interconnection of Distributed Fuel Cell Powered GenerationIEEE Transactions on Power Electronics, 2004
- A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation2004
- An Islanding Detection Method for Distributed Generations Using Voltage Unbalance and Total Harmonic Distortion of CurrentIEEE Transactions on Power Delivery, 2004
- A grid simulator with control of single-phase power converters in D-Q rotating frame2003
- Predicting islanding operation of gridconnected PV invertersIEE Proceedings - Electric Power Applications, 2000
- Analysis and performance assessment of the active frequency drift method of islanding preventionIEEE Transactions on Energy Conversion, 1999