DKDong-Uk Kim

Dong-Uk Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dong-Uk Kim has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of medium voltage single‐phase solid‐state transformer for high‐speed railway vehicles: Reduced scale verification results

    by Dong‐Uk Kim, Jin‐Hyuk Park, Seung‐Hwan Lee, Sungmin Kim

    This paper presents a high‐power‐density solid‐state transformer (SST) designed for 25 kV alternative current railway applications, delivering a 3 kV direct current output to traction inverters. The SST is composed of sub‐modules with the adoption of 1.7 kV insulated gate bipolar transistor and SiC metal oxide field effect transistor (MOSFET) in an input‐series–output‐series structure, providing higher power density than conventional topologies that rely on high‐voltage switches (>1.7 kV). Because these high‐voltage SiC MOSFETs are still expensive and not fully commercialised, the proposed approach offers a more cost‐effective alternative. A total of 42 converter cells ensure a highly modular and scalable design, with precise synchronisation and high‐speed control achieved through an EtherCAT‐based communication network. Additionally, a distributed control algorithm is introduced, mitigating excessive dependence on the communication link for module‐level operations. The effectiveness of the entire system—including the design and control schemes—has been experimentally verified, ranging from individual converter cells to a reduced SST prototype of up to three sub‐modules. These results confirm the feasibility and advantages of the proposed SST in terms of power density, cost efficiency and reliability for railway traction applications.


  • Design and Validation of a 100 kW, 60 kHz, High Efficiency, Loosely-Coupled-Resonant Dual-Active-Bridge Converter

    by Jaehong Lee, Dong-Uk Kim, Sungmin Kim, Seung-Hwan Lee

    A novel loosely-coupled-resonant dual-active-bridge (LCR-DAB) converter substitutes a high-frequency (HF) transformer for inductive power transfer (IPT) coils. The primary and secondary sides of the LCR-DAB converter can be separated over several centimeters for high-voltage isolation, which is the critical challenge of medium-voltage (MV) solid-state transformer (SST) systems. In this study, input impedance, zero-voltage switching (ZVS) region, output power, and efficiency of the LCR-DAB are investigated concerning operating frequency and phase-shift angle. Based on the analysis, an efficient and parameter-robust operating frequency for LCR-DAB converters is proposed. In addition, novel loosely coupled coil design guidelines for LCR-DAB converters are presented. A 1 kV, 100 kW, 60 kHz LCR-DAB test bed was fabricated for experimental evaluations. The measured coil-to-coil and dc-to-dc efficiencies were 99% and 97.3% over a 3-cm air gap. The parameter robustness and the coils' insulation performance were also evaluated.


  • A New Asymmetric Leakage Inductance for Enhancing Zero-Voltage Switching Performance in Asymmetric Triple-Active-Bridge Converters

    by Dong-Uk Kim, Dong Dong, Byoungho Kim, Sungmin Kim

    The Triple-Active Bridge (TAB) converter is a representative topology that seamlessly integrates DC sources and loads with galvanic isolation. Especially, there is a growing demand for an asymmetric TAB converter that provides distinct nominal powers at three ports, particularly in electric vehicles and power distribution systems. From the perspective of converter design, the leakage inductance is significant because it is related to Zero Voltage Switching (ZVS) of switches, and finally affects the power efficiency. Previous papers didn't consider the asymmetric TAB converter and a clear guideline of designing leakage inductance for it has not been presented. In this situation, this paper proposes a new method for determining leakage inductance for the asymmetric TAB converter. By using the proposed method, the ZVS regions in all power flow conditions are extended up to 62% more than those of the conventional method. Consequently, switching losses under light load conditions are significantly reduced, enabling the converter to attain high power efficiency in a wide range of power conditions. The unified expression of asymmetric leakage inductance is addressed through the delta equivalent model of the TAB converter, and the comprehensive analysis of ZVS is discussed. The effect of the ZVS region extension with the proposed method is verified by comparing the ZVS regions between the conventional and proposed configurations. Through the simulation model of high-power scale, switch losses are estimated in various power flow conditions, validating the feasibility of the proposed method in practical industrial applications. The performance of the proposed method is finally demonstrated through a 3kW reduced-scale TAB converter.


  • Triangular DQ Tx Coils of Wireless EV Chargers for Large Misalignment Tolerances

    by Eun S. Lee, Donguk Kim, Seog Y. Jeong

    Wireless charging of electric vehicles (EV) are inevitable for user convenience of EV charging when the EVs are parked in the charging stations. A new set of triangular DQ transmitting (Tx) coils for wireless EV chargers is newly proposed in this paper for large longitudinal, lateral, and diagonal displacement tolerances. The proposed coil set consists of two layers, i.e., D-Tx and Q-Tx, where each Tx layer has two triangular coils of the same magnetic polarity diagonally, facing each other to generate a more uniform coupling coefficient between Tx and Rx w.r.t. the misalignments. In practice, diagonal misalignment tolerance is an important design criterion to deliver load power to EV because the worst scenario of misalignment is when longitudinal and lateral misalignments occur at the same time, i.e., diagonal misalignment. To solve these misalignment issues, the DQ transmitters were optimally designed to obtain uniformed output voltage against wide range of the diagonal misalignment situations. A prototype of an inductive power transfer (IPT) system having the proposed triangular DQ Tx coils for 3.5 kW wireless EV chargers was fabricated and experimentally verified with a switching frequency of 85 kHz, which can satisfy J2954 WPT1 class in the society of automotive engineers (SAE). As a result, it is found that 8.62 of the diagonal misalignment tolerance γ d has been achieved, and this value is superior to the other Tx coils.


  • Electrode-dependent electrical switching characteristics of InGaZnO memristor

    by Woo Sik Choi, Donguk Kim, Tae Jun Yang, Inseok Chae, Changwook Kim, Hyungjin Kim, Dae Hwan Kim


  • Open Access

    Anti-Islanding Detection Method Using Phase-Shifted Feed-Forward Voltage in Grid-Connected Inverter

    by Dong-Uk Kim, Sungmin Kim

    For safety and maintenance problems, the grid-connected inverters have been required to detect whether the utility voltage source is connected or disconnected to the grid. If the inverter continues to energize local loads while the utility voltage source is disconnected, it is called islanding operation. This paper proposes a new islanding detection method using phase shifted feed-forward voltage. In the grid-connected inverter system, the PCC voltage is simultaneously measured, and those values are used as the feed-forward values in the current controller. In this paper, the phase of feed-forward voltage is modified to detect the islanding condition. As the measured PCC frequency changes, the proposed method modifies the phase of feed-forward voltage. Because the phase angle of feed-forward voltage is determined according to the variation of measured frequency of PCC voltage, the proposed method makes positive feedback to the frequency. If the frequency variation exceeds the allowable range, it is judged to be islanding operation. Since the frequency response of the proposed method is fast, the islanding operation could be detected in 90ms despite high quality-factor(Qf), 10. Moreover, when the grid is normal condition but grid frequency changes in allowable range, the proposed method does not produce continuous reactive power which reduces the quality of inverter output power. Lastly, proposed method has very small NDZ because there is no limitation on reactive power injection. The performance of the proposed islanding detection method was verified by a computer simulation and experiment with 600W single/three phase grid-connected inverters.