Case Report: Electrode perforation with normal pacemaker parameters leading to hemorrhagic shock: a rare case report of the “penetration-exit-re-entry” phenomenon
Authors:
Open Access
- 3 September 2026
- journal article
- case report
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 13, 1943190
Abstract
Background: Permanent pacemaker implantation via subclavian vein puncture may induce rare but life-threatening iatrogenic vascular injury. Vascular perforation with pacing lead penetration-exit-re-entry trajectory accompanied by normal intraoperative pacing parameters is reported extremely rarely, which greatly increases the risk of missed diagnosis. Case presentation: A 70-year-old female patient with complete atrioventricular block received dual-chamber pacemaker implantation. All intraoperative lead electrical indicators were within normal range. Immediately after the operation, she rapidly developed massive hemothorax and hemorrhagic shock with severe hypoxemia. A thoracoscopic exploration verified a unique “penetration-exit-re-entry” lesion: the pacing electrode penetrated the left subclavian vein wall, exited the vascular lumen, and re-entered the innominate vein, resulting in persistent intrathoracic bleeding. After emergency thoracic drainage, surgical venous repair and blood transfusion resuscitation, the patient's vital signs gradually stabilized and fully recovered. A 1-month follow-up showed stable pacemaker function without adverse events. Conclusion: This case highlights that normal intraoperative pacing parameters cannot rule out occult extravascular lead perforation and venous laceration. Operators should maintain high vigilance for unexplained perioperative hemodynamic collapse. Combined imaging, diagnostic thoracentesis, and early thoracoscopic surgical intervention are the core rescue strategies for this fatal complication.Keywords
This publication has 13 references indexed in Scilit:
- Impact of Procedural Aspects on Early Complications After Permanent Cardiac Implantable Device ImplantationsPacing and Clinical Electrophysiology, 2024
- Intractable late onset pacemaker endocarditis and complications case reportHeliyon, 2024
- Cough-induced sudden acute chest pain and massive left hemothorax soon after pacemaker implantationJournal of Interventional Cardiac Electrophysiology, 2023
- Intra-pocket ultrasound-guided axillary vein puncture vs. cephalic vein cutdown for cardiac electronic device implantation: the ACCESS trialEuropean Heart Journal, 2023
- An unusual cause of a haemothorax following pacemaker implantation: A case reportEuropean Heart Journal - Case Reports, 2022
- Perioperative complications after pacemaker implantation: higher complication rates with subclavian vein puncture than with cephalic vein cutdownJournal of Interventional Cardiac Electrophysiology, 2022
- 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapyEuropean Heart Journal, 2021
- Axillary vein puncture guided by ultrasound vs cephalic vein dissection in pacemaker and defibrillator implant: A multicenter randomized clinical trialHeart Rhythm, 2020
- Blunt injury of the innominate artery and left innominate veinVascular, 2011
- Blunt Rupture of the Subclavian-Innominate Venous Junction: Case Report and Review of LiteratureJournal of Trauma: Injury, Infection & Critical Care, 2009