Temperature controlled CO2 laser welding of soft tissues: Urinary bladder welding in different animal models (rats, rabbits, and cats)
Authors:
- Noam KarivNKNoam Kariv
- Abraham KatzirAKAbraham Katzir
- 14 January 2000
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 26 (1) , 4-12
Abstract
Background and Objective Laser welding of tissues is a method of closure of surgical incisions that, in principle, may have advantages over conventional closure methods. It is a noncontact technique that introduces no foreign body, the closure is continuous and watertight, and the procedure is faster and requires less skill to master. However, in practice, there have been difficulties in obtaining strong and reliable welding. We assumed that the quality of the weld depends on the ability to monitor and control the surface temperature of the welded zone during the procedure. Our objective was to develop a “smart” fiberoptic laser system for controlled temperature welding. Study Design/Materials and Methods We have developed a welding system based on a CO2 laser and on infrared transmitting AgClBr fibers. This fiberoptic system plays a double role: transmitting laser power for tissue heating and noncontact (radiometric) temperature monitoring and control. The “true” temperature of the heated tissue was determined by using an improved calibration method. We carried out long-studies of CO2 laser welding of urinary bladders in various animal models. Cystotomies were performed on the animals, and complete closure of the bladder was obtained with a surface temperature of 55 ± 5°C at the welding site. Results In early experiments on 31 rats, the success rate was 73%. In later experiments with 10 rabbits and 3 cats, there was an 80% and a 100% success rate, respectively. Conclusion The success rate in these preliminary experiments and the quality of the weld, as determined histologically, demonstrate that temperature controlled CO2 laser welding can produce effective welding of tissues. The fiberoptic system can be adapted for endoscopic laser welding. Lasers Surg. Med. 26:4–12, 2000.Keywords
This publication has 27 references indexed in Scilit:
- Effect of Optical Temperature Feedback Control on Patency in Laser-Soldered Microvascular AnastomosisJournal of Reconstructive Microsurgery, 1998
- Comparison of Fibrin Glue, Laser Weld, and Mechanical Suturing Device for the Laparoscopic Closure of Ureterotomy in a Porcine ModelJournal of Urology, 1997
- Mechanical and optical properties of silver-halide infrared transmitting fibersFiber and Integrated Optics, 1997
- Medical applications of infrared transmitting silver halide fibersIEEE Journal of Selected Topics in Quantum Electronics, 1996
- Lasers in urologyLasers in Surgery and Medicine, 1995
- Silver halide midinfrared optical fiber Y couplerOptics Letters, 1994
- Thermal feedback control techniques for transistor–transistor logic triggered CO_2 laser used for irradiation of biological tissue utilizing infrared fiber-optic radiometryApplied Optics, 1994
- Silver halide fiber optic radiometric temperature measurement and control of CO2 laser‐irradiated tissues and application to tissue weldingLasers in Surgery and Medicine, 1994
- Silver halide fiber optic radiometry for temperature monitoring and control of tissues heated by microwaveOptical Engineering, 1993
- First sutureless closure of a colotomyDiseases of the Colon & Rectum, 1991