Abraham Katzir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abraham Katzir has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
B. Dekel
Department of Physical Electronics, Faculty of Engineering, Tel Aviv University, Ramat-Aviv, Tel Aviv 69978, Israel
1 shared publicationBernard Lobel
Department of Urology, Centre Hospitalier Pontchaillou, Rennes, France
1 shared publicationNoam Kariv
1 shared publicationO. Eyal
The authors are with the Raymond and Beverly Sackler Faculty of Exact Sciences, School of Physics and Astronomy, Tel Aviv University, Tel Aviv, Israel 69978
1 shared publicationOphir Eyal
School of Physics and Astronomy, Tel Aviv University, Tel Aviv, Israel
1 shared publication
Latest Publications
- 15 October 2001
- Published by Optica Publishing Group in Optics Letters
- Vol. 26 (20) , 1553-1555
Graded-index mid-infrared planar optical waveguides made from silver halides.
Since the index of refraction of is higher than that of AgCl, by diffusing ions into AgCl it was possible to control the index and thus obtain planar waveguides made from silver chlorobromide (AgClBr) on a AgCl substrate. Silver halides are transparent in the mid IR, and it was therefore possible to characterize the waveguides by transmission of -laser radiation through them. In a typical case, the thickness was optically measured and was found to be , and the propagation loss was 16 dB/cm. The output-beam profile distribution was determined experimentally and found to be well correlated with a numerical analysis simulation based on a ray-tracing model of the eikonal equation. Planar waveguides that are transparent in the mid IR will likely be useful in numerous applications.- 15 October 2001
- Published by Optica Publishing Group in Optics Letters
- Vol. 26 (20) , 1553-1555
Graded-index mid-infrared planar optical waveguides made from silver halides.
Since the index of refraction of is higher than that of AgCl, by diffusing ions into AgCl it was possible to control the index and thus obtain planar waveguides made from silver chlorobromide (AgClBr) on a AgCl substrate. Silver halides are transparent in the mid IR, and it was therefore possible to characterize the waveguides by transmission of -laser radiation through them. In a typical case, the thickness was optically measured and was found to be , and the propagation loss was 16 dB/cm. The output-beam profile distribution was determined experimentally and found to be well correlated with a numerical analysis simulation based on a ray-tracing model of the eikonal equation. Planar waveguides that are transparent in the mid IR will likely be useful in numerous applications.- 14 January 2000
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 26 (1) , 4-12
Temperature controlled CO2 laser welding of soft tissues: Urinary bladder welding in different animal models (rats, rabbits, and cats)
Background and Objective Laser welding of tissues is a method of closure of surgical incisions that, in principle, may have advantages over conventional closure methods. It is a noncontact technique that introduces no foreign body, the closure is continuous and watertight, and the procedure is faster and requires less skill to master. However, in practice, there have been difficulties in obtaining strong and reliable welding. We assumed that the quality of the weld depends on the ability to monitor and control the surface temperature of the welded zone during the procedure. Our objective was to develop a “smart” fiberoptic laser system for controlled temperature welding. Study Design/Materials and Methods We have developed a welding system based on a CO2 laser and on infrared transmitting AgClBr fibers. This fiberoptic system plays a double role: transmitting laser power for tissue heating and noncontact (radiometric) temperature monitoring and control. The “true” temperature of the heated tissue was determined by using an improved calibration method. We carried out long-studies of CO2 laser welding of urinary bladders in various animal models. Cystotomies were performed on the animals, and complete closure of the bladder was obtained with a surface temperature of 55 ± 5°C at the welding site. Results In early experiments on 31 rats, the success rate was 73%. In later experiments with 10 rabbits and 3 cats, there was an 80% and a 100% success rate, respectively. Conclusion The success rate in these preliminary experiments and the quality of the weld, as determined histologically, demonstrate that temperature controlled CO2 laser welding can produce effective welding of tissues. The fiberoptic system can be adapted for endoscopic laser welding. Lasers Surg. Med. 26:4–12, 2000.
- 14 January 2000
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 26 (1) , 4-12
Temperature controlled CO2 laser welding of soft tissues: Urinary bladder welding in different animal models (rats, rabbits, and cats)
Background and Objective Laser welding of tissues is a method of closure of surgical incisions that, in principle, may have advantages over conventional closure methods. It is a noncontact technique that introduces no foreign body, the closure is continuous and watertight, and the procedure is faster and requires less skill to master. However, in practice, there have been difficulties in obtaining strong and reliable welding. We assumed that the quality of the weld depends on the ability to monitor and control the surface temperature of the welded zone during the procedure. Our objective was to develop a “smart” fiberoptic laser system for controlled temperature welding. Study Design/Materials and Methods We have developed a welding system based on a CO2 laser and on infrared transmitting AgClBr fibers. This fiberoptic system plays a double role: transmitting laser power for tissue heating and noncontact (radiometric) temperature monitoring and control. The “true” temperature of the heated tissue was determined by using an improved calibration method. We carried out long-studies of CO2 laser welding of urinary bladders in various animal models. Cystotomies were performed on the animals, and complete closure of the bladder was obtained with a surface temperature of 55 ± 5°C at the welding site. Results In early experiments on 31 rats, the success rate was 73%. In later experiments with 10 rabbits and 3 cats, there was an 80% and a 100% success rate, respectively. Conclusion The success rate in these preliminary experiments and the quality of the weld, as determined histologically, demonstrate that temperature controlled CO2 laser welding can produce effective welding of tissues. The fiberoptic system can be adapted for endoscopic laser welding. Lasers Surg. Med. 26:4–12, 2000.
- 20 March 1994
- Published by Optica Publishing Group in Applied Optics
- Vol. 33 (9) , 1751-1754
Thermal feedback control techniques for transistor–transistor logic triggered CO_2 laser used for irradiation of biological tissue utilizing infrared fiber-optic radiometry
A fiber-optic radiometer is used to monitor and control, in real time, the temperature of samples of biological tissue irradiated with a CO2 laser. Several control algorithms are investigated and the optimal control mode is obtained. A silver halide infrared fiber is used both to deliver the CO2 laser radiation needed to irradiate the target and to deliver the thermal radiation emitted from the target back to the radiometer. Such a system can be useful in medical applications of CO2 lasers.
- 20 March 1994
- Published by Optica Publishing Group in Applied Optics
- Vol. 33 (9) , 1751-1754
Thermal feedback control techniques for transistor–transistor logic triggered CO_2 laser used for irradiation of biological tissue utilizing infrared fiber-optic radiometry
A fiber-optic radiometer is used to monitor and control, in real time, the temperature of samples of biological tissue irradiated with a CO2 laser. Several control algorithms are investigated and the optimal control mode is obtained. A silver halide infrared fiber is used both to deliver the CO2 laser radiation needed to irradiate the target and to deliver the thermal radiation emitted from the target back to the radiometer. Such a system can be useful in medical applications of CO2 lasers.