Shearlet-based compressed sensing for fast 3D cardiac MR imaging using iterative reweighting
- 22 November 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (23) , 235004
Abstract
High-resolution three-dimensional (3D) cardiovascular magnetic resonance (CMR) is a valuable medical imaging technique, but its widespread application in clinical practice is hampered by long acquisition times. Here we present a novel compressed sensing (CS) reconstruction approach using shearlets as a sparsifying transform allowing for fast 3D CMR (3DShearCS) using 3D radial phase encoding (RPE). An iterative reweighting scheme was applied during image reconstruction to ensure fast convergence and high image quality. Shearlets are mathematically optimal for a simplified model of natural images and have been proven to be more efficient than classical systems such as wavelets. 3DShearCS was compared to three other commonly used reconstruction approaches. Image quality was assessed quantitatively using general image quality metrics and using clinical diagnostic scores from expert reviewers. The proposed technique had lower relative errors, higher structural similarity and higher diagnostic scores compared to the other reconstruction techniques especially for high undersampling factors, i.e. short scan times. 3DShearCS provided ensured accurate depiction of cardiac anatomy for fast imaging and could help to promote 3D high-resolution CMR in clinical practice.Keywords
All Related Versions
This publication has 59 references indexed in Scilit:
- Optimally Sparse Approximations of 3D Functions by Compactly Supported Shearlet FramesSIAM Journal on Mathematical Analysis, 2012
- Combination of compressed sensing and parallel imaging for highly accelerated first‐pass cardiac perfusion MRIMagnetic Resonance in Medicine, 2010
- Whole‐heart imaging using undersampled radial phase encoding (RPE) and iterative sensitivity encoding (SENSE) reconstructionMagnetic Resonance in Medicine, 2009
- Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraintMagnetic Resonance in Medicine, 2007
- Stable signal recovery from incomplete and inaccurate measurementsCommunications on Pure and Applied Mathematics, 2006
- New tight frames of curvelets and optimal representations of objects with piecewise C2 singularitiesCommunications on Pure and Applied Mathematics, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991