Novel Concept for the Expansion of the Fibula Bone as an Autologous Bone Graft: Experimental Tests on an Animal Implant Prototype—In Memoriam Volker Buehren
Open Access
- 22 March 2024
- journal article
- research article
- Published by MDPI AG in Surgical Techniques Development
- Vol. 13 (2) , 97-106
Abstract
The current reconstructive surgical procedures implemented after the resection of extended bone segments are associated with high complication rates and long-term treatments. By transplanting an autologous, vascularized and stabilized bone segment, these challenges can be managed. Thus, we propose a novel procedure to expand the currently available autologous bone grafts to the dimensions of the recipient bone using an implantable device. The objective of the present study was to characterize the feasibility of developing an implant prototype for fibula expansion in an in vitro model using a porcine fibula. A balloon catheter, as the part of the implant responsible for expansion, was proven to expand while being periodically filled with sodium chloride. Therefore, the expansion of the balloon catheter was analyzed in an experimental test setup with a 3D-printed porcine fibula with a closure film simulating callus formation to simulate the in vivo situation. Our experimental testing proved the successful expansion of the porcine fibula by the balloon catheter. Hence, the feasibility of the concept for subsequent animal testing was confirmed.Keywords
Funding Information
- German Federal Ministry for Economic Affairs and Energy (KF2100704AK2, KF2217904AK2)
This publication has 23 references indexed in Scilit:
- „All-internal“-Segmenttransport bei Knochendefekt an der Tibia: erste Erfahrungen mit dem PRECICE Bone Transport SystemDer Unfallchirurg, 2020
- Rekonstruktion von Segmentdefekten der langen RöhrenknochenTrauma und Berufskrankheit, 2015
- Reconstruction of post-traumatic long segment bone defects of the lower end of the femur by free vascularized fibula combined with allograft (modified Capanna’s technique)European Journal of Trauma and Emergency Surgery, 2014
- Pedicled vascularized fibular graft with Ilizarov external fixator for reconstructing a large bone defect of the tibia after tumor resectionJournal of Orthopaedics and Traumatology, 2013
- Risk factors for failed two-stage procedure after chronic posttraumatic periprosthetic hip infectionsArchives of orthopaedic and trauma surgery, 2012
- Does the use of an intramedullary nail alter the duration of external fixation and rate of consolidation in tibial lengthening procedures? A systematic reviewStrategies in Trauma and Limb Reconstruction, 2012
- No adverse affect after harvesting of free fibula osteoseptocutaneous flaps on gait functionMicrosurgery, 2012
- Tibial lengthening over an intramedullary nail in patients with short stature or leg-length discrepancy: a comparative studyInternational Orthopaedics, 2011
- Prinzipien der KallusdistraktionDer Unfallchirurg, 2004
- Donor-Site Morbidity after Free Vascularized Autogenous Fibular Transfer: Subjective and Quantitative AnalysesPlastic and Reconstructive Surgery, 2003