Carolin Gabler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carolin Gabler has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Rainer Bader
Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
6 shared publications - Thomas Tischer
Department of Orthopaedic Surgery, Rostock University Medical Center, Rostock, Germany
3 shared publications - Tobias Lindner
Core Facility Multimodal Small Animal Imaging, Rostock University Medical Center, Rostock, Germany
3 shared publications - Birgit Finke
Leibniz-Institute for Plasma Science and Technology e.V. (INP), Felix-Hausdorff-Str. 2, 17489 Greifswald, Germany
2 shared publications - Matthias Militz
Abteilung für Septische und Rekonstruktive Chirurgie, BG Unfallklinik Murnau, Murnau, Deutschland
2 shared publications Susann Gierschner
Rostock University Medical Center, Department of Orthopedics, Biomechanics and Implant Technology Laboratory, Rostock, Germany
2 shared publications
Latest Publications
- Open Access
- 22 March 2024
- Published by MDPI AG in Surgical Techniques Development
- Vol. 13 (2) , 97-106
Novel Concept for the Expansion of the Fibula Bone as an Autologous Bone Graft: Experimental Tests on an Animal Implant Prototype—In Memoriam Volker Buehren
The current reconstructive surgical procedures implemented after the resection of extended bone segments are associated with high complication rates and long-term treatments. By transplanting an autologous, vascularized and stabilized bone segment, these challenges can be managed. Thus, we propose a novel procedure to expand the currently available autologous bone grafts to the dimensions of the recipient bone using an implantable device. The objective of the present study was to characterize the feasibility of developing an implant prototype for fibula expansion in an in vitro model using a porcine fibula. A balloon catheter, as the part of the implant responsible for expansion, was proven to expand while being periodically filled with sodium chloride. Therefore, the expansion of the balloon catheter was analyzed in an experimental test setup with a 3D-printed porcine fibula with a closure film simulating callus formation to simulate the in vivo situation. Our experimental testing proved the successful expansion of the porcine fibula by the balloon catheter. Hence, the feasibility of the concept for subsequent animal testing was confirmed.
- 22 March 2024
- Published by MDPI AG in Surgical Techniques Development
- Vol. 13 (2) , 97-106
Open AccessNovel Concept for the Expansion of the Fibula Bone as an Autologous Bone Graft: Experimental Tests on an Animal Implant Prototype—In Memoriam Volker Buehren
The current reconstructive surgical procedures implemented after the resection of extended bone segments are associated with high complication rates and long-term treatments. By transplanting an autologous, vascularized and stabilized bone segment, these challenges can be managed. Thus, we propose a novel procedure to expand the currently available autologous bone grafts to the dimensions of the recipient bone using an implantable device. The objective of the present study was to characterize the feasibility of developing an implant prototype for fibula expansion in an in vitro model using a porcine fibula. A balloon catheter, as the part of the implant responsible for expansion, was proven to expand while being periodically filled with sodium chloride. Therefore, the expansion of the balloon catheter was analyzed in an experimental test setup with a 3D-printed porcine fibula with a closure film simulating callus formation to simulate the in vivo situation. Our experimental testing proved the successful expansion of the porcine fibula by the balloon catheter. Hence, the feasibility of the concept for subsequent animal testing was confirmed.
- Open Access
- 8 August 2018
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-11
In Vivo Evaluation of Different Collagen Scaffolds in an Achilles Tendon Defect Model
In the present study, a newly introduced bovine cross-linked collagen scaffold (test material) was investigated in vivo in an Achilles tendon defect model and compared to a commercially available porcine collagen scaffold (control material). In total, 28 male Sprague Dawley rats (about 400 g) were examined. The defined Achilles tendon defect of 5 mm of the right hind limb was replaced by one of the scaffold materials. After euthanasia, the hind limbs were transected for testing. Biomechanical evaluation was carried out via tensile testing (n = 8 each group, observation time: 28 days). Nonoperated tendons from the bilateral side were used as a control (native tendon, n = 4). For the histological evaluation, 12 animals were sacrificed at 14 and 28 days postoperatively (n = 3 each group and time point). Stained slices (Hematoxylin & Eosin) were evaluated qualitatively in terms of presence of cells and cell migration into scaffolds as well as structure and degradation of the scaffold. All transected hind limbs were additionally analyzed using MRI before testing to verify if the tendon repair using a collagen scaffold was still intact after the observation period. The maximum failure loads of both scaffold materials (test material: 54.5 ± 16.4 N, control: 63.1 ± 19.5 N) were in the range of native tendon (76.6 ± 11.6 N, p ≥ 0.07). The stiffness of native tendons was twofold higher (p ≤ 0.01) and the tear strength was approximately fivefold higher (p ≤ 0.01) compared to the repaired tendons with both scaffolds. Histological findings indicated that neither the test nor the control material induced inflammation, but the test material underwent a slower remodeling process. An overall repair failure rate of 48% was observed via MRI. The experimental data of the newly developed test material showed similar outcomes compared to the commercially available control material. The high repair failure rate indicated that MRI is recommended as an auxiliary measurement tool to validate experimental data.
- 8 August 2018
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-11
Open AccessIn Vivo Evaluation of Different Collagen Scaffolds in an Achilles Tendon Defect Model
In the present study, a newly introduced bovine cross-linked collagen scaffold (test material) was investigated in vivo in an Achilles tendon defect model and compared to a commercially available porcine collagen scaffold (control material). In total, 28 male Sprague Dawley rats (about 400 g) were examined. The defined Achilles tendon defect of 5 mm of the right hind limb was replaced by one of the scaffold materials. After euthanasia, the hind limbs were transected for testing. Biomechanical evaluation was carried out via tensile testing (n = 8 each group, observation time: 28 days). Nonoperated tendons from the bilateral side were used as a control (native tendon, n = 4). For the histological evaluation, 12 animals were sacrificed at 14 and 28 days postoperatively (n = 3 each group and time point). Stained slices (Hematoxylin & Eosin) were evaluated qualitatively in terms of presence of cells and cell migration into scaffolds as well as structure and degradation of the scaffold. All transected hind limbs were additionally analyzed using MRI before testing to verify if the tendon repair using a collagen scaffold was still intact after the observation period. The maximum failure loads of both scaffold materials (test material: 54.5 ± 16.4 N, control: 63.1 ± 19.5 N) were in the range of native tendon (76.6 ± 11.6 N, p ≥ 0.07). The stiffness of native tendons was twofold higher (p ≤ 0.01) and the tear strength was approximately fivefold higher (p ≤ 0.01) compared to the repaired tendons with both scaffolds. Histological findings indicated that neither the test nor the control material induced inflammation, but the test material underwent a slower remodeling process. An overall repair failure rate of 48% was observed via MRI. The experimental data of the newly developed test material showed similar outcomes compared to the commercially available control material. The high repair failure rate indicated that MRI is recommended as an auxiliary measurement tool to validate experimental data.
- Open Access
- 9 May 2018
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-11
Biomechanical, Biochemical, and Cell Biological Evaluation of Different Collagen Scaffolds for Tendon Augmentation
Tendon augmentation is increasingly clinically relevant due to rising amount of tendon ruptures because of the aging and more demanding population. Therefore, newly developed scaffolds based on bovine epoxide stabilized collagen maintaining the native fibril-like collagen structure were characterized and compared to two commercially available porcine collagen scaffolds. For biomechanical testing (ultimate load, ultimate stress, stiffness, and elastic modulus), bovine collagen scaffolds were hydrated and compared to reference products. Cell viability and proliferation were assessed by seeding human primary fibroblasts on each collagen-based scaffold and cultured over various time periods (3 d, 7 d, and 14 d). Live/dead staining was performed and metabolic cell activity (WST-1 assay) was measured. Biochemical degradability was investigated by enzymatic digestion. The bovine collagen scaffold showed significantly enhanced biomechanical properties. These persisted over different rehydration times. Cell biological tests revealed that the bovine collagen scaffolds support reproducible cell colonization and a significant increase in the number of viable cells during cultivation. The results are comparable with the viability and proliferation rate of cells grown on porcine reference materials. With regard to biochemical degradability, all tested materials showed comparable resistance to enzymatic degradation in vitro. Due to imitating the natural tendon structure the new scaffold material is supposed to provide beneficial effects in future clinical application.
- 9 May 2018
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-11
Open AccessBiomechanical, Biochemical, and Cell Biological Evaluation of Different Collagen Scaffolds for Tendon Augmentation
Tendon augmentation is increasingly clinically relevant due to rising amount of tendon ruptures because of the aging and more demanding population. Therefore, newly developed scaffolds based on bovine epoxide stabilized collagen maintaining the native fibril-like collagen structure were characterized and compared to two commercially available porcine collagen scaffolds. For biomechanical testing (ultimate load, ultimate stress, stiffness, and elastic modulus), bovine collagen scaffolds were hydrated and compared to reference products. Cell viability and proliferation were assessed by seeding human primary fibroblasts on each collagen-based scaffold and cultured over various time periods (3 d, 7 d, and 14 d). Live/dead staining was performed and metabolic cell activity (WST-1 assay) was measured. Biochemical degradability was investigated by enzymatic digestion. The bovine collagen scaffold showed significantly enhanced biomechanical properties. These persisted over different rehydration times. Cell biological tests revealed that the bovine collagen scaffolds support reproducible cell colonization and a significant increase in the number of viable cells during cultivation. The results are comparable with the viability and proliferation rate of cells grown on porcine reference materials. With regard to biochemical degradability, all tested materials showed comparable resistance to enzymatic degradation in vitro. Due to imitating the natural tendon structure the new scaffold material is supposed to provide beneficial effects in future clinical application.
- 1 January 2018
- Vol. 20 (2) , 73-77
Comparison of different suture techniques for Achilles tendon repair in rat model using collagen scaffolds
Purpose: Tendon injury is an increasing problem in medicine due to aging of the population and increased activity demands. Many rodent animal models are used in order to evaluate tendon reconstruction. Although tendon reruptures are a known problem, the outcomes of tendon repair in animal models are rarely discussed in the literature. The goal of the present experimental study was to compare the primary fixation stability of three suture techniques for repair of Achilles tendon defects in a rat model using a collagen scaffold. Methods: Cadaveric left hind limbs of Sprague-Dawley rats were prepared with an Achilles tendon defect of 3 mm and rejoined using a collagen scaffold. Three suture configurations (simple, simple stitch with additional framing suture, and modified Mason-Allen stitch; n = 5 each) underwent tensile testing until complete failure was observed. Results: Under a load of a mean value of 6.6 N, the failure load of simple stitches was the significantly lowest (p < 0.01) Both, modified Mason-Allen stitches and simple stitches with additional framing suture showed a mean failure load of more than 14 N. Regardless of the suture technique, most of the samples showed failure of tendon due to suture tear-out. The suture material as well as the scaffold remained mostly intact. Conclusions: Although simple end-to-end suture techniques are common in the literature, stitches with more suture strands should be preferred Using techniques like an additional framing suture or modified Mason-Allen stitch, maximum failure load can be doubled and the risk of tendon rerupture may be decreased in vivo.
- 1 January 2018
- Vol. 20 (2) , 73-77
Comparison of different suture techniques for Achilles tendon repair in rat model using collagen scaffolds
Purpose: Tendon injury is an increasing problem in medicine due to aging of the population and increased activity demands. Many rodent animal models are used in order to evaluate tendon reconstruction. Although tendon reruptures are a known problem, the outcomes of tendon repair in animal models are rarely discussed in the literature. The goal of the present experimental study was to compare the primary fixation stability of three suture techniques for repair of Achilles tendon defects in a rat model using a collagen scaffold. Methods: Cadaveric left hind limbs of Sprague-Dawley rats were prepared with an Achilles tendon defect of 3 mm and rejoined using a collagen scaffold. Three suture configurations (simple, simple stitch with additional framing suture, and modified Mason-Allen stitch; n = 5 each) underwent tensile testing until complete failure was observed. Results: Under a load of a mean value of 6.6 N, the failure load of simple stitches was the significantly lowest (p < 0.01) Both, modified Mason-Allen stitches and simple stitches with additional framing suture showed a mean failure load of more than 14 N. Regardless of the suture technique, most of the samples showed failure of tendon due to suture tear-out. The suture material as well as the scaffold remained mostly intact. Conclusions: Although simple end-to-end suture techniques are common in the literature, stitches with more suture strands should be preferred Using techniques like an additional framing suture or modified Mason-Allen stitch, maximum failure load can be doubled and the risk of tendon rerupture may be decreased in vivo.
- Open Access
- 20 October 2015
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 18 (S1) , 85-91
Rekonstruktion von Segmentdefekten der langen Röhrenknochen
- 20 October 2015
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 18 (S1) , 85-91
Open AccessRekonstruktion von Segmentdefekten der langen Röhrenknochen
- Open Access
- 1 January 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-8
Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry
A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means ofµCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined byµCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% andµCT: 51.8% and 62.0%, resp.). Mean BIC calculated byµCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 () was found between 3D and 2D quantification of BIC. TheμCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface.- 1 January 2015
- Published by Wiley in BioMed Research International
- Vol. 2015, 1-8
Open AccessQuantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry
A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means ofµCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined byµCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% andµCT: 51.8% and 62.0%, resp.). Mean BIC calculated byµCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 () was found between 3D and 2D quantification of BIC. TheμCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface. - Open Access
- 11 February 2014
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 15 (2) , 2454-2464
Evaluation of Osseointegration of Titanium Alloyed Implants Modified by Plasma Polymerization
By means of plasma polymerization, positively charged, nanometre-thin coatings can be applied to implant surfaces. The aim of the present study was to quantify the adhesion of human bone cells in vitro and to evaluate the bone ongrowth in vivo, on titanium surfaces modified by plasma polymer coatings. Different implant surface configurations were examined: titanium alloy (Ti6Al4V) coated with plasma-polymerized allylamine (PPAAm) and plasma-polymerized ethylenediamine (PPEDA) versus uncoated. Shear stress on human osteoblast-like MG-63 cells was investigated in vitro using a spinning disc device. Furthermore, bone-to-implant contact (BIC) was evaluated in vivo. Custom-made conical titanium implants were inserted at the medial tibia of female Sprague-Dawley rats. After a follow-up of six weeks, the BIC was determined by means of histomorphometry. The quantification of cell adhesion showed a significantly higher shear stress for MG-63 cells on PPAAm and PPEDA compared to uncoated Ti6Al4V. Uncoated titanium alloyed implants showed the lowest BIC (40.4%). Implants with PPAAm coating revealed a clear but not significant increase of the BIC (58.5%) and implants with PPEDA a significantly increased BIC (63.7%). In conclusion, plasma polymer coatings demonstrate enhanced cell adhesion and bone ongrowth compared to uncoated titanium surfaces.
- 11 February 2014
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 15 (2) , 2454-2464
Open AccessEvaluation of Osseointegration of Titanium Alloyed Implants Modified by Plasma Polymerization
By means of plasma polymerization, positively charged, nanometre-thin coatings can be applied to implant surfaces. The aim of the present study was to quantify the adhesion of human bone cells in vitro and to evaluate the bone ongrowth in vivo, on titanium surfaces modified by plasma polymer coatings. Different implant surface configurations were examined: titanium alloy (Ti6Al4V) coated with plasma-polymerized allylamine (PPAAm) and plasma-polymerized ethylenediamine (PPEDA) versus uncoated. Shear stress on human osteoblast-like MG-63 cells was investigated in vitro using a spinning disc device. Furthermore, bone-to-implant contact (BIC) was evaluated in vivo. Custom-made conical titanium implants were inserted at the medial tibia of female Sprague-Dawley rats. After a follow-up of six weeks, the BIC was determined by means of histomorphometry. The quantification of cell adhesion showed a significantly higher shear stress for MG-63 cells on PPAAm and PPEDA compared to uncoated Ti6Al4V. Uncoated titanium alloyed implants showed the lowest BIC (40.4%). Implants with PPAAm coating revealed a clear but not significant increase of the BIC (58.5%) and implants with PPEDA a significantly increased BIC (63.7%). In conclusion, plasma polymer coatings demonstrate enhanced cell adhesion and bone ongrowth compared to uncoated titanium surfaces.