Abstract
This study examines how the grounded and floating chamber wall boundaries affect the plasma parameters and the electron energy distribution function (EEDF) in a low-pressure, thermionically driven DC plasma. The experimental system is based on a modified double plasma device, comprising a source chamber ( φ ∼ 35 cm, l ∼ 35 cm) placed coaxially inside, at one end of a cylindrical vacuum chamber ( φ ∼ 40 cm, l ∼ 110 cm). Argon plasma was generated in the source chamber by thermionic emission and then expanded into the adjacent main chamber. The source chamber was electrically isolated from the grounded main chamber and kept either grounded or floated, depending upon the experimental conditions. EEDF and other plasma parameters were measured using three movable Langmuir probes at various locations over an operating pressure range of 10 −4 –10 −3 mbar, separately under source grounded (SG) and source floating (SF) conditions. The EEDF transitioned from a Druyvesteyn-like under SG conditions to a Maxwellian-like profile under SF conditions, delineating stronger confinement and enhanced electron-electron thermalization in the latter case. An overall higher plasma density and more uniform radial density profile was also obtained under floating boundary condition. Two-dimensional axisymmetric simulation in COMSOL Multiphysics based on a drift-diffusion model confirmed the experimentally observed increase in plasma density under floating conditions. The results highlight the critical role of boundary potential in shaping electron energy distributions, providing insights for optimizing confinement in laboratory plasma systems.

This publication has 30 references indexed in Scilit: