DSDebaprasad Sahu

Debaprasad Sahu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Debaprasad Sahu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Role of boundary wall conditions in shaping EEDF and plasma parameters in a thermionically driven low-pressure DC plasma

    by Pragya Joshi, Debaprasad Sahu

    This study examines how the grounded and floating chamber wall boundaries affect the plasma parameters and the electron energy distribution function (EEDF) in a low-pressure, thermionically driven DC plasma. The experimental system is based on a modified double plasma device, comprising a source chamber ( φ ∼ 35 cm, l ∼ 35 cm) placed coaxially inside, at one end of a cylindrical vacuum chamber ( φ ∼ 40 cm, l ∼ 110 cm). Argon plasma was generated in the source chamber by thermionic emission and then expanded into the adjacent main chamber. The source chamber was electrically isolated from the grounded main chamber and kept either grounded or floated, depending upon the experimental conditions. EEDF and other plasma parameters were measured using three movable Langmuir probes at various locations over an operating pressure range of 10 −4 –10 −3 mbar, separately under source grounded (SG) and source floating (SF) conditions. The EEDF transitioned from a Druyvesteyn-like under SG conditions to a Maxwellian-like profile under SF conditions, delineating stronger confinement and enhanced electron-electron thermalization in the latter case. An overall higher plasma density and more uniform radial density profile was also obtained under floating boundary condition. Two-dimensional axisymmetric simulation in COMSOL Multiphysics based on a drift-diffusion model confirmed the experimentally observed increase in plasma density under floating conditions. The results highlight the critical role of boundary potential in shaping electron energy distributions, providing insights for optimizing confinement in laboratory plasma systems.

  • Preliminary Investigations on Detection of Hydrogen Negative Ions at the Downstream of a Large Volume ECR Plasma Source

    by Bibekananda Naik, Shweta Sharma, Ramesh Narayanan, Debaprasad Sahu, Mainak Bandyopadhyay, Arun Chakraborty, Mahendrajit Singh, Ram Dattatraya Tarey, Ashish Ganguli

    Extraction of H- ions from plasma and their implementation in various applications such as plasma-based material processing and, most importantly, in fusion science for heating and diagnosis of thermonuclear fusion plasmas has led to significant research and development in the field of Hydrogen (H2) plasmas and negative hydrogen ion sources. The Plasma Lab, IIT Delhi which has been associated with development of a large volume Hydrogen plasma source for the past few years, has obtained the optimal downstream plasma parameters for large area production of H- ions that can be extracted for fusion applications. This paper presents preliminary studies related to the detection of negative hydrogen ions in the large-volume plasma system using a quadrupole molecular beam mass spectrometer (MBMS). Experiments were performed in a cylindrical expansion chamber with a height and diameter of 1 m. Hydrogen plasma was produced using a compact ECR microwave plasma source mounted onto the top dome of the chamber. The magnetic field configuration of the source section (cylindrical, diameter Φ = 91 mm and length, l = 110 mm) has the field strength decaying exponentially into the plasma expansion chamber of 1 m diameter. In this work, plasma was characterized under different operating conditions of microwave power (400–600 W) and gas pressure (1–3 mTorr) using a Langmuir probe that was fabricated in-house. The low-pressure plasma sampling probe of the MBMS was inserted into the expansion chamber through one of the radial ports located at z = 37.5 cm plane where z is the axial distance from the source mouth. Uniform plasma was found to be produced at that plane with density ne ∼ 6 × 1010 cm-3 and low electron temperature Te ∼ 1 eV favouring volume mode H- production. Apart from H- detection, the MBMS can be also tuned accordingly for the detection of positive ions (H+, H2 +, H3 +) and neutral (RGA mode) particles present inside the expansion chamber. Results indicate significant presence of H- ions whose intensity decreases at higher power and pressure due to dominant loss channels. The presence of low energy peak in the H- energy distribution confirms their production through the volume mode. At higher power, the low energy peak shifted towards higher energy. Correlation between plasma parameters and detected intensities are presented.


  • A 2D steady state analytical model for atmospheric pressure RF plasma jet

    by Mahreen, A Ganguli, G Veda Prakash, Satyananda Kar, Debaprasad Sahu

    This paper presents a 2-dimensional analytical model for plasma inside the discharge tube of an RF atmospheric pressure plasma jet (APPJ) in coaxial geometry. Since the model is a steady state one, it requires that the frequency of the applied RF be high enough so that the formation of streamers and plasma bullets is suppressed and that continuous plasma is present throughout the RF cycle. It is also assumed that power absorption is due to electron-atom collisions in the bulk plasma. The model takes into account gas flow, yielding a flow-diffusion axial flux that aids the exit of the plasma into the atmosphere. The inputs to the model are the reactor dimensions, average power fed (P av ) and the flow velocity of the gas (ug) using which the model yields the plasma density along with its radial and axial profiles, electron temperature, axial and radial particle fluxes, gas heating, flux, and energy of the plasma particles escaping from the discharge tube into the ambient air. Experiments were undertaken on an RF-powered jet at 13.56 MHz. Substituting the average RF power, measured using voltage and current probes, into the model gives the plasma density n ≈ 3.9 × 1017(≅2.8 × 1019)m−3 at P av ≅ 10 W ≅ 8 W for He (Ar). The corresponding electron temperature given by the model is T e ≈ 1.8 ≈ 0.8 eV , for He (Ar). It is hoped that the developed model would be able to provide a comprehensive methodology for analyzing APPJs.


  • Open Access

    Characterization of Hydrogen Plasma in an ECR based Large Volume Plasma Chamber

    by Shweta Sharma, D Sahu, R Narayanan, S Kar, M Bandyopadhyay, A Chakraborty, M J Singh, R D Tarey, A Ganguli

    Hydrogen plasma characterization was carried out in a large volume (dia∼ 1.0 m, h∼ 1.0 m) plasma chamber to evaluate the efficacy of production of uniform, large-area H- beam for fusion applications. Up to seven Compact ECR Plasma Sources (CEPS; Indian Patent #301583, Patentee: IIT Delhi) can be mounted on the top dome of the chamber (one in centre and six on a ∼60 cm dia circle). Axially poled permanent ring magnets provide the magnetic field for each CEPS and the total field in the chamber is the combined field of all CEPS. Separate experiments were conducted with: (i) six CEPS with opposite polarity on adjacent magnets, (ii) seven CEPS with identical polarity on all the magnets, and (iii) a single CEPS at the center. In case (ii) the field lines repel while for (i) a cusp field is formed between adjacent sources. For case (iii), one obtains a uniform plasma density over 35 cm radius (n ∼ 4 ϗ 1010 cm-3, Te ∼1-2 eV), ∼ 60 cm downstream (from central source mouth) with 400W power at ∼ 1-3 mTorr pressure, yielding ideal conditions for volume mode H- production over a large area. For case (ii), however, plasma from each source flows along its individual field lines, without forming uniform plasma down-tream. Whereas for case (i), because of cross-talk between adjacent sources, the system became unstable, giving oscillations in plasma formation and microwave reflected power. Hence, it appears that the single CEPS configuration is the most efficacious for large area H- generation.


  • Trapping of electrons in troughs of self generated electromagnetic standing waves in a bounded plasma column

    by Sudeep Bhattacharjee, Indranuj Dey, Krishanu Roy Chowdhury, Debaprasad Sahu, Shail Pandey, Sanghomitro Chatterjee

    Observations and measurements are reported on electron trapping in troughs of self-generated electromagnetic standing waves in a bounded plasma column confined in a minimum-B field. The boundaries are smaller than the free space wavelength of the waves. Earlier work of researchers primarily focused upon electron localization effects induced by purely electrostatic perturbation. We demonstrate the possibility in the presence of electromagnetic standing waves generated in the bounded plasma column. The electron trapping is verified with electrostatic measurements of the plasma floating potential, electromagnetic measurements of the wave field profile, and optical intensity measurements of Argon ionic line at 488 nm. The experimental results show a reasonably good agreement with predictions of a Monte Carlo simulation code that takes into account all kinematical and dynamical effects in the plasma in the presence of bounded waves and external fields.


  • Optimization of negative ion current in a compact microwave driven upper hybrid resonance multicusp plasma source

    by D. Sahu, S. Bhattacharjee, M. J. Singh, M. Bandyopadhyay, A. Chakraborty

    Performance of a microwave driven upper hybrid resonance multicusp plasma source as a volume negative ion source is reported. Microwaves are directly launched into the plasma chamber predominantly in the TE11 mode. The source is operated at different discharge conditions to obtain the optimized negative H− ion current which is ∼33 μA (0.26 mA/cm2). Particle balance equations are solved to estimate the negative ion density, which is compared with the experimental results. Future prospects of the source are discussed.