FEATURES OF USING A TWO-STAGE SERIES CONNECTION SCHEME OF DOMESTIC HOT WATER HEATERS FOR HEAT SUBSTATIONS OF INSULATED BUILDINGS
Open Access
- 23 March 2026
- journal article
- Published by O.M.Beketov National University of Urban Economy in Kharkiv
- Vol. 1 (196) , 176-182
Abstract
A comparison was performed of the district heating network water flow rate through an individual heat substation and the heat transfer surface area of the domestic hot water heating unit in an insulated building. The calculations compared a two-stage series connection scheme and a single-stage connection scheme of domestic hot water heaters to district heating networks. It is shown that the application of the two-stage series scheme, compared to the single-stage scheme, makes it possible to reduce the district heating network water flow rate through the individual heat substation by up to 50%. Achieving this effect requires increasing the heat transfer surface area of the domestic hot water heat exchangers installed in building-level heat substations by 20–78%, depending on the adopted design temperature of tap water heating at the first stage of the heating unit. The calculation results were approximated by analytical formulas. The proposed formulas take into account the possible reduction of space heating load due to building insulation, the value of the water heating temperature at the first stage of the unit, and the ratio of domestic hot water and space heating thermal loads before building insulation. From the standpoint of the thermal load distribution between the heat exchangers of the first and second stages of the heating unit and the design of the first-stage heaters, it is not advisable to adopt a tap water heating temperature at the first stage lower than 17 °C. To assess the influence of the degree of space heating load reduction due to building insulation and the tap water heating temperature at the first stage of the domestic hot water heating unit on the district heating network water flow rate and the heat transfer surface area of the heaters, formulas are proposed that approximate the calculation results with sufficient accuracy. The approximation error does not exceed 3%.Keywords
This publication has 2 references indexed in Scilit:
- ESTIMATES OF SURFACE CHANGES OF HEATING HEAT EXCHANGERS FOR INDIVIDUAL HEAT STATIONS WHEN THE TEMPERATURE CHART OF DISTRIBUTION HEAT NETWORK IS CHANGEDIntegrated Technologies and Energy Saving, 2022
- Numerical study on the effect of corrugation angle on thermal performance of cross corrugated plate heat exchangersThermal Science and Engineering Progress, 2020