    FEATURES OF USING A TWO-STAGE SERIES CONNECTION SCHEME OF DOMESTIC HOT WATER HEATERS FOR HEAT SUBSTATIONS OF INSULATED BUILDINGS

    by O. Aleksakhin, O. Boblovskyi, O. Kruhliakova, O. Gvozdetskyi

    A comparison was performed of the district heating network water flow rate through an individual heat substation and the heat transfer surface area of the domestic hot water heating unit in an insulated building. The calculations compared a two-stage series connection scheme and a single-stage connection scheme of domestic hot water heaters to district heating networks. It is shown that the application of the two-stage series scheme, compared to the single-stage scheme, makes it possible to reduce the district heating network water flow rate through the individual heat substation by up to 50%. Achieving this effect requires increasing the heat transfer surface area of the domestic hot water heat exchangers installed in building-level heat substations by 20–78%, depending on the adopted design temperature of tap water heating at the first stage of the heating unit. The calculation results were approximated by analytical formulas. The proposed formulas take into account the possible reduction of space heating load due to building insulation, the value of the water heating temperature at the first stage of the unit, and the ratio of domestic hot water and space heating thermal loads before building insulation. From the standpoint of the thermal load distribution between the heat exchangers of the first and second stages of the heating unit and the design of the first-stage heaters, it is not advisable to adopt a tap water heating temperature at the first stage lower than 17 °C. To assess the influence of the degree of space heating load reduction due to building insulation and the tap water heating temperature at the first stage of the domestic hot water heating unit on the district heating network water flow rate and the heat transfer surface area of the heaters, formulas are proposed that approximate the calculation results with sufficient accuracy. The approximation error does not exceed 3%.

  • Open Access

    COMPARISON OF HOT WATER HEATER CONNECTION SCHEMES FOR DISTRICT HEATING STATIONS IN INSULATED BUILDINGS

    by O.A. Leksakhin, O. Boblovskyi, O. Kruhliakova, M. Rudneva, O. Aleksakhin

    One way to improve efficiency micro-district centralized heat supply systems - transition from group thermal substations, where water is prepared for consumption of hot water supply, distribution of heat transfer by types of water supply, regulation of hydraulic and thermal regimes in microdistrict thermal limits, the volume of accumulated heat, up to individual district heating stations. The technological scheme of the individual district heating stations transfers all the necessary functions for the heat supply of the surrounding area construction. One of the advantages of such an approach is the possibility of transition to a two-pipe split thermal boundaries and changes in heat consumption by pipelines microdistrict boundaries A comparison was performed of the network water flow rates through individual district heating stations and the heat transfer surface area of domestic hot water heating installations in insulated buildings. The study analyzed two-stage mixed and two-stage sequential connection schemes of hot water heaters to district heating networks. It was shown that the use of two-stage schemes, as opposed to single-stage schemes, significantly reduces the network water flow through individual district heating stations. This effect is achieved by increasing the heat transfer surface area of heat exchangers in domestic hot water heating systems installed in individual district heating stations compared to single-stage schemes. For heating installations using the two-stage mixed connection scheme, larger heat transfer surface areas are expected compared to the two-stage sequential connection scheme. The excess surface area ranges from 10% to 70%, depending on the building's insulation efficiency and the design temperature for water heating at the first stage of the domestic hot water heating system. A formula was proposed to determine the water heating temperature at the first stage of the heating installation, at which the network water flow rate through the individual district heating station in the two-stage mixed scheme is lower than that in the two-stage sequential scheme. At a significant temperature rise, water heating at the first stage of the heating installation for individual district heating stations with insulation increased to more than 25℃, as a result of the increase in the total heat transfer area of the heat exchangers. installation equipment.

  • Open Access

    USE OF A TWO-STAGE COMBINED SCHEME FOR HEAT EXCHANGERS CONNECTION IN HEATING POINTS FOR HOT WATER SUPPLY OF INSULATED BUILDINGS

    by O. Aleksakhin, O. Boblovskyi, O. Kruhliakova

    The article addresses the features of the functioning of centralised heat supply systems of residential micro-districts considering the improvement of thermal insulation of existing buildings. It also analyses the performance characteristics of hot water supply heaters installed on individual heat points of insulated buildings. The authors compared the heat transfer surface area of heaters and network water flow rate through the heating point for one-stage and two-stage combined schemes of connection of heat exchangers and heat networks. The analysis of calculation results showed that using a two-stage combined connection scheme reduces the consumption of network water through the individual heat supply unit compared to the one-stage scheme. However, the two-stage scheme causes the necessity to increase the heat transfer surface area compared to the one-stage connection scheme. We generalised the results by formulas for calculating water flow rate from distribution heat networks and heat transfer surface area. It is possible to use the obtained results to develop a strategy for reforming micro-district centralised heating systems. Using a two-stage combined connection scheme for hot water supply heat exchangers installed on individual heating points (IHP) of additionally insulated buildings reduces network water consumption through the individual heating point by 8–16% compared to a one-stage connection scheme. The device of a two-stage combined scheme in comparison with a one-stage scheme causes the increase of heat transfer surface area of heat exchangers of the hot water supply of individual heating points from one and a half to two times depending on the accepted design temperature of heating of cold water at the first stage of the heating unit. The results of calculations are approximated by equations, allowing, with acceptable accuracy, to compare the indicators of two-stage combined and one-stage schemes of connection of water heaters for individual heating points of insulated buildings. Keywords: centralised heat supply, individual heating point, water heaters, hot water supply.

  • Open Access

    ANALYSIS OF HOT WATER HEATERS FOR INDIVIDUAL HEATING STATION WHEN THE TEMPERATURE CHART OF THE DISTRIBUTION HEAT NETWORK IS CHANGED

    by A. Aleksahin, A. Boblovskii, O. Kruhliakova, Y. Chaika

    The aspects of the functioning of centralized heating systems of residential urban districts after additional insulation of this district existing buildings were considered. The influence of the heat carrier temperature in the district distribution heating network on the heat transfer surface of the heat exchangers that are installed in the individual heat station schemes for hot water supplying was analyzed. Estimates were made for single-stage connection of the heat exchangers to the heating systems. When determining the heat transfer surface, known criterion equations for plate heat exchangers of heat supply systems were used. The range of changes in the heat transfer surface of hot water heaters and the consumption of network water is determined depending on the selected temperature chart of the distribution heat network. The proposed recommendations can be useful in developing a heat supply quality control schedule for a district buildings heating systems in a district when the building thermal insulation process is completed. Possible approaches to the thermal design of heat exchangers of the hot water supply system for insulated buildings individual heating stations are considered when changing the temperature chart of the district heating supply system of the residential urban districts. Estimates were made to understand the influence of the reduced temperature chart for heat supply of the districts on the network water consumption for hot water heating and the surface of heat exchangers of insulated buildings heaters. It was shown that the increase in network water consumption for building hot water supply can be 1.5 to 3 times higher. The analysis presented for the surface of the heat exchangers of heating installations for insulated buildings hot water supply shows that it can be even double increase of heaters heat transfer surface depending on the temperature chart. The results obtained should be taken into account when planning the temperature chart of the heat carrier for a distribution heating network. Keywords: district heating, heat supply systems reforming, individual heating station, hot water heaters, plate heat exchanger, heat exchanger thermal design.

  • Open Access

    Experimental Studies of the Heat Exchange Between the Water Film and the Casting Roller in the Thermal Preconditioning Chamber

    by Alexander Pereselkov, Olga Kruglyakova, Олександр Пересьолков

    When the casting roller is cooled or heated in the preconditioning chamber the water is supplied to its surface by flat-jet nozzles. The visual inspection of the model of the casting roller showed that a considerable part of it can be covered with the water film spreading from sprinkling zones. It was established that the heat conductivity in the roller body is considered to be a crucial thermal preparation factor in the conjugate heat-exchange problem for the roller of a large diameter at Bio criterion values exceeding 20. Hence, it is sufficient to provide an essential level of the heat transfer that corresponds to the heat transfer coefficient of 2000 W/(m2∙K) to provide appropriate operating conditions for the thermal preparation of the roller. The conditions are also met in sprinkling zones. Due to this fact this scientific paper studies the heat exchange conditions under the water film that spreads between the adjacent sprinkling zones. A range of changes in the flow rate of the spreading water film was determined experimentally. The conditions of heat exchange between the surface of alpha-calorimeter and the water film were analyzed depending on its flow rate and the heat meter surface temperature. A generalized correlation equation was derived. It was established that the heat exchange intensity in sprinkling zones and under the spreading water film meets technological roller treatment conditions in the preconditioning chambers. The obtained research data can be used for the rational arrangement of the collectors and flat-jet nozzles in casting roller preconditioning chambers to reduce the cold and hot water consumption and cut down operating costs.