Robustness of Post-Tensioned Concrete Beam-Column Subassemblies under Various Column Removal Scenarios
- 1 May 2022
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (5) , 04022032
Abstract
To fully recognize the load-resisting mechanisms of post-tensioned concrete (PC) structures with realistic boundary conditions against disproportionate collapse, four beam-column subassemblies were extracted from a prototype building and the side columns and joints were reproduced to reflect the actual boundary condition. The parametric analysis was conducted, including location of the removed column (middle or penultimate) and strand profile (straight or parabolic). In addition, two RC counterparts were tested as a control group. Test results indicate that the unbonded post-tensioning strand (UPS) was able to enhance the structural robustness by increasing compressive arch action capacity of RC beams and developing catenary action. Compared with RC specimens, both PC specimens achieved much higher load resistance; herein, the PC specimen with straight strand profile obtained the highest load resistance due to two strands used, while the PC specimen with parabolic profile had higher deformation capacity. However, the existence of UPS increased the tensile force demand to the side column, leading to the flexural tension failure of the side column when the loss of a penultimate column was considered. Finally, an analytical study was carried out to quantify the load resistance from each dominant load-resisting mechanism.Keywords
This publication has 24 references indexed in Scilit:
- Analytical and Experimental Evaluation of Progressive Collapse Resistance of a Flat-Slab Posttensioned Parking GarageJournal of Structural Engineering, 2015
- Influence of Concrete Compressive Strength on the Arching Behaviour of Reinforced Concrete Beam AssemblagesAdvances in Structural Engineering, 2015
- Experimental Response of Beam-Slab Substructures Subject to Penultimate-External Column RemovalJournal of Structural Engineering, 2015
- Behavior of wet precast beam column connections under progressive collapse scenario: an experimental studyInternational Journal of Advanced Structural Engineering, 2014
- Dynamic Progressive Collapse of an RC Assemblage Induced by Contact DetonationJournal of Structural Engineering, 2014
- Experimental and numerical investigation on progressive collapse resistance of reinforced concrete beam column sub-assemblagesEngineering Structures, 2013
- Development of arching action in longitudinally-restrained reinforced concrete beamsConstruction and Building Materials, 2013
- Structural Behavior of RC Beam-Column Subassemblages under a Middle Column Removal ScenarioJournal of Structural Engineering, 2013
- Progressive collapse of multi-storey buildings due to sudden column loss — Part I: Simplified assessment frameworkEngineering Structures, 2008
- Mitigating Risk from Abnormal Loads and Progressive CollapseJournal of Performance of Constructed Facilities, 2006