Dong-Qiu Lan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dong-Qiu Lan has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Feng Fu
City, Univ. of London
2 shared publications Kai Qian
2 shared publications- Kai Qian
Guilin Univ. of Technology
2 shared publications Liu Jin
2 shared publicationsJian Li
1 shared publicationLu Zhang
Professor, Guangxi Key Laboratory of New Energy and Building Energy Saving, Guilin Univ. of Technology, Guilin 541004, China
1 shared publication
Latest Publications
- 4 March 2023
- Published by Elsevier in Engineering Structures
- Vol. 283
Performance of RC beam-column assemblies during and after elevated temperature to resist progressive collapse
- 4 March 2023
- Published by Elsevier in Engineering Structures
- Vol. 283
Performance of RC beam-column assemblies during and after elevated temperature to resist progressive collapse
- 18 November 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 67
Effect of fire on behavior of RC beam-column assembly under a middle column removal scenario
- 18 November 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 67
Effect of fire on behavior of RC beam-column assembly under a middle column removal scenario
- 1 May 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (5) , 04022032
Robustness of Post-Tensioned Concrete Beam-Column Subassemblies under Various Column Removal Scenarios
To fully recognize the load-resisting mechanisms of post-tensioned concrete (PC) structures with realistic boundary conditions against disproportionate collapse, four beam-column subassemblies were extracted from a prototype building and the side columns and joints were reproduced to reflect the actual boundary condition. The parametric analysis was conducted, including location of the removed column (middle or penultimate) and strand profile (straight or parabolic). In addition, two RC counterparts were tested as a control group. Test results indicate that the unbonded post-tensioning strand (UPS) was able to enhance the structural robustness by increasing compressive arch action capacity of RC beams and developing catenary action. Compared with RC specimens, both PC specimens achieved much higher load resistance; herein, the PC specimen with straight strand profile obtained the highest load resistance due to two strands used, while the PC specimen with parabolic profile had higher deformation capacity. However, the existence of UPS increased the tensile force demand to the side column, leading to the flexural tension failure of the side column when the loss of a penultimate column was considered. Finally, an analytical study was carried out to quantify the load resistance from each dominant load-resisting mechanism.
- 1 May 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (5) , 04022032
Robustness of Post-Tensioned Concrete Beam-Column Subassemblies under Various Column Removal Scenarios
To fully recognize the load-resisting mechanisms of post-tensioned concrete (PC) structures with realistic boundary conditions against disproportionate collapse, four beam-column subassemblies were extracted from a prototype building and the side columns and joints were reproduced to reflect the actual boundary condition. The parametric analysis was conducted, including location of the removed column (middle or penultimate) and strand profile (straight or parabolic). In addition, two RC counterparts were tested as a control group. Test results indicate that the unbonded post-tensioning strand (UPS) was able to enhance the structural robustness by increasing compressive arch action capacity of RC beams and developing catenary action. Compared with RC specimens, both PC specimens achieved much higher load resistance; herein, the PC specimen with straight strand profile obtained the highest load resistance due to two strands used, while the PC specimen with parabolic profile had higher deformation capacity. However, the existence of UPS increased the tensile force demand to the side column, leading to the flexural tension failure of the side column when the loss of a penultimate column was considered. Finally, an analytical study was carried out to quantify the load resistance from each dominant load-resisting mechanism.
- 1 October 2021
- Published by Elsevier in Structures
- Vol. 33, 2534-2545
Effects of infill walls on load resistance of multi-story RC frames to mitigate progressive collapse
- 1 October 2021
- Published by Elsevier in Structures
- Vol. 33, 2534-2545
Effects of infill walls on load resistance of multi-story RC frames to mitigate progressive collapse