C-Arm Conebeam CT Perfusion Imaging in the Angiographic Suite: A Comparison with Multidetector CT Perfusion Imaging
Open Access
- 18 February 2016
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (7) , 1303-1309
Abstract
BACKGROUND AND PURPOSE: Perfusion imaging in the angiography suite may provide a way to reduce time from stroke onset to endovascular revascularization of patients with large-vessel occlusion. Our purpose was to compare conebeam CT perfusion with multidetector CT perfusion. MATERIALS AND METHODS: Data from 7 subjects with both multidetector CT perfusion and conebeam CT perfusion were retrospectively processed and analyzed. Two algorithms were used to enhance temporal resolution and temporal sampling density and reduce the noise of conebeam CT data before generating perfusion maps. Two readers performed qualitative image-quality evaluation on maps by using a 5-point scale. ROIs indicating CBF/CBV abnormalities were drawn. Quantitative analyses were performed by using the Sørensen-Dice coefficients to quantify the similarity of abnormalities. A noninferiority hypothesis was tested to compare conebeam CT perfusion against multidetector CT perfusion. RESULTS: Average image-quality scores for multidetector CT perfusion and conebeam CT perfusion images were 2.4 and 2.3, respectively. The average confidence score in diagnosis was 1.4 for both multidetector CT and conebeam CT; the average confidence scores for the presence of a CBV/CBF mismatch were 1.7 (κ = 0.50) and 1.5 (κ = 0.64). For multidetector CT perfusion and conebeam CT perfusion maps, the average scores of confidence in making treatment decisions were 1.4 (κ = 0.79) and 1.3 (κ = 0.90). The area under the visual grading characteristic for the above 4 qualitative quality scores showed an average area under visual grading characteristic of 0.50, with 95% confidence level cover centered at the mean for both readers. The Sørensen–Dice coefficient for CBF maps was 0.81, and for CBV maps, 0.55. CONCLUSIONS: After postprocessing methods were applied to enhance image quality for conebeam CT perfusion maps, the conebeam CT perfusion maps were not inferior to those generated from multidetector CT perfusion.Keywords
This publication has 15 references indexed in Scilit:
- Quantitative Dose Dependency Analysis of Whole-Brain CT Perfusion ImagingRadiology, 2016
- Flat-Panel Computed Tomography (DYNA-CT) in Neuroradiology. From High-Resolution Imaging of Implants to One-Stop-Shopping for Acute StrokeClinical Neuroradiology, 2015
- Dynamic Angiography and Perfusion Imaging Using Flat Detector CT in the Angiography Suite: A Pilot Study in Patients with Acute Middle Cerebral Artery OcclusionsAmerican Journal of Neuroradiology, 2015
- Stent-Retriever Thrombectomy after Intravenous t-PA vs. t-PA Alone in StrokeNew England Journal of Medicine, 2015
- Randomized Assessment of Rapid Endovascular Treatment of Ischemic StrokeNew England Journal of Medicine, 2015
- Endovascular Therapy for Ischemic Stroke with Perfusion-Imaging SelectionNew England Journal of Medicine, 2015
- A Randomized Trial of Intraarterial Treatment for Acute Ischemic StrokeNew England Journal of Medicine, 2015
- Denoising and artefact reduction in dynamic flat detector CT perfusion imaging using high speed acquisition: first experimental and clinical resultsPhysics in Medicine & Biology, 2014
- Toward the Era of a One-Stop Imaging Service Using an Angiography Suite for Neurovascular DisordersBioMed Research International, 2013
- Endovascular Therapy after Intravenous t-PA versus t-PA Alone for StrokeNew England Journal of Medicine, 2013