Increase of Reaction Rate and Sensitivity of Low-Abundance Enzyme Assay Using Micro/Nanofluidic Preconcentration Chip
- 22 March 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (9) , 3198-3204
Abstract
We report a novel method of increasing both the reaction rate and the sensitivity of low-abundance enzyme assay using a micro/nanofluidic preconcentration chip. The disposable preconcentration device made out of PDMS with a surface-patterned ion-selective membrane increases local enzyme/substrate concentrations for rapid monitoring of enzyme activity. As a model system, we used trypsin as the enzyme and BODIPY FL casein as the fluorogenic substrate. We demonstrated that the reaction rate of trypsin−BODIPY FL was significantly enhanced by increasing the local concentrations of both trypsin and BODIPY FL casein in the preconcentration chip. The reaction time required to turn over substrates at 1 ng/mL was only ∼10 min compared to ∼1 h without preconcentration, which demonstrates a significantly higher reaction rate through the increase of the concentrations of both the enzyme and substrate. Furthermore, trypsin activity can be measured down to a concentration level of 10 pg/mL, which is a ∼100 fold enhancement in sensitivity compared to the result without the preconcentration step. This micro/nanofluidic preconcentrator chip could be used as a generic micro reaction platform to study any enzyme−substrate systems, or other biochemical reaction systems in low concentration ranges.Keywords
This publication has 24 references indexed in Scilit:
- Multiplexed proteomic sample preconcentration device using surface-patterned ion-selective membraneLab on a Chip, 2008
- Poly(dimethylsiloxane)-Based Protein Preconcentration Using a Nanogap Generated by Junction Gap BreakdownAnalytical Chemistry, 2007
- Polymer surface modification for the attachment of bioactive compoundsProgress in Polymer Science, 2007
- Electrokinetic Protein Preconcentration Using a Simple Glass/Poly(dimethylsiloxane) Microfluidic ChipAnalytical Chemistry, 2006
- Enzyme Immobilization in Porous Silicon: Quantitative Analysis of the Kinetic Parameters for Glutathione-S-transferasesAnalytical Chemistry, 2005
- Patterning Enzymes Inside Microfluidic Channels via Photoattachment ChemistryAnalytical Chemistry, 2004
- A High-throughput Quantitative Multiplex Kinase Assay for Monitoring Information Flow in Signaling NetworksMolecular & Cellular Proteomics, 2003
- Altered Cytokine Export and Apoptosis in Mice Deficient in Interleukin-1β Converting EnzymeScience, 1995
- Induction of apoptosis in fibroblasts by IL-1β-converting enzyme, a mammalian homolog of the C. elegans cell death gene ced-3Cell, 1993
- Serum Enzyme Determinations in the Diagnosis and Assessment of Myocardial InfarctionCirculation, 1972