A Multi-Criteria Assessment Strategy for 3D Printed Porous Polyetheretherketone (PEEK) Patient-Specific Implants for Orbital Wall Reconstruction
Open Access
- 13 August 2021
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (16) , 3563
Abstract
Pure orbital blowout fractures occur within the confines of the internal orbital wall. Restoration of orbital form and volume is paramount to prevent functional and esthetic impairment. The anatomical peculiarity of the orbit has encouraged surgeons to develop implants with customized features to restore its architecture. This has resulted in worldwide clinical demand for patient-specific implants (PSIs) designed to fit precisely in the patient’s unique anatomy. Material extrusion or Fused filament fabrication (FFF) three-dimensional (3D) printing technology has enabled the fabrication of implant-grade polymers such as Polyetheretherketone (PEEK), paving the way for a more sophisticated generation of biomaterials. This study evaluates the FFF 3D printed PEEK orbital mesh customized implants with a metric considering the relevant design, biomechanical, and morphological parameters. The performance of the implants is studied as a function of varying thicknesses and porous design constructs through a finite element (FE) based computational model and a decision matrix based statistical approach. The maximum stress values achieved in our results predict the high durability of the implants, and the maximum deformation values were under one-tenth of a millimeter (mm) domain in all the implant profile configurations. The circular patterned implant (0.9 mm) had the best performance score. The study demonstrates that compounding multi-design computational analysis with 3D printing can be beneficial for the optimal restoration of the orbital floor.Keywords
All Related Versions
This publication has 66 references indexed in Scilit:
- Biomaterials for Repair of Orbital Floor Blowout Fractures: A Systematic ReviewJournal of Oral and Maxillofacial Surgery, 2013
- Materials Used for Reconstruction After Orbital Floor FractureJournal of Craniofacial Surgery, 2012
- Maximum Forces Applied to the Orbital Floor After FracturesJournal of Craniofacial Surgery, 2012
- Mechanical characterization and numerical simulation of polyether–ether–ketone (PEEK) cranial implantsJournal of the Mechanical Behavior of Biomedical Materials, 2011
- Biomaterials and implants for orbital floor repairActa Biomaterialia, 2011
- Comparison of the Outcomes of Blowout Fracture Repair According to the Orbital ImplantJournal of Craniofacial Surgery, 2011
- Comparison of the Supporting Strength of a Poly-l-Lactic Acid Sheet and Porous Polyethylene (Medpor) for the Reconstruction of Orbital Floor FracturesJournal of Craniofacial Surgery, 2010
- Analysis of Orbital Bone FracturesJournal of Craniofacial Surgery, 2009
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007