Hans-Florian Zeilhofer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hans-Florian Zeilhofer has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Britt-Isabelle Berg
Department of Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, 4031 Basel, Switzerland
4 shared publications - Florian Markus Thieringer
Department of Oral and Cranio-Maxillofacial Surgery and 3D Print Lab, University Hospital Basel, 4031 Basel, Switzerland
3 shared publications - Neha Sharma
Clinic of Oral and Cranio-Maxillofacial Surgery and 3D Print Lab, University Hospital Basel, Basel, Switzerland
3 shared publications - Philipp Honigmann
Hand and Peripheral Nerve Surgery, Department of Orthopaedic and Trauma Surgery, Kantonsspital Baselland, Liestal, Switzerland
2 shared publications - Robert Sader
University Hospital Frankfurt, Goethe-University Frankfur
2 shared publications - Soheila Aghlmandi
Basel Institute for Clinical Epidemiology and Biostatistics, Department of Clinical Research, University Hospital Basel, CH-4031 Basel, Switzerland
2 shared publications
Latest Publications
- Open Access
- 13 August 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (16) , 3563
A Multi-Criteria Assessment Strategy for 3D Printed Porous Polyetheretherketone (PEEK) Patient-Specific Implants for Orbital Wall Reconstruction
Pure orbital blowout fractures occur within the confines of the internal orbital wall. Restoration of orbital form and volume is paramount to prevent functional and esthetic impairment. The anatomical peculiarity of the orbit has encouraged surgeons to develop implants with customized features to restore its architecture. This has resulted in worldwide clinical demand for patient-specific implants (PSIs) designed to fit precisely in the patient’s unique anatomy. Material extrusion or Fused filament fabrication (FFF) three-dimensional (3D) printing technology has enabled the fabrication of implant-grade polymers such as Polyetheretherketone (PEEK), paving the way for a more sophisticated generation of biomaterials. This study evaluates the FFF 3D printed PEEK orbital mesh customized implants with a metric considering the relevant design, biomechanical, and morphological parameters. The performance of the implants is studied as a function of varying thicknesses and porous design constructs through a finite element (FE) based computational model and a decision matrix based statistical approach. The maximum stress values achieved in our results predict the high durability of the implants, and the maximum deformation values were under one-tenth of a millimeter (mm) domain in all the implant profile configurations. The circular patterned implant (0.9 mm) had the best performance score. The study demonstrates that compounding multi-design computational analysis with 3D printing can be beneficial for the optimal restoration of the orbital floor.
- 13 August 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (16) , 3563
Open AccessA Multi-Criteria Assessment Strategy for 3D Printed Porous Polyetheretherketone (PEEK) Patient-Specific Implants for Orbital Wall Reconstruction
Pure orbital blowout fractures occur within the confines of the internal orbital wall. Restoration of orbital form and volume is paramount to prevent functional and esthetic impairment. The anatomical peculiarity of the orbit has encouraged surgeons to develop implants with customized features to restore its architecture. This has resulted in worldwide clinical demand for patient-specific implants (PSIs) designed to fit precisely in the patient’s unique anatomy. Material extrusion or Fused filament fabrication (FFF) three-dimensional (3D) printing technology has enabled the fabrication of implant-grade polymers such as Polyetheretherketone (PEEK), paving the way for a more sophisticated generation of biomaterials. This study evaluates the FFF 3D printed PEEK orbital mesh customized implants with a metric considering the relevant design, biomechanical, and morphological parameters. The performance of the implants is studied as a function of varying thicknesses and porous design constructs through a finite element (FE) based computational model and a decision matrix based statistical approach. The maximum stress values achieved in our results predict the high durability of the implants, and the maximum deformation values were under one-tenth of a millimeter (mm) domain in all the implant profile configurations. The circular patterned implant (0.9 mm) had the best performance score. The study demonstrates that compounding multi-design computational analysis with 3D printing can be beneficial for the optimal restoration of the orbital floor.
- Top Cited PapersOpen Access
- 7 August 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (16) , 8521
Quantitative Assessment of Point-of-Care 3D-Printed Patient-Specific Polyetheretherketone (PEEK) Cranial Implants
Recent advancements in medical imaging, virtual surgical planning (VSP), and three-dimensional (3D) printing have potentially changed how today’s craniomaxillofacial surgeons use patient information for customized treatments. Over the years, polyetheretherketone (PEEK) has emerged as the biomaterial of choice to reconstruct craniofacial defects. With advancements in additive manufacturing (AM) systems, prospects for the point-of-care (POC) 3D printing of PEEK patient-specific implants (PSIs) have emerged. Consequently, investigating the clinical reliability of POC-manufactured PEEK implants has become a necessary endeavor. Therefore, this paper aims to provide a quantitative assessment of POC-manufactured, 3D-printed PEEK PSIs for cranial reconstruction through characterization of the geometrical, morphological, and biomechanical aspects of the in-hospital 3D-printed PEEK cranial implants. The study results revealed that the printed customized cranial implants had high dimensional accuracy and repeatability, displaying clinically acceptable morphologic similarity concerning fit and contours continuity. From a biomechanical standpoint, it was noticed that the tested implants had variable peak load values with discrete fracture patterns and failed at a mean (SD) peak load of 798.38 ± 211.45 N. In conclusion, the results of this preclinical study are in line with cranial implant expectations; however, specific attributes have scope for further improvements.
- 7 August 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (16) , 8521
Top Cited PapersOpen AccessQuantitative Assessment of Point-of-Care 3D-Printed Patient-Specific Polyetheretherketone (PEEK) Cranial Implants
Recent advancements in medical imaging, virtual surgical planning (VSP), and three-dimensional (3D) printing have potentially changed how today’s craniomaxillofacial surgeons use patient information for customized treatments. Over the years, polyetheretherketone (PEEK) has emerged as the biomaterial of choice to reconstruct craniofacial defects. With advancements in additive manufacturing (AM) systems, prospects for the point-of-care (POC) 3D printing of PEEK patient-specific implants (PSIs) have emerged. Consequently, investigating the clinical reliability of POC-manufactured PEEK implants has become a necessary endeavor. Therefore, this paper aims to provide a quantitative assessment of POC-manufactured, 3D-printed PEEK PSIs for cranial reconstruction through characterization of the geometrical, morphological, and biomechanical aspects of the in-hospital 3D-printed PEEK cranial implants. The study results revealed that the printed customized cranial implants had high dimensional accuracy and repeatability, displaying clinically acceptable morphologic similarity concerning fit and contours continuity. From a biomechanical standpoint, it was noticed that the tested implants had variable peak load values with discrete fracture patterns and failed at a mean (SD) peak load of 798.38 ± 211.45 N. In conclusion, the results of this preclinical study are in line with cranial implant expectations; however, specific attributes have scope for further improvements.
- Open Access
- 24 January 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (3) , 450
Cold Ablation Robot-Guided Laser Osteotome (CARLO®): From Bench to Bedside
Background: In order to overcome the geometrical and physical limitations of conventional rotating and piezosurgery instruments used to perform bone osteotomies, as well as the difficulties in translating digital planning to the operating room, a stand-alone robot-guided laser system has been developed by Advanced Osteotomy Tools, a Swiss start-up company. We present our experiences of the first-in-man use of the Cold Ablation Robot-guided Laser Osteotome (CARLO®). Methods: The CARLO® device employs a stand-alone 2.94-µm erbium-doped yttrium aluminum garnet (Er:YAG) laser mounted on a robotic arm. A 19-year-old patient provided informed consent to undergo bimaxillary orthognathic surgery. A linear Le Fort I midface osteotomy was digitally planned and transferred to the CARLO® device. The linear part of the Le Fort I osteotomy was performed autonomously by the CARLO® device under direct visual control. All pre-, intra-, and postoperative technical difficulties and safety issues were documented. Accuracy was analyzed by superimposing pre- and postoperative computed tomography images. Results: The CARLO® device performed the linear osteotomy without any technical or safety issues. There was a maximum difference of 0.8 mm between the planned and performed osteotomies, with a root-mean-square error of 1.0 mm. The patient showed normal postoperative healing with no complications. Conclusion: The newly developed stand-alone CARLO® device could be a useful alternative to conventional burs, drills, and piezosurgery instruments for performing osteotomies. However, the technical workflow concerning the positioning and fixation of the target marker and the implementation of active depth control still need to be improved. Further research to assess safety and accuracy is also necessary, especially at osteotomy sites where direct visual control is not possible. Finally, cost-effectiveness analysis comparing the use of the CARLO® device with gold-standard surgery protocols will help to define the role of the CARLO® device in the surgical landscape.
- 24 January 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (3) , 450
Open AccessCold Ablation Robot-Guided Laser Osteotome (CARLO®): From Bench to Bedside
Background: In order to overcome the geometrical and physical limitations of conventional rotating and piezosurgery instruments used to perform bone osteotomies, as well as the difficulties in translating digital planning to the operating room, a stand-alone robot-guided laser system has been developed by Advanced Osteotomy Tools, a Swiss start-up company. We present our experiences of the first-in-man use of the Cold Ablation Robot-guided Laser Osteotome (CARLO®). Methods: The CARLO® device employs a stand-alone 2.94-µm erbium-doped yttrium aluminum garnet (Er:YAG) laser mounted on a robotic arm. A 19-year-old patient provided informed consent to undergo bimaxillary orthognathic surgery. A linear Le Fort I midface osteotomy was digitally planned and transferred to the CARLO® device. The linear part of the Le Fort I osteotomy was performed autonomously by the CARLO® device under direct visual control. All pre-, intra-, and postoperative technical difficulties and safety issues were documented. Accuracy was analyzed by superimposing pre- and postoperative computed tomography images. Results: The CARLO® device performed the linear osteotomy without any technical or safety issues. There was a maximum difference of 0.8 mm between the planned and performed osteotomies, with a root-mean-square error of 1.0 mm. The patient showed normal postoperative healing with no complications. Conclusion: The newly developed stand-alone CARLO® device could be a useful alternative to conventional burs, drills, and piezosurgery instruments for performing osteotomies. However, the technical workflow concerning the positioning and fixation of the target marker and the implementation of active depth control still need to be improved. Further research to assess safety and accuracy is also necessary, especially at osteotomy sites where direct visual control is not possible. Finally, cost-effectiveness analysis comparing the use of the CARLO® device with gold-standard surgery protocols will help to define the role of the CARLO® device in the surgical landscape.
- Open Access
- 26 October 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3424
Comparison of the Visibility of Fetal Tooth Buds on 1.5 and 3 Tesla MRI
Dental anomalies coincide with genetic disorders, and prenatal identification may contribute to a more accurate diagnosis. The aim of this study was to assess whether fetal Magnet Resonance Imaging (MRI) is suitable to visualize and investigate intrauterine dental development in the upper jaw, and to compare the quality of visibility of tooth buds between 1.5 Tesla (T) and 3T images. MR images of fetuses Gestational Week (GW) 26.71 ± 4.97 from 286 pregnant women with diagnoses unrelated to dental anomalies were assessed by three raters. We compared the visibility between groups and field strengths in five gestational age groups, using chi square and Fisher’s exact tests. All ten primary tooth buds were identifiable in 5.4% at GW 18–21, in 75.5% at GW 26–29, and in 90.6% at GW 34+. Before GW 30, more tooth buds were identifiable on 3T images than on 1.5T images. Statistical significance was only reached for identification of incisors (p = 0.047). Therefore, 1.5T and 3T images are viable to visualize tooth buds, particularly after GW 25, and their analysis may serve as diagnostic criterion. MRI tooth bud data might have an impact on various fields of research, such as the maldevelopment of teeth and their causes. Analyzing tooth buds as an additional diagnostic criterion is not time consuming, and could lead to an improvement of syndrome diagnosis.
- 26 October 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (11) , 3424
Open AccessComparison of the Visibility of Fetal Tooth Buds on 1.5 and 3 Tesla MRI
Dental anomalies coincide with genetic disorders, and prenatal identification may contribute to a more accurate diagnosis. The aim of this study was to assess whether fetal Magnet Resonance Imaging (MRI) is suitable to visualize and investigate intrauterine dental development in the upper jaw, and to compare the quality of visibility of tooth buds between 1.5 Tesla (T) and 3T images. MR images of fetuses Gestational Week (GW) 26.71 ± 4.97 from 286 pregnant women with diagnoses unrelated to dental anomalies were assessed by three raters. We compared the visibility between groups and field strengths in five gestational age groups, using chi square and Fisher’s exact tests. All ten primary tooth buds were identifiable in 5.4% at GW 18–21, in 75.5% at GW 26–29, and in 90.6% at GW 34+. Before GW 30, more tooth buds were identifiable on 3T images than on 1.5T images. Statistical significance was only reached for identification of incisors (p = 0.047). Therefore, 1.5T and 3T images are viable to visualize tooth buds, particularly after GW 25, and their analysis may serve as diagnostic criterion. MRI tooth bud data might have an impact on various fields of research, such as the maldevelopment of teeth and their causes. Analyzing tooth buds as an additional diagnostic criterion is not time consuming, and could lead to an improvement of syndrome diagnosis.
- Top Cited PapersOpen Access
- 17 March 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (3) , 817
Evaluation of the Dimensional Accuracy of 3D-Printed Anatomical Mandibular Models Using FFF, SLA, SLS, MJ, and BJ Printing Technology
With the rapid progression of additive manufacturing and the emergence of new 3D printing technologies, accuracy assessment is mostly being performed on isosymmetric-shaped test bodies. However, the accuracy of anatomic models can vary. The dimensional accuracy of root mean square values in terms of trueness and precision of 50 mandibular replicas, printed with five common printing technologies, were evaluated. The highest trueness was found for the selective laser sintering printer (0.11 ± 0.016 mm), followed by a binder jetting printer (0.14 ± 0.02 mm), and a fused filament fabrication printer (0.16 ± 0.009 mm). However, highest precision was identified for the fused filament fabrication printer (0.05 ± 0.005 mm) whereas other printers had marginally lower values. Despite the statistically significance (p < 0.001), these differences can be considered clinically insignificant. These findings demonstrate that all 3D printing technologies create models with satisfactory dimensional accuracy for surgical use. Since satisfactory results in terms of accuracy can be reached with most technologies, the choice should be more strongly based on the printing materials, the intended use, and the overall budget. The simplest printing technology (fused filament fabrication) always scored high and thus is a reliable choice for most purposes.
- 17 March 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (3) , 817
Top Cited PapersOpen AccessEvaluation of the Dimensional Accuracy of 3D-Printed Anatomical Mandibular Models Using FFF, SLA, SLS, MJ, and BJ Printing Technology
With the rapid progression of additive manufacturing and the emergence of new 3D printing technologies, accuracy assessment is mostly being performed on isosymmetric-shaped test bodies. However, the accuracy of anatomic models can vary. The dimensional accuracy of root mean square values in terms of trueness and precision of 50 mandibular replicas, printed with five common printing technologies, were evaluated. The highest trueness was found for the selective laser sintering printer (0.11 ± 0.016 mm), followed by a binder jetting printer (0.14 ± 0.02 mm), and a fused filament fabrication printer (0.16 ± 0.009 mm). However, highest precision was identified for the fused filament fabrication printer (0.05 ± 0.005 mm) whereas other printers had marginally lower values. Despite the statistically significance (p < 0.001), these differences can be considered clinically insignificant. These findings demonstrate that all 3D printing technologies create models with satisfactory dimensional accuracy for surgical use. Since satisfactory results in terms of accuracy can be reached with most technologies, the choice should be more strongly based on the printing materials, the intended use, and the overall budget. The simplest printing technology (fused filament fabrication) always scored high and thus is a reliable choice for most purposes.
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 507-510
Computer assisted assessment of progressing osteoradionecrosis of the jaw for clinical diagnosis and treatment
Osteoradionecrosis (ORN) is a serious side effect of oncologic radiation therapy. Often, surgical removal of the affected skeletal tissue is indicated. In cranio-maxillofacial surgery, partial or total resection of the upper or lower jaw implies a severe impairment of the patient‘s quality of life. Up to now, clear display of ORN is still a challenge. This part of the project is dedicated to medical visualization of progressing ORN for clinical diagnosis. Currently, clinical diagnosis of ORN is mostly based on computer tomography (CT). With regard to its high advantages as e.g. reduced radiation dose, we additionally evaluate cone beam computer tomography (CBCT). After registration on a suitable reference and refined image processing and segmentation, all patient’s CT-/CBCT-data are subjected to various rendering techniques configured for the respective purpose, namely visualization of destructive and/or sclerotic skeletal alterations, consideration of cortical or trabecular bone, and analysis based on CT or CBCT. Recent achievements within the project were demonstrated with special focus on evaluation of both, CT and CBCT as well as on close cooperation with the clinical setting.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 507-510
Open AccessComputer assisted assessment of progressing osteoradionecrosis of the jaw for clinical diagnosis and treatment
Osteoradionecrosis (ORN) is a serious side effect of oncologic radiation therapy. Often, surgical removal of the affected skeletal tissue is indicated. In cranio-maxillofacial surgery, partial or total resection of the upper or lower jaw implies a severe impairment of the patient‘s quality of life. Up to now, clear display of ORN is still a challenge. This part of the project is dedicated to medical visualization of progressing ORN for clinical diagnosis. Currently, clinical diagnosis of ORN is mostly based on computer tomography (CT). With regard to its high advantages as e.g. reduced radiation dose, we additionally evaluate cone beam computer tomography (CBCT). After registration on a suitable reference and refined image processing and segmentation, all patient’s CT-/CBCT-data are subjected to various rendering techniques configured for the respective purpose, namely visualization of destructive and/or sclerotic skeletal alterations, consideration of cortical or trabecular bone, and analysis based on CT or CBCT. Recent achievements within the project were demonstrated with special focus on evaluation of both, CT and CBCT as well as on close cooperation with the clinical setting.
- 1 December 2015
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 53 (10) , 976-981
Clinical applicability of robot-guided contact-free laser osteotomy in cranio-maxillo-facial surgery: in-vitro simulation and in-vivo surgery in minipig mandibles
- 1 December 2015
- Published by Elsevier in British Journal of Oral and Maxillofacial Surgery
- Vol. 53 (10) , 976-981
Clinical applicability of robot-guided contact-free laser osteotomy in cranio-maxillo-facial surgery: in-vitro simulation and in-vivo surgery in minipig mandibles
- 1 January 2014
- Vol. 124 (4) , 419-33
[Cone beam computed tomography and radiation dosage: application frequency and knowledge of dentists in Switzerland].
The use of cone beam computed tomography (CBCT) among Swiss dentists increases from year to year. The aim of this study was to investigate the application frequency and the knowledge about CBCT and radiation dosage in a representative Swiss dentist sample. A standardized questionnaire about knowledge on CBCT was personally handed out or sent by post to 1,000 dentists in Switzerland (return postage was free of charge). 278 dentists returned the questionnaire. Descriptive statistics, correlation analysis of general variables and written answers of the questionnaires were evaluated. Most dentists were aware of radiation dosage and potential use of the CBCT and are interested in continuing education on CBCT.
- 1 January 2014
- Vol. 124 (4) , 419-33
[Cone beam computed tomography and radiation dosage: application frequency and knowledge of dentists in Switzerland].
The use of cone beam computed tomography (CBCT) among Swiss dentists increases from year to year. The aim of this study was to investigate the application frequency and the knowledge about CBCT and radiation dosage in a representative Swiss dentist sample. A standardized questionnaire about knowledge on CBCT was personally handed out or sent by post to 1,000 dentists in Switzerland (return postage was free of charge). 278 dentists returned the questionnaire. Descriptive statistics, correlation analysis of general variables and written answers of the questionnaires were evaluated. Most dentists were aware of radiation dosage and potential use of the CBCT and are interested in continuing education on CBCT.
- 1 January 2007
- Vol. 117 (9) , 911-9
[Early detection and prevention of oral precancer. An enquiry among dentists in Switzerland].
Squamous cell carcinoma ranks eighth among the most common tumors worldwide. In many cases, these tumors develop from a preliminary phase (precancerosis). For different reasons, these preinitial carcinomas are recognised too late or not at all. The aim of this study was to find out about the dentists' state of knowledge, their management of these tumors and their readiness for a prevention campaign among Swiss dentists. 800 questionnaires were mailed or handed out to dentists nationwide. 22% of the questionnaires were returned. 64% of the dentists stated to be highly motivated for further education and 81% were willing to participate in a prevention campaign. 94% of the dentists examine the oral mucosa inclusive the (palatine) tonsil bed at least once a year, but only 15% of the participating dentists discuss the risk factors like alcohol or tobacco consumption with their patients. The most common factors which inhibit prevention in daily routine are the patients' refusal, a lack of education in that field, absence of information flyers and lack of time. A primary and secondary prevention program would be preferable to achieve a decrease in the incidence rate of squamous cell carcinoma.
- 1 January 2007
- Vol. 117 (9) , 911-9
[Early detection and prevention of oral precancer. An enquiry among dentists in Switzerland].
Squamous cell carcinoma ranks eighth among the most common tumors worldwide. In many cases, these tumors develop from a preliminary phase (precancerosis). For different reasons, these preinitial carcinomas are recognised too late or not at all. The aim of this study was to find out about the dentists' state of knowledge, their management of these tumors and their readiness for a prevention campaign among Swiss dentists. 800 questionnaires were mailed or handed out to dentists nationwide. 22% of the questionnaires were returned. 64% of the dentists stated to be highly motivated for further education and 81% were willing to participate in a prevention campaign. 94% of the dentists examine the oral mucosa inclusive the (palatine) tonsil bed at least once a year, but only 15% of the participating dentists discuss the risk factors like alcohol or tobacco consumption with their patients. The most common factors which inhibit prevention in daily routine are the patients' refusal, a lack of education in that field, absence of information flyers and lack of time. A primary and secondary prevention program would be preferable to achieve a decrease in the incidence rate of squamous cell carcinoma.
- 1 January 1997
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 42 (s2) , 211-212
Diagnostische Möglichkeiten der dreidimensionalen Darstellung sonographischer Bilddaten in der Mund-, Kiefer- und Gesichtschirurgie
- 1 January 1997
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 42 (s2) , 211-212
Diagnostische Möglichkeiten der dreidimensionalen Darstellung sonographischer Bilddaten in der Mund-, Kiefer- und Gesichtschirurgie