Virtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography
Open Access
- 13 March 2023
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (3) , e0282900
Abstract
Metal artifacts present a major challenge to computed tomography (CT) because they reduce the image quality in medical diagnosis and treatment. Several metal artifact reduction (MAR) methods have been proposed to address this issue in previous studies. This study aimed to synthesize a virtual monochromatic image for MAR in CT images using projection-based material decomposition (MD) algorithms. We developed a spectral micro-CT prototype system equipped with a photon-counting detector (PCD) and PCD-CT imaging simulator to assess the performances of different MAR methods. Two projection-based MD algorithms were implemented and evaluated for their MAR performances in CT images and compared with conventional sinogram inpainting MAR methods. Different parts of digital 4D-extended cardiac torso (XCAT) phantoms with metal implants were designed to simulate various real scenarios. A homemade metal artifact evaluation (MAE) phantom was used to evaluate the MAR performance in experiments. The simulated results of the XCAT phantom indicated that the projection-based virtual monochromatic CT (VMCT) images provided better image quality than the conventional MAR images without blurring the normal tissues at the position of the metal artifacts. Various quantitative indicators support this conclusion. Additionally, the experimental results of the MAE phantom reveal that projection-based VMCT images can avoid image distortion caused by metal artifacts, unlike conventional MAR methods. In regards to the projection-based VMCT images, the simulated and experimental results demonstrated that using the linear maximum likelihood estimators with an error correction look-up table algorithm yielded better MAR performance compared to that obtained using a polynomial algorithm. Furthermore, projection-based VMCT images can not only reduce metal artifacts effectively but also simultaneously prevents object blurring at the metal artifact position and image distortion of the metal implants. Hence, the CT image quality can be further improved to increase the abilities for both preoperative and postoperative assessment of metal implants.Keywords
Funding Information
- Chang Gung Memorial Hospital (CMRPD1K0442)
- National Science and Technology Council (No. 111-2221-E-182 -008 -MY3)
- Atomic Energy Council of Taiwan (No. AIE01030302)
- Chang Gung Memorial Hospital (BMRP14)
This publication has 45 references indexed in Scilit:
- Vision 20/20: Single photon counting x‐ray detectors in medical imagingMedical Physics, 2013
- Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Reduction of Metal Artifacts at CTRadioGraphics, 2013
- Estimator for photon counting energy selective x-ray imaging with multibin pulse height analysisMedical Physics, 2011
- Normalized metal artifact reduction (NMAR) in computed tomographyMedical Physics, 2010
- 4D XCAT phantom for multimodality imaging researchMedical Physics, 2010
- An experimental study on the noise properties of x-ray CT sinogram data in Radon spacePhysics in Medicine & Biology, 2008
- Artifacts in CT: Recognition and AvoidanceRadioGraphics, 2004
- X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prosthesesIEEE Transactions on Medical Imaging, 2000
- Analytic approximation of the log-signal and log-variance functions of x-ray imaging systems, with application to dual-energy imagingMedical Physics, 1991
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984