Hsin-Hon Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hsin-Hon Lin has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Lu-Han Lai
Department of Medical Imaging and Radiological Technology, Yuanpei University of Medical Technology, Hsinchu 30015, Taiwan
5 shared publications Keh-Shih Chuang
Department of Biomedical Engineering and Environmental Sciences, National Tsing-Hua University, Hsinchu, Taiwan
4 shared publicationsYu-Ching Ni
3 shared publications- Chia-Chun Lu
Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan
2 shared publications Chia-Hao Chang
2 shared publicationsChih-Chieh Chiang
2 shared publications
Latest Publications
- 13 March 2026
- Published by Elsevier in Radiation Measurements
- Vol. 194
Assessment of the system performance for a spectral micro-CT system based on the photon counting detector
- 13 March 2026
- Published by Elsevier in Radiation Measurements
- Vol. 194
Assessment of the system performance for a spectral micro-CT system based on the photon counting detector
- 16 June 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 237
Prompt gamma spectroscopy of metallic implants in proton therapy
- 16 June 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 237
Prompt gamma spectroscopy of metallic implants in proton therapy
- 14 January 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 217
Development of focusing multi-knife-edge camera for proton beam range verification: A Monte Carlo study
- 14 January 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 217
Development of focusing multi-knife-edge camera for proton beam range verification: A Monte Carlo study
- 2 August 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (9) , 4439-4454
Design and validation of a convolutional neural network for fast, model-free blood flow imaging with multiple exposure speckle imaging
Multiple exposure speckle imaging has demonstrated its improved accuracy compared to single exposure speckle imaging for relative quantitation of blood flow in vivo. However, the calculation of blood flow maps relies on a pixelwise non-linear fit of a multi-parametric model to the speckle contrasts. This approach has two major drawbacks. First, it is computer-intensive and prevents real time imaging and, second, the mathematical model is not universal and should in principle be adapted to the type of blood vessels. We evaluated a model-free machine learning approach based on a convolutional neural network as an alternative to the non-linear fit approach. A network was designed and trained with annotated speckle contrast data from microfluidic experiments. The neural network performances are then compared to the non-linear fit approach applied to in vitro and in vivo data. The study demonstrates the potential of convolutional networks to provide relative blood flow maps from multiple exposure speckle data in real time.
- 2 August 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (9) , 4439-4454
Design and validation of a convolutional neural network for fast, model-free blood flow imaging with multiple exposure speckle imaging
Multiple exposure speckle imaging has demonstrated its improved accuracy compared to single exposure speckle imaging for relative quantitation of blood flow in vivo. However, the calculation of blood flow maps relies on a pixelwise non-linear fit of a multi-parametric model to the speckle contrasts. This approach has two major drawbacks. First, it is computer-intensive and prevents real time imaging and, second, the mathematical model is not universal and should in principle be adapted to the type of blood vessels. We evaluated a model-free machine learning approach based on a convolutional neural network as an alternative to the non-linear fit approach. A network was designed and trained with annotated speckle contrast data from microfluidic experiments. The neural network performances are then compared to the non-linear fit approach applied to in vitro and in vivo data. The study demonstrates the potential of convolutional networks to provide relative blood flow maps from multiple exposure speckle data in real time.
- Open Access
- 13 March 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (3) , e0282900
Virtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography
Metal artifacts present a major challenge to computed tomography (CT) because they reduce the image quality in medical diagnosis and treatment. Several metal artifact reduction (MAR) methods have been proposed to address this issue in previous studies. This study aimed to synthesize a virtual monochromatic image for MAR in CT images using projection-based material decomposition (MD) algorithms. We developed a spectral micro-CT prototype system equipped with a photon-counting detector (PCD) and PCD-CT imaging simulator to assess the performances of different MAR methods. Two projection-based MD algorithms were implemented and evaluated for their MAR performances in CT images and compared with conventional sinogram inpainting MAR methods. Different parts of digital 4D-extended cardiac torso (XCAT) phantoms with metal implants were designed to simulate various real scenarios. A homemade metal artifact evaluation (MAE) phantom was used to evaluate the MAR performance in experiments. The simulated results of the XCAT phantom indicated that the projection-based virtual monochromatic CT (VMCT) images provided better image quality than the conventional MAR images without blurring the normal tissues at the position of the metal artifacts. Various quantitative indicators support this conclusion. Additionally, the experimental results of the MAE phantom reveal that projection-based VMCT images can avoid image distortion caused by metal artifacts, unlike conventional MAR methods. In regards to the projection-based VMCT images, the simulated and experimental results demonstrated that using the linear maximum likelihood estimators with an error correction look-up table algorithm yielded better MAR performance compared to that obtained using a polynomial algorithm. Furthermore, projection-based VMCT images can not only reduce metal artifacts effectively but also simultaneously prevents object blurring at the metal artifact position and image distortion of the metal implants. Hence, the CT image quality can be further improved to increase the abilities for both preoperative and postoperative assessment of metal implants.
- 13 March 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (3) , e0282900
Open AccessVirtual monochromatic imaging with projection-based material decomposition algorithm for metal artifacts reduction in photon-counting detector computed tomography
Metal artifacts present a major challenge to computed tomography (CT) because they reduce the image quality in medical diagnosis and treatment. Several metal artifact reduction (MAR) methods have been proposed to address this issue in previous studies. This study aimed to synthesize a virtual monochromatic image for MAR in CT images using projection-based material decomposition (MD) algorithms. We developed a spectral micro-CT prototype system equipped with a photon-counting detector (PCD) and PCD-CT imaging simulator to assess the performances of different MAR methods. Two projection-based MD algorithms were implemented and evaluated for their MAR performances in CT images and compared with conventional sinogram inpainting MAR methods. Different parts of digital 4D-extended cardiac torso (XCAT) phantoms with metal implants were designed to simulate various real scenarios. A homemade metal artifact evaluation (MAE) phantom was used to evaluate the MAR performance in experiments. The simulated results of the XCAT phantom indicated that the projection-based virtual monochromatic CT (VMCT) images provided better image quality than the conventional MAR images without blurring the normal tissues at the position of the metal artifacts. Various quantitative indicators support this conclusion. Additionally, the experimental results of the MAE phantom reveal that projection-based VMCT images can avoid image distortion caused by metal artifacts, unlike conventional MAR methods. In regards to the projection-based VMCT images, the simulated and experimental results demonstrated that using the linear maximum likelihood estimators with an error correction look-up table algorithm yielded better MAR performance compared to that obtained using a polynomial algorithm. Furthermore, projection-based VMCT images can not only reduce metal artifacts effectively but also simultaneously prevents object blurring at the metal artifact position and image distortion of the metal implants. Hence, the CT image quality can be further improved to increase the abilities for both preoperative and postoperative assessment of metal implants.
- Open Access
- 14 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10743
Radiation Dose Assessment of the Fog Lead Acrylic Shields during Coronary Angiography: A Phantom Study
This study aimed to evaluate the effects of fogging on the effectiveness of a lead glass shield in protecting an operator from radiation exposure during conventional coronary angiography (CAG). Optically stimulated luminescence dosimeters (OSLDs) were used to measure the effects of fogged lead glass shields (FLSs) and clear lead glass shields (CLSs) on the radiation doses of a cardiac catheterization surgeon. We simulated the scatter radiation incident on the operator with five angiographic projections with 10-s exposures. Experiments were conducted with a field of view of 25 cm, maximum of 100 cm between the X-ray tube and image intensifier, and 80 cm between the image intensifier and operator. Lead glass fogging had no significant effect at any angiographic projection. The average dose at the lens of the eye, thyroid glands, and gonads did not differ significantly between FLS and CLS. Although most surgeons view ceiling-suspended shields as hindrances during surgical procedures, the radiation dose at the operator’s eyes and thyroid glands increased by 13 and 10 times without the shield. The fogging of the shield is probably caused by post-surgery UV decontamination or detergents. An operator has no cause for concern regarding the radiation protection afforded by an FLS during CAG procedures.
- 14 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10743
Open AccessRadiation Dose Assessment of the Fog Lead Acrylic Shields during Coronary Angiography: A Phantom Study
This study aimed to evaluate the effects of fogging on the effectiveness of a lead glass shield in protecting an operator from radiation exposure during conventional coronary angiography (CAG). Optically stimulated luminescence dosimeters (OSLDs) were used to measure the effects of fogged lead glass shields (FLSs) and clear lead glass shields (CLSs) on the radiation doses of a cardiac catheterization surgeon. We simulated the scatter radiation incident on the operator with five angiographic projections with 10-s exposures. Experiments were conducted with a field of view of 25 cm, maximum of 100 cm between the X-ray tube and image intensifier, and 80 cm between the image intensifier and operator. Lead glass fogging had no significant effect at any angiographic projection. The average dose at the lens of the eye, thyroid glands, and gonads did not differ significantly between FLS and CLS. Although most surgeons view ceiling-suspended shields as hindrances during surgical procedures, the radiation dose at the operator’s eyes and thyroid glands increased by 13 and 10 times without the shield. The fogging of the shield is probably caused by post-surgery UV decontamination or detergents. An operator has no cause for concern regarding the radiation protection afforded by an FLS during CAG procedures.
- Open Access
- 6 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (7) , 3261
Assessment and Feasibility Study of Lemon Ripening Using X-ray Image of Information Visualization
Digital radiography (DR) is a mature technology and has been broadly used in medical diagnosis. Currently, it’s also used for fruit quality inspection in the market. This purpose of the study is to conduct non-destructive experiments for visual comparisons of digital radiography images, further construct visualized grayscale image analysis technology, and analyze the changes in lemon quality and ripening using quantitative statistical methods. The materials used for the experiments were three lemons of different ripening. A general medical X-ray DR system for was used in this study for 2D digital radiography. The medical X-ray DR images were created based on the Digital Imaging and Communications in Medicine (DICOM) standard. Photometric interpretation of monochrome was applied to create multi-layered grayscale images. Then quantitative analyses and comparisons were performed with image matrix structures and grayscale pixel values in the tissues using visualization techniques and statistical methods. After layer segmentation on the radiological images, the correlations between the lemon structures and tissue changes were assessed by using the Kruskal–Wallis test. The results showed that the p values for lemon, fiber, and pulp were all under 0.05, while the peel layer did not exhibit significant change. The pulp layer is the best region for statistical analyses to determine the lemon ripening. In conclusion, this study can provide a solid reference for future quality classification in the agricultural market. The research findings can be referenced for developing computing techniques applied to agricultural inspection, expanding the scope of application of the medical DR technology.
- 6 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (7) , 3261
Open AccessAssessment and Feasibility Study of Lemon Ripening Using X-ray Image of Information Visualization
Digital radiography (DR) is a mature technology and has been broadly used in medical diagnosis. Currently, it’s also used for fruit quality inspection in the market. This purpose of the study is to conduct non-destructive experiments for visual comparisons of digital radiography images, further construct visualized grayscale image analysis technology, and analyze the changes in lemon quality and ripening using quantitative statistical methods. The materials used for the experiments were three lemons of different ripening. A general medical X-ray DR system for was used in this study for 2D digital radiography. The medical X-ray DR images were created based on the Digital Imaging and Communications in Medicine (DICOM) standard. Photometric interpretation of monochrome was applied to create multi-layered grayscale images. Then quantitative analyses and comparisons were performed with image matrix structures and grayscale pixel values in the tissues using visualization techniques and statistical methods. After layer segmentation on the radiological images, the correlations between the lemon structures and tissue changes were assessed by using the Kruskal–Wallis test. The results showed that the p values for lemon, fiber, and pulp were all under 0.05, while the peel layer did not exhibit significant change. The pulp layer is the best region for statistical analyses to determine the lemon ripening. In conclusion, this study can provide a solid reference for future quality classification in the agricultural market. The research findings can be referenced for developing computing techniques applied to agricultural inspection, expanding the scope of application of the medical DR technology.
- Open Access
- 22 March 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (6) , 2815
Application of Visual Radiographic Analysis of Quality Grade of Table Eggs
Digital radiography is currently the main method of medical imaging diagnosis. It also has a wide range of applications across different fields. This study used radiation to conduct non-destructive visual imaging, and further established a quantitative analysis for visual gray-scale images to determine changes in the quality of eggs. Eggs of the same weight with three quality classes were chosen according to the egg labels available on the market. Furthermore, a general medical X-ray digital imaging system was used to apply two-dimensional digital radiography. A photometric interpretation of monochrome gray-scale imaging established by the Digital Imaging and Communications in Medicine (DICOM) standard was used to conduct a quantitative stratification analysis of the matrix data visualization, along with one-way analysis of variance (ANOVA) for quantitative statistics of the gray-scale values for the three structures, i.e., shell, air cell, and yolk. The statistical results showed that X-ray digital gray-scale images and a quantitative stratification analysis of the matrix data visualization results are less easily identified based on visual differences. In the quantitative statistical results of the one-way ANOVA gray-scale values, the whole-egg and in-egg quantitative matrix analysis both show p < 0.05. In the analysis of egg freshness, the quantitative statistics of the percentage of space occupied by the air cell in the eggs also showed p < 0.05. In addition, the results of the freshness of each egg were graded. The quality and freshness of the eggs can be quantitatively analyzed through radiographic imaging. The results of this study will provide a more scientific and quantitative reference for the quality and freshness of agricultural products in the future.
- 22 March 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (6) , 2815
Open AccessApplication of Visual Radiographic Analysis of Quality Grade of Table Eggs
Digital radiography is currently the main method of medical imaging diagnosis. It also has a wide range of applications across different fields. This study used radiation to conduct non-destructive visual imaging, and further established a quantitative analysis for visual gray-scale images to determine changes in the quality of eggs. Eggs of the same weight with three quality classes were chosen according to the egg labels available on the market. Furthermore, a general medical X-ray digital imaging system was used to apply two-dimensional digital radiography. A photometric interpretation of monochrome gray-scale imaging established by the Digital Imaging and Communications in Medicine (DICOM) standard was used to conduct a quantitative stratification analysis of the matrix data visualization, along with one-way analysis of variance (ANOVA) for quantitative statistics of the gray-scale values for the three structures, i.e., shell, air cell, and yolk. The statistical results showed that X-ray digital gray-scale images and a quantitative stratification analysis of the matrix data visualization results are less easily identified based on visual differences. In the quantitative statistical results of the one-way ANOVA gray-scale values, the whole-egg and in-egg quantitative matrix analysis both show p < 0.05. In the analysis of egg freshness, the quantitative statistics of the percentage of space occupied by the air cell in the eggs also showed p < 0.05. In addition, the results of the freshness of each egg were graded. The quality and freshness of the eggs can be quantitatively analyzed through radiographic imaging. The results of this study will provide a more scientific and quantitative reference for the quality and freshness of agricultural products in the future.
- Open Access
- 29 November 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (12) , 3884
Dosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer
This study aimed to compare different types of right breast cancer radiotherapy planning techniques and to estimate the whole-body effective doses and the critical organ absorbed doses. The three planning techniques are intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT; two methods) and hybrid 3D-CRT/IMRT (three-dimensional conformal radiotherapy/intensity-modulated radiotherapy). The VMAT technique includes two methods to deliver a dose: non-continuous partial arc and continuous partial arc. A thermoluminescent dosimeter (TLD) is placed in the RANDO phantom to estimate the organ absorbed dose. Each planning technique applies 50.4 Gy prescription dose and treats critical organs, including the lung and heart. Dose-volume histogram was used to show the planning target volume (V95%), homogeneity index (HI), conformity index (CI), and other optimized indices. The estimation of whole-body effective dose was based on the International Commission on Radiation Protection (ICRP) Publication 60 and 103. The results were as follows: Continuous partial arc and non-continuous partial arc showed the best CI and HI. The heart absorbed doses in the continuous partial arc and hybrid 3D-CRT/IMRT were 0.07 ± 0.01% and 0% (V5% and V10%, respectively). The mean dose of the heart was lowest in hybrid 3D-CRT/IMRT (1.47 Gy ± 0.02). The dose in the left contralateral lung (V5%) was lowest in continuous partial arc (0%). The right ipsilateral lung average dose and V20% are lowest in continuous partial arc. Hybrid 3D-CRT/IMRT has the lowest mean dose to contralateral breast (organs at risk). The whole-body effective doses for ICRP-60 and ICRP-103 were highest in continuous partial arc (2.01 Sv ± 0.23 and 2.89 Sv ± 0.15, respectively). In conclusion, the use of VMAT with continuous arc has a lower risk of radiation pneumonia, while hybrid 3D-CRT/IMRT attain lower secondary malignancy risk and cardiovascular complications.
- 29 November 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (12) , 3884
Open AccessDosimetric Comparison of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy and Hybrid Three-Dimensional Conformal Radiotherapy/Intensity-Modulated Radiotherapy Techniques for Right Breast Cancer
This study aimed to compare different types of right breast cancer radiotherapy planning techniques and to estimate the whole-body effective doses and the critical organ absorbed doses. The three planning techniques are intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT; two methods) and hybrid 3D-CRT/IMRT (three-dimensional conformal radiotherapy/intensity-modulated radiotherapy). The VMAT technique includes two methods to deliver a dose: non-continuous partial arc and continuous partial arc. A thermoluminescent dosimeter (TLD) is placed in the RANDO phantom to estimate the organ absorbed dose. Each planning technique applies 50.4 Gy prescription dose and treats critical organs, including the lung and heart. Dose-volume histogram was used to show the planning target volume (V95%), homogeneity index (HI), conformity index (CI), and other optimized indices. The estimation of whole-body effective dose was based on the International Commission on Radiation Protection (ICRP) Publication 60 and 103. The results were as follows: Continuous partial arc and non-continuous partial arc showed the best CI and HI. The heart absorbed doses in the continuous partial arc and hybrid 3D-CRT/IMRT were 0.07 ± 0.01% and 0% (V5% and V10%, respectively). The mean dose of the heart was lowest in hybrid 3D-CRT/IMRT (1.47 Gy ± 0.02). The dose in the left contralateral lung (V5%) was lowest in continuous partial arc (0%). The right ipsilateral lung average dose and V20% are lowest in continuous partial arc. Hybrid 3D-CRT/IMRT has the lowest mean dose to contralateral breast (organs at risk). The whole-body effective doses for ICRP-60 and ICRP-103 were highest in continuous partial arc (2.01 Sv ± 0.23 and 2.89 Sv ± 0.15, respectively). In conclusion, the use of VMAT with continuous arc has a lower risk of radiation pneumonia, while hybrid 3D-CRT/IMRT attain lower secondary malignancy risk and cardiovascular complications.