Intraocular liquids tamponade agents, such as perfluorocarbon liquids (PFCLs), semifluorinated alkanes (SFAs), silicone oils (SOs) and heavy silicone oils (HSOs), are a crucial intraoperative and/or postoperative tool in vitreoretinal surgery, in particular for the management of complex vitreoretinal diseases. However, their use is not without complications, which are potentially severe. Consequently, a growing interest has been devoted to the biocompatibility of these compounds and the adequacy of current regulations that should guarantee their safety. Obviously, an updated knowledge on research findings and potential risks associated to the use of intraocular liquid compounds is essential, not only for vitreoretinal surgeons, but also for any ophthalmologist involved in the management of patients receiving intraocular liquid tamponades. In light of this, the review provides a comprehensive characterisation of intraocular liquid tamponades, in terms of physical and chemical properties, current clinical use and possible complications. Moreover, this review focuses on the safety profile of these compounds, summarising the existing regulation and the available evidence on their biocompatibility.Keywords
This publication has 103 references indexed in Scilit:
- Visual loss after use of intraocular silicone oil associated with thinning of inner retinal layersActa Ophthalmologica, 2011
- Intraocular pressure changes following the use of silicone oil or Densiron® 68 as endotamponade in pars plana vitrectomyClinical Ophthalmology, 2010
- A Theoretical Model for Predicting Interfacial Relationships of Retinal TamponadesInvestigative Ophthalmology & Visual Science, 2010
- INCREASING THE EXTENSIONAL VISCOSITY OF SILICONE OIL REDUCES THE TENDENCY FOR EMULSIFICATIONRetina, 2010
- In vitro emulsification assessment of new silicone oilsBritish Journal of Ophthalmology, 2009
- Histopathological findings in an epimacular membrane after intraoperative use of perfluorocarbon liquidEye, 2009
- Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometryBiomechanics and Modeling in Mechanobiology, 2009
- Is silicone oil optic neuropathy caused by high intraocular pressure alone? A semi-biological modelBritish Journal of Ophthalmology, 2007
- Mechanical energy from intraocular instruments cause emulsification of silicone oilBritish Journal of Ophthalmology, 2006