ASAlberto Giacometti Schieroni

Alberto Giacometti Schieroni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alberto Giacometti Schieroni has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sustainable Conjugated Polymer Synthesis in OPV: A Case Study from Conventional to Flow and Microwave-Assisted Synthesis

    by Francesca Villafiorita-Monteleone, Benedetta Maria Squeo, Federico Turco, Antonella Caterina Boccia, Alberto Giacometti Schieroni, Daniele Piovani, Mariacecilia Pasini, Stefania Zappia

    Continuous flow synthesis and microwave-assisted synthesis represent two sustainable and efficient methods for polymer production aligned with green chemistry principles, compared to conventional polymer synthesis. Here we present a case study of poly(4,4-dioctyldithieno(3,2-b:2′,3′-d)silole)-2,6-diyl-alt-(2,1,3-benzothiadiazole)-4,7-diyl (PSBTBT), a low band-gap electron-donating polymer for organic photovoltaics (OPVs). The PSBTBT Stille cross-coupling polymerization conditions were optimized by comparing different synthetic methods: conventional, flow, and microwave. To assess the impact of the different synthetic methods, detailed molecular and spectroscopic characterization, highlighting both the differences and similarities within the methodologies, was performed with several techniques, such as GPC, UV-Vis, PL, and NMR.

  • Poly(biphenyl-piperidinium)/poly(biphenyl-trifluoroacetophenone) random and block copolymers enabling highly stable anion exchange membranes for water electrolysis

    by Tommaso Caielli, Alessandro Raffaele Ferrari, Diego Stucchi, Chiara Ferrara, Angela Caprì, Irene Gatto, Vincenzo Baglio, Alice Pancaldi, Adele Sassella, Stefania Zappia, et al.


  • Open Access

    Film Properties of Heparin Cross-Linked with Epichlorohydrin in Absence or Presence of Imidazole

    by Ivan Šimkovic, Filip Gucmann, Michal Hricovíni, Raniero Mendichi, Edmund Dobročka, Alberto Giacometti Schieroni, Daniele Piovani, Stefania Zappia, Miloš Hricovíni

    We cross-linked unfractionated heparin (H) using epichlorohydrin (E), in the absence or presence of imidazole (I), using various ratios of H, E, and I substances. The objectives and goals were to use the reaction for the preparation of medical materials suitable for blood sample applications. Nuclear magnetic resonance indicated the involvement of an H-end sequence [H-(1→4)-β-D-GlcA-(1→3)-β-D-Gal-(1→3)-β-D-Gal-(1→4)-β-D-Xyl-α-Ser] in the linkage with the 2-hydroxypropyl bridge. The yields of the individual experiments were found to increase in the following ratios: 1H/1E/3I (24%) < 1H/1E/2I (32%) < 1H/3E (42%) < 1H/1E/1I (46%) < 1H/2E (64%) < 1H/1E (77%). According to size-exclusion chromatography with multiple-angle light scattering (SEC-MALS) analysis, the mass at the peak increased in the following order: H (9292 g/mol) < 1H/1E (9294 g/mol) < 1H/2E (9326 g/mol) < 1H/3E (9708 g/mol) < 1H/1E/2I (11,212 g/mol) < 1H/1E/3I (12,301 g/mol) < 1H/1E/1I (13,800 g/mol) and in the reverse order with the increase in amount of epichlorohydrin and imidazole, i.e., 1H/1E > 1H/2E > 1H/3E and 1H/1E/1I > 1H/1E/2I > 1H/1E/3I. X-ray diffraction revealed that all prepared films were amorphous. An evaluation of the surface morphology using atomic force microscopy (AFM) confirmed a relatively low films roughness (~0.9–3.6 nm). The surface reduced elastic modulus, determined by the PeakForce quantitative nanomechanical mapping (PF-QNM) technique, was found to increase by up to ~63% for films cross-linked with E in the absence of I when compared with the results for the H substrate. A negligible change in modulus was, however, observed for films cross-linked in the presence of I, or was even reduced by ~15% (1H/1E/3I) compared to that for the H substrate. This could be explained by the parallel cross-linking of H only with E within its serine end unit and in competition with only one nitrogen of I. According to the highest yield (77%) of 1H/1E, the preferred product is the following: H-(1→4)-β-D-GlcA-(1→3)-β-D-Gal-(1→3)-β-D-Gal-(1→4)-β-D-Xyl-α-Ser-CH2-CH(OH)-CH2-OH. For the 1H/1E/1I (46% yield), 1H/1E/2I (32%), and 1H/1E/3I (24%) products, the cross-linked motif was the same, and the difference represented the surplus amount of the imidazolium cation ionically bound to the heparin anionic groups.

  • Open Access

    Click-Chemistry Cross-Linking of Hyaluronan Graft Copolymers

    by Mario Saletti, Marco Paolino, Lavinia Ballerini, Germano Giuliani, Gemma Leone, Stefania Lamponi, Marco Andreassi, Claudia Bonechi, Alessandro Donati, Daniele Piovani, et al.

    An easy and viable crosslinking procedure by click-chemistry (click-crosslinking) of hyaluronic acid (HA) was developed. In particular, the clickable propargyl groups of hyaluronane-based HA-FA-Pg graft copolymers showing low and medium molecular weight values were exploited in crosslinking by click-chemistry by using a hexa(ethylene glycol) spacer. The resulting HA-FA-HEG-CL materials showed an apparent lack of in vitro cytotoxic effects, tuneable water affinity, and rheological properties according to the crosslinking degree that suggests their applicability in different biomedical fields.


  • Biocompatibility of intraocular liquid tamponade agents: an update

    by Mario R. Romano, Mariantonia Ferrara, Irene Nepita, Jana D’aMato Tothova, Alberto Giacometti Schieroni, Daniela Reami, Raniero Mendichi, Libero Liggieri, Rodolfo Repetto

    Intraocular liquids tamponade agents, such as perfluorocarbon liquids (PFCLs), semifluorinated alkanes (SFAs), silicone oils (SOs) and heavy silicone oils (HSOs), are a crucial intraoperative and/or postoperative tool in vitreoretinal surgery, in particular for the management of complex vitreoretinal diseases. However, their use is not without complications, which are potentially severe. Consequently, a growing interest has been devoted to the biocompatibility of these compounds and the adequacy of current regulations that should guarantee their safety. Obviously, an updated knowledge on research findings and potential risks associated to the use of intraocular liquid compounds is essential, not only for vitreoretinal surgeons, but also for any ophthalmologist involved in the management of patients receiving intraocular liquid tamponades. In light of this, the review provides a comprehensive characterisation of intraocular liquid tamponades, in terms of physical and chemical properties, current clinical use and possible complications. Moreover, this review focuses on the safety profile of these compounds, summarising the existing regulation and the available evidence on their biocompatibility.


  • Molar Mass Distribution of a Polymer-Drug Conjugate Containing the Antitumor Drug Paclitaxel by Size Exclusion Chromatography and Universal Calibration

    by R. Mendichi, V. Rizzo, M. Gigli, G. Razzano, F. Angelucci, A. Giacometti Schieroni

    The development of a Size Exclusion Chromatography (SEC) method for the characterization of the polymer-drug conjugate PNU 166945 is presented. PNU 166945 is a conjugate between poly[N-(2-hydroxypropyl) methacrylamide)] and the antitumor drug paclitaxel. This study follows a previous paper on a similar polymer conjugate, FCE 28068, containing the same polymeric carrier and the antitumor drug doxorubicin. The aim was an accurate and reproducible, yet relatively simple and rapid method for the routine quality control of production batches. Thirteen PNU 166945 narrow fractions were separated, by semi-preparative SEC, and characterized by on-line SEC-Viscometry and off-line Light Scattering. The fractions allowed us to verify that PNU 166945 follows the universal calibration constructed with PEO/PEG narrow standards. So a conventional SEC method that utilizes just a refractive index detector and universal calibration with commercial narrow standards was found suitable. The study also reports data on accuracy and reproducibility of the SEC measurement.