Modeling Photon Counting Detector Anode Street Impact on Detector Energy Response
- 31 July 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 476-484
Abstract
Accurate modeling of a photon counting detector is essential for detector design and performance evaluation, system-level performance investigation, and image reconstruction. This modeling is complicated because various factors involve and couple together, including X-ray interactions, fluorescence X-rays escaping and absorption, primary charge cloud distribution, charge diffusion and interactions (repulsion), and charge trapping. In this paper, we adapted a comprehensive detector modeling approach, which incorporates all these relevant factors into account. This approached allowed us to evaluate the impact of different physical effects on the detector energy response. In particular, we evaluated the impact of anode street impact on the detector energy response. We found the conductivity difference between the anode street surface and the bulk region within the sensor volume could significantly affect the detector energy response including reducing peak events and increasing the low-energy tail events. As compared to without considering the anode street conductivity difference, the detection efficiency at 60 keV could be reduced by 5-15% (40 μm street size), and 12-33% (70 μm street size) when the threshold was varied from 45-57 keV.Keywords
This publication has 25 references indexed in Scilit:
- Experimental comparison of empirical material decomposition methods for spectral CTPhysics in Medicine & Biology, 2015
- Computational modelling of pixelated CdZnTe detectors for x- and γ- ray imaging applicationsJournal of Instrumentation, 2012
- Monte Carlo investigation of charge‐transport effects on energy resolution and detection efficiency of pixelated CZT detectors for SPECT/PET applicationsMedical Physics, 2010
- Development of a simplified simulation model for performance characterization of a pixellated CdZnTe multimodality imaging systemPhysics in Medicine & Biology, 2008
- Effect of surfaces on the performance of CdZnTe detectors2001
- Effects of charge sharing in 3-D position sensitive CdZnTe gamma-ray spectrometersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000
- Method for mapping charge pulses in semiconductor radiation detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- Penetration and energy-loss theory of electrons in solid targetsJournal of Physics D: Applied Physics, 1972
- Currents to Conductors Induced by a Moving Point ChargeJournal of Applied Physics, 1938
- Zum Mechanismus des lichtelektrischen Prim rstromes in isolierenden KristallenThe European Physical Journal A, 1932