Go Kawata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Go Kawata has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Brent Budden
Canon Medical Research, USA
1 shared publicationHiroaki Miyazaki
Canon Medical Systems Corporation
1 shared publicationHiroaki Nakai
Canon Medical Systems Corporation
1 shared publicationHirotaka Araki
CANON Inc
1 shared publicationJ. Yoshida
Toshiba Corporate Research and Development Center, Kawasaki, Japan
1 shared publicationJumpei Shirono
CANON Inc
1 shared publication
Latest Publications
- 22 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (8) , 867-875
Analyze Methodology of ToF Spectrum on Cherenkov and Scintillation Emission in BGO Scintillator
A time-of-flight (ToF) spectrum model has been developed to quantitatively understand the emission sequences in realistic scintillation detectors. This model is used to carefully investigate the Cherenkov and scintillation photon emission processes. To construct this model, we initially identified several primary physical processes occurring within scintillators and selected those that significantly contribute to the spectrum. The characteristics of each process were statistically incorporated into the model. Importantly, the model also takes into account the variance in the interaction point between the incident gamma photon and the electron, which serves as a contributing factor. To confirm the model’s validity, an experiment was conducted. A pair of 20 mm-long bismuth germanate oxide detectors, paired with a silicon photomultiplier, used for this purpose. Experimental results provided the number of scintillation photons and the scintillation decay time constants. The time constant for Cherenkov emission was derived from the existing literature, and approximately one Cherenkov photon was used to fit the ToF spectrum obtained by the experiment. The model successfully reproduced the experimental ToF spectra with validity using the parameter values obtained in the experiment. However, the estimated number of scintillation photons in our experiment was about half of the yield number reported in literatures, while the number of Cherenkov photons utilized in the validation process was in line with those reported by other groups. Our results suggest that a combined analysis of the phenomenological model that accepts the behavior of the real system and particle-based Monte-Carlo simulation that treats the ideal system deductively is a meaningful approach for detector development based on an accurate understanding of the real system.
- 22 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 8 (8) , 867-875
Analyze Methodology of ToF Spectrum on Cherenkov and Scintillation Emission in BGO Scintillator
A time-of-flight (ToF) spectrum model has been developed to quantitatively understand the emission sequences in realistic scintillation detectors. This model is used to carefully investigate the Cherenkov and scintillation photon emission processes. To construct this model, we initially identified several primary physical processes occurring within scintillators and selected those that significantly contribute to the spectrum. The characteristics of each process were statistically incorporated into the model. Importantly, the model also takes into account the variance in the interaction point between the incident gamma photon and the electron, which serves as a contributing factor. To confirm the model’s validity, an experiment was conducted. A pair of 20 mm-long bismuth germanate oxide detectors, paired with a silicon photomultiplier, used for this purpose. Experimental results provided the number of scintillation photons and the scintillation decay time constants. The time constant for Cherenkov emission was derived from the existing literature, and approximately one Cherenkov photon was used to fit the ToF spectrum obtained by the experiment. The model successfully reproduced the experimental ToF spectra with validity using the parameter values obtained in the experiment. However, the estimated number of scintillation photons in our experiment was about half of the yield number reported in literatures, while the number of Cherenkov photons utilized in the validation process was in line with those reported by other groups. Our results suggest that a combined analysis of the phenomenological model that accepts the behavior of the real system and particle-based Monte-Carlo simulation that treats the ideal system deductively is a meaningful approach for detector development based on an accurate understanding of the real system.
- 31 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 476-484
Modeling Photon Counting Detector Anode Street Impact on Detector Energy Response
Accurate modeling of a photon counting detector is essential for detector design and performance evaluation, system-level performance investigation, and image reconstruction. This modeling is complicated because various factors involve and couple together, including X-ray interactions, fluorescence X-rays escaping and absorption, primary charge cloud distribution, charge diffusion and interactions (repulsion), and charge trapping. In this paper, we adapted a comprehensive detector modeling approach, which incorporates all these relevant factors into account. This approached allowed us to evaluate the impact of different physical effects on the detector energy response. In particular, we evaluated the impact of anode street impact on the detector energy response. We found the conductivity difference between the anode street surface and the bulk region within the sensor volume could significantly affect the detector energy response including reducing peak events and increasing the low-energy tail events. As compared to without considering the anode street conductivity difference, the detection efficiency at 60 keV could be reduced by 5-15% (40 μm street size), and 12-33% (70 μm street size) when the threshold was varied from 45-57 keV.
- 31 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (4) , 476-484
Modeling Photon Counting Detector Anode Street Impact on Detector Energy Response
Accurate modeling of a photon counting detector is essential for detector design and performance evaluation, system-level performance investigation, and image reconstruction. This modeling is complicated because various factors involve and couple together, including X-ray interactions, fluorescence X-rays escaping and absorption, primary charge cloud distribution, charge diffusion and interactions (repulsion), and charge trapping. In this paper, we adapted a comprehensive detector modeling approach, which incorporates all these relevant factors into account. This approached allowed us to evaluate the impact of different physical effects on the detector energy response. In particular, we evaluated the impact of anode street impact on the detector energy response. We found the conductivity difference between the anode street surface and the bulk region within the sensor volume could significantly affect the detector energy response including reducing peak events and increasing the low-energy tail events. As compared to without considering the anode street conductivity difference, the detection efficiency at 60 keV could be reduced by 5-15% (40 μm street size), and 12-33% (70 μm street size) when the threshold was varied from 45-57 keV.
- 24 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 65 (6) , 2525-2530
Avalanche-Area Dependence of Gain in Passive-Quenched Single-Photon Avalanche Diodes by Multiple-Photon Injection
It is widely believed that the single-photon gain (SPG) of passive-quenched single-photon avalanche diodes (PQ-SPADs) is given by the product of the junction capacitance (Cd) and the overvoltage (Vov) applied to the SPAD and that this gain remains constant even under multiple-photon injection. In this paper, we show that these are not always true. We found that the SPG of PQ-SPADs increases with increasing irradiation power of a picosecond pulse laser. This result is understood by considering that the avalanche area generated by a single-avalanche trigger is smaller than the active area of the diode, and that multiple-photon injection induces multiple-avalanche triggers in the depletion layer resulting in a variation in the avalanche area within the junction. Numerical transient simulation using a 1-D avalanche diode model coupled with 2-D junction capacitance reveals that the SPG increases from CdVov to 2Cd Vov as the ratio of the avalanche area to diode active area increases.
- 24 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 65 (6) , 2525-2530
Avalanche-Area Dependence of Gain in Passive-Quenched Single-Photon Avalanche Diodes by Multiple-Photon Injection
It is widely believed that the single-photon gain (SPG) of passive-quenched single-photon avalanche diodes (PQ-SPADs) is given by the product of the junction capacitance (Cd) and the overvoltage (Vov) applied to the SPAD and that this gain remains constant even under multiple-photon injection. In this paper, we show that these are not always true. We found that the SPG of PQ-SPADs increases with increasing irradiation power of a picosecond pulse laser. This result is understood by considering that the avalanche area generated by a single-avalanche trigger is smaller than the active area of the diode, and that multiple-photon injection induces multiple-avalanche triggers in the depletion layer resulting in a variation in the avalanche area within the junction. Numerical transient simulation using a 1-D avalanche diode model coupled with 2-D junction capacitance reveals that the SPG increases from CdVov to 2Cd Vov as the ratio of the avalanche area to diode active area increases.
- 20 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 64 (00189499) , 1
Probability Distribution of After-pulsing in Passive-quenched Single-photon Avalanche Diodes
The resolution and accuracy of the number of photons detected by a silicon photomultiplier (SiPM) are limited by the excess noise, which consists mainly of after pulsing and optical crosstalk. Since these excess noises are correlated with each other, it is challenging to determine the after pulsing and the optical crosstalk probabilities independently of the output signal of the SiPM. Here we examine the dynamic response of passive-quenched single-photon avalanche diodes to clarify the characteristics of the after pulsing. Optical crosstalk is not present in the output signals of single-photon avalanche diodes; therefore, we can obtain the after-pulsing probability directly from the experimental results. We derive an analytical expression for the probability density function of after-pulse timing and analyze the experimental data based on this expression. We confirm that two types of trap levels with emission lifetimes on the order of 10 and 100 ns are responsible for the after pulsing in our devices. The dependence of the after-pulsing probability on the device recovery time is also well explained by our model.
- 20 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 64 (00189499) , 1
Probability Distribution of After-pulsing in Passive-quenched Single-photon Avalanche Diodes
The resolution and accuracy of the number of photons detected by a silicon photomultiplier (SiPM) are limited by the excess noise, which consists mainly of after pulsing and optical crosstalk. Since these excess noises are correlated with each other, it is challenging to determine the after pulsing and the optical crosstalk probabilities independently of the output signal of the SiPM. Here we examine the dynamic response of passive-quenched single-photon avalanche diodes to clarify the characteristics of the after pulsing. Optical crosstalk is not present in the output signals of single-photon avalanche diodes; therefore, we can obtain the after-pulsing probability directly from the experimental results. We derive an analytical expression for the probability density function of after-pulse timing and analyze the experimental data based on this expression. We confirm that two types of trap levels with emission lifetimes on the order of 10 and 100 ns are responsible for the after pulsing in our devices. The dependence of the after-pulsing probability on the device recovery time is also well explained by our model.