RARE two‐point Dixon with dual bandwidths
Open Access
- 25 April 2020
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2456-2468
Abstract
Purpose: To investigate the impact of dual readout bandwidths (dBW) in a dual echo fat/water acquisition and describe a dBW‐rapid acquisition relaxation enhanced, or turbo spin echo sequence where the concept is used to improve SNR by removing dead times between refocusing pulses and avoiding redundant Chemical‐shift encoded.Methods: Cramér‐Rao bounds and Monte Carlo simulations were used to investigate a two‐point fat/water model where the difference in bandwidths is incorporated. In vivo images were acquired at 1.5 and 3 T with the dBW‐rapid acquisition relaxation enhanced, or turbo spin echo sequence. Typical bandwidth ratios were 1:2. SNR was compared with a single bandwidth sequence under identical scan parameters at 3T.Results: Monte Carlo simulations and Cramér‐Rao analysis demonstrate that number of signal averages can be improved with dual bandwidths compared to conventional single bandwidth acquisitions. The dBW‐rapid acquisition relaxation enhanced, or turbo spin echo sequence can acquire images with high readout resolutions with well‐conditioned sampling. An SNR improvement of 52% was measured, in line with the theoretical gain of 54%.Conclusions: The proposed dBW‐rapid acquisition relaxation enhanced, or turbo spin echo sequence is a highly SNR‐efficient two‐point rapid acquisition relaxation enhanced, or turbo spin echo sequence without dead times, and can acquire images at higher resolutions than current vendor‐supplied alternatives.Keywords
This publication has 27 references indexed in Scilit:
- Bone Marrow Metastases: T2-weighted Dixon Spin-Echo Fat Images Can Replace T1-weighted Spin-Echo ImagesRadiology, 2018
- Detection of vertebral metastases: a comparison between the modified Dixon turbo spin echo T 2 weighted MRI and conventional T 1 weighted MRI: a preliminary study in a tertiary centreBritish Journal of Radiology, 2018
- Measurement of fat content in vertebral marrow using a modified dixon sequence to differentiate benign from malignant processesJournal of Magnetic Resonance Imaging, 2016
- Fast dixon whole‐body MRI for detecting distant cancer metastasis: a preliminary clinical studyJournal of Magnetic Resonance Imaging, 2011
- Two‐point dixon method with flexible echo timesMagnetic Resonance in Medicine, 2010
- Dual‐echo Dixon imaging with flexible choice of echo timesMagnetic Resonance in Medicine, 2010
- Two‐point water‐fat imaging with partially‐opposed‐phase (POP) acquisition: An asymmetric Dixon methodMagnetic Resonance in Medicine, 2006
- Nonspecificity of short inversion time inversion recovery (STIR) as a technique of fat suppression: pitfalls in image interpretation.American Journal of Roentgenology, 1996
- RARE imaging: A fast imaging method for clinical MRMagnetic Resonance in Medicine, 1986
- Simple proton spectroscopic imaging.Radiology, 1984