Enhanced PET resolution by combining pinhole collimation and coincidence detection
- 29 September 2015
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (20) , 7969-7984
Abstract
Spatial resolution of clinical PET scanners is limited by detector design and photon non-colinearity. Although dedicated small animal PET scanners using specialized high-resolution detectors have been developed, enhancing the spatial resolution of clinical PET scanners is of interest as a more available alternative. Multi-pinhole 511 keV SPECT is capable of high spatial resolution but requires heavily shielded collimators to avoid significant background counts. A practical approach with clinical PET detectors is to combine multi-pinhole collimation with coincidence detection. In this new hybrid modality, there are three locations associated with each event, namely those of the two detected photons and the pinhole aperture. These three locations over-determine the line of response and provide redundant information that is superior to coincidence detection or pinhole collimation alone. Multi-pinhole collimation provides high resolution and avoids non-colinearity error but is subject to collimator penetration and artifacts from overlapping projections. However the coincidence information, though at lower resolution, is valuable for determining whether the photon passed near a pinhole within the cone acceptance angle and for identifying through which pinhole the photon passed. This information allows most photons penetrating through the collimator to be rejected and avoids overlapping projections. With much improved event rejection, a collimator with minimal shielding may be used, and a lightweight add-on collimator for high resolution imaging is feasible for use with a clinical PET scanner. Monte Carlo simulations were performed of a 18 F hot rods phantom and a 54-pinhole unfocused whole-body mouse collimator with a clinical PET scanner. Based on coincidence information and pinhole geometry, events were accepted or rejected, and pinhole-specific crystal-map projections were generated. Tomographic images then were reconstructed using a conventional pinhole SPECT algorithm. Hot rods of 1.4 mm diameter were resolved easily in a simulated phantom. System sensitivity was 0.09% for a simulated 70-mm line source corresponding to the NEMA NU-4 mouse phantom. Higher resolution is expected with further optimization of pinhole design, and higher sensitivity is expected with a focused and denser pinhole configuration. The simulations demonstrate high spatial resolution and feasibility of small animal imaging with an add-on multi-pinhole collimator for a clinical PET scanner. Further work is needed to develop geometric calibration and quantitative data corrections and, eventually, to construct a prototype device and produce images with physical phantoms.Keywords
This publication has 38 references indexed in Scilit:
- NEMA NU 4-2008 Performance Measurements of Two Commercial Small-Animal PET Scanners: ClearPET and rPET-1IEEE Transactions on Nuclear Science, 2010
- Small-Animal Molecular Imaging MethodsJournal of Nuclear Medicine, 2010
- High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applicationsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT–CT scannersPhysics in Medicine & Biology, 2008
- Simulation of a pinhole-collimator insert for small animal PET using GATE2007
- Pinhole PET (pPET): a Multi-Pinhole Collimator Insert for Small Animal SPECT Imaging on PET cameras2006
- A Sensitivity Model for Multi-Pinhole SPECT2006
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Mathematical Removal of Positron Range Blurring in High Resolution TomographyIEEE Transactions on Nuclear Science, 1986
- RADIOISOTOPE CAMERAS1967