Preclinical Evaluation of an Everolimus-Eluting Bioresorbable Vascular Scaffold Via a Long-Term Rabbit Iliac Artery Model
- 7 March 2023
- journal article
- research article
- Published by Springer Nature in Tissue Engineering and Regenerative Medicine
- Vol. 20 (2) , 239-249
Abstract
Background: Biodegradable poly (l-lactic acid) (PLLA), a bio safe polymer with a large elastic modulus, is widely used in biodegradable medical devices. However, because of its poor mechanical properties, a PLLA strut must be made twice as thick as a metal strut for adequate blood vessel support. Therefore, the mechanical properties of a drug-eluting metal-based stents (MBS) and a bioresorbable vascular scaffolds (BVS) were evaluated and their safety and efficacy were examined via a long-term rabbit iliac artery model. Methods: The surface morphologies of the MBSs and BVSs were investigated via optical and scanning electron microscopy. An everolimus-eluting (EE) BVS or an EE-MBS was implanted into rabbit iliac arteries at a 1.1:1 stent-to-artery ratio. Twelve months afterward, stented iliac arteries from each group were analyzed via X-ray angiography, optical coherence tomography (OCT), and histopathologic evaluation. Results: Surface morphology analysis of the EE coating on the MBS confirmed that it was uniform and very thin (4.7 μm). Comparison of the mechanical properties of the EE-MBS and EE-BVS showed that the latter outperformed the former in all aspects (radial force (2.75 vs. 0.162 N/mm), foreshortening (0.24% vs. 1.9%), flexibility (0.52 vs. 0.19 N), and recoil (3.2% vs. 6.3%). At all time points, the percent area restenosis was increased in the EE-BVS group compared to the EE-MBS group. The OCT and histopathological analyses indicate no significant changes in strut thickness. Conclusion: BVSs with thinner struts and shorter resorption times should be developed. A comparable long-term safety/efficacy evaluation after complete absorption of BVSs should be conducted.Keywords
Funding Information
- Korea Medical Device Development Fund (1711138916, KMDF_PR_20200901_0280, 1711137864, KMDF_PR_20200901_0005)
- Ministry of Education, Science and Technology (NRF-2020R1I1A3A04036675)
This publication has 27 references indexed in Scilit:
- Coronary stents: historical development, current status and future directionsBritish Medical Bulletin, 2013
- Tissue response to poly(l-lactic acid)-based blend with phospholipid polymer for biodegradable cardiovascular stentsBiomaterials, 2011
- Very Late Stent Thrombosis due to Neointimal Rupture After Paclitaxel-Eluting Stent ImplantationKorean Circulation Journal, 2011
- The biocompatibility of rapidly degrading polymeric stents in porcine carotid arteriesBiomaterials, 2010
- Drug-Eluting Stents in Preclinical StudiesCirculation: Cardiovascular Interventions, 2008
- Universal Definition of Myocardial InfarctionCirculation, 2007
- Pathology of Drug-Eluting Stents in HumansJACC, 2006
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJACC, 1992
- Pathobiology of acute myocardial ischemia: Metabolic, functional and ultrastructural studiesThe American Journal of Cardiology, 1983
- TRANSLUMINAL DILATATION OF CORONARY-ARTERY STENOSISThe Lancet, 1978