  • Dual-Drug Stent with Sirolimus and WKYMVm Promotes Endothelialization and Limits Hyperplasia

    by Yu Jeong Jin, Dae Sung Park, Myung Ho Jeong, Doo Sun Sim, Mi Hyang Na, Chan Woo Kim, Hae Jin Kee, Young Joon Hong, Kyung Hoon Cho, Dae Young Hyun, et al.

    Background: Conventional drug-eluting stents suppress neointimal hyperplasia but delay re-endothelialization, raising long-term safety concerns. This study developed and evaluated a sirolimus–WKYMVm eluting stent (S-WES) to simultaneously promote re-endothelialization and suppress neointimal hyperplasia. Methods: Sirolimus-eluting stents (SES), WKYMVm-eluting stents (WES), and S-WES were fabricated using electrospray. Surface morphology was characterized via scanning electron microscopy (SEM), and in vitro drug-release kinetics were determined using high-performance liquid chromatography. Biological efficacy was assessed using human umbilical vein endothelial cell (HUVEC) and smooth muscle cell (SMC) assays. In vivo performance was evaluated over 4 weeks, followed by optical coherence tomography (OCT) and histopathological analysis. Results: SEM analysis showed that S-WES had a uniform, crack-free polymer coating. Each stent was consistently loaded with sirolimus (105.15 ± 25.54 μg) and WKYMVm (1.07 ± 0.18 μg), yielding a dual drug-release profile. WKYMVm was almost completely released within 7 days, whereas sirolimus showed sustained release (day 1: 22.43 ± 5.32%, day 28: 94.38 ± 4.11%). In vitro assays showed that sirolimus suppressed SMC migration and HUVEC proliferation, while WKYMVm significantly enhanced HUVEC proliferation. In vivo OCT revealed reduced neointimal hyperplasia in the S-WES group (29.64 ± 8.66 μm2) compared with SES (34.65 ± 7.50 μm2; p = 0.041). Histopathology and immunohistology showed reduced stenosis ratio (28.39 ± 6.84%), decreased α-SMA expression, and increased VE-cadherin, CD31-positive endothelial coverage in the S-WES group. Conclusion: The sirolimus–WKYMVm dual-drug stent enhances re-endothelialization and inhibits neointimal hyperplasia, thereby offering a promising strategy for improving the efficacy and long-term safety of cardiovascular stents.

  • Open Access

    The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model

    by Seok Oh, Ju Han Kim, Saleem Ahmad, Yu Jeong Jin, Mi Hyang Na, Munki Kim, Jeong Ha Kim, Dae Sung Park, Dae Young Hyun, Kyung Hoon Cho, et al.

    Oh S, et al. Korean Circ J. 2025 Jan;55(1):50-64. https://doi.org/10.4070/kcj.2024.0171


  • Efficacy and Safety Evaluation of Tacrolimus-Eluting Stent in a Porcine Coronary Artery Model

    by Dae Sung Park, Mi Hyang Na, Myung Ho Jeong, Doo Sun Sim, Yu Jeong Jin, Hae Jin Kee, Mun Ki Kim, Young Joon Hong, Kyung Hoon Cho, Dae Young Hyun, et al.

    Background: A drug-eluting stent (DES) is a highly beneficial medical device used to widen or unblock narrowed blood vessels. However, the drugs released by the implantation of DES may hinder the re-endothelialization process, increasing the risk of late thrombosis. We have developed a tacrolimus-eluting stent (TES) that as acts as a potent antiproliferative and immunosuppressive agent, enhancing endothelial regeneration. In addition, we assessed the safety and efficacy of TES through both in vitro and in vivo tests. Methods: Tacrolimus and Poly(lactic-co-glycolic acid) (PLGA) were applied to the metal stent using electrospinning equipment. The surface morphology of the stent was examined before and after coating using a scanning electron microscope (SEM) and energy dispersive X-rays (EDX). The drug release test was conducted through high-performance liquid chromatography (HPLC). Cell proliferation and migration assays were performed using smooth muscle cells (SMC). The stent was then inserted into the porcine coronary artery and monitored for a duration of 4 weeks. Results: SEM analysis confirmed that the coating surface was uniform. Furthermore, EDX analysis showed that the surface was coated with both polymer and drug components. The HPCL analysis of TCL at a wavelength of 215 nm revealed that the drug was continuously released over a period of 4 weeks. Smooth muscle cell migration was significantly decreased in the tacrolimus group (54.1% ± 11.90%) compared to the non-treated group (90.1% ± 4.86%). In animal experiments, the stenosis rate was significantly reduced in the TES group (29.6% ± 7.93%) compared to the bare metal stent group (41.3% ± 10.18%). Additionally, the fibrin score was found to be lower in the TES group compared to the group treated with a sirolimus-eluting stent (SES). Conclusion: Similar to SES, TES reduces neointimal proliferation in a porcine coronary artery model, specifically decreasing the fibrins score. Therefore, tacrolimus could be considered a promising drug for reducing restenosis and thrombosis.


  • Open Access

    First-in-Human Evaluation of a Polymer-Free Everolimus-Eluting Stent Using a Titanium Dioxide Film

    by Doo Sun Sim, Kyung Hoon Cho, Dae Young Hyun, Dae Sung Park, Jun-Kyu Park, Dae-Heung Byeon, Won-Il Jo, Sang-Wook Kim, Joon Ho Ahn, Seung Hun Lee, et al.

    Sim DS, et al. J Korean Med Sci. 2024 Jul;39:e234. https://doi.org/10.3346/jkms.2024.39.e234


  • Preliminary Investigation on Efficacy and Safety of Substance P-Coated Stent for Promoting Re-Endothelialization: A Porcine Coronary Artery Restenosis Model

    by Dae Sung Park, Seok Oh, Yu Jeong Jin, Mi Hyang Na, Munki Kim, Jeong Ha Kim, Dae Young Hyun, Kyung Hoon Cho, Young Joon Hong, Ju Han Kim, et al.

    Background: Current polymer-based drug-eluting stents (DESs) have fundamental issues about inflammation and delayed re-endothelializaton of the vessel wall. Substance-P (SP), which plays an important role in inflammation and endothelial cells, has not yet been applied to coronary stents. Therefore, this study compares poly lactic-co-glycolic acid (PLGA)-based everolimus-eluting stents (PLGA-EESs) versus 2-methacryloyloxyethyl phosphorylcholine (MPC)-based SP-eluting stents (MPC-SPs) in in-vitro and in-vivo models. Methods: The morphology of the stent surface and peptide/drug release kinetics from stents were evaluated. The in-vitro proliferative effect of SP released from MPC-SP is evaluated using human umbilical vein endothelial cell. Finally, the safety and efficacy of the stent are evaluated after inserting it into a pig's coronary artery. Results: Similar to PLGA-EES, MPC-SP had a uniform surface morphology with very thin coating layer thickness (2.074 μm). MPC-SP showed sustained drug release of SP for over 2 weeks. Endothelial cell proliferation was significantly increased in groups treated with SP (n = 3) compared with the control (n = 3) and those with everolimus (n = 3) (SP: 118.9 ± 7.61% vs. everolimus: 64.3 ± 12.37% vs. the control: 100 ± 6.64%, p < 0.05). In the animal study, the percent stenosis was higher in MPC-SP group (n = 7) compared to PLGA-EES group (n = 7) (MPC-SP: 28.6 ± 10.7% vs. PLGA-EES: 16.7 ± 6.3%, p < 0.05). MPC-SP group showed, however, lower inflammation (MPC-SP: 0.3 ± 0.26 vs. PLGA-EES: 1.2 ± 0.48, p < 0.05) and fibrin deposition (MPC-SP: 1.0 ± 0.73 vs. PLGA-EES: 1.5 ± 0.59, p < 0.05) around the stent strut. MPC-SP showed more increased expression of cluster of differentiation 31, suggesting enhanced re-endothelialization. Conclusion: Compared to PLGA-EES, MPC-SP demonstrated more decreased inflammation of the vascular wall and enhanced re-endothelialization and stent coverage. Hence, MPC-SP has the potential therapeutic benefits for the treatment of coronary artery disease by solving limitations of currently available DESs.


  • Preclinical Evaluation of an Everolimus-Eluting Bioresorbable Vascular Scaffold Via a Long-Term Rabbit Iliac Artery Model

    by Dae Sung Park, Myung Ho Jeong, Yu Jeong Jin, Mi Hyang Na, Doo Sun Sim, Munki Kim, Kyung Hoon Cho, Dae Young Hyun, Seok Oh, Kyung Seob Lim, et al.

    Background: Biodegradable poly (l-lactic acid) (PLLA), a bio safe polymer with a large elastic modulus, is widely used in biodegradable medical devices. However, because of its poor mechanical properties, a PLLA strut must be made twice as thick as a metal strut for adequate blood vessel support. Therefore, the mechanical properties of a drug-eluting metal-based stents (MBS) and a bioresorbable vascular scaffolds (BVS) were evaluated and their safety and efficacy were examined via a long-term rabbit iliac artery model. Methods: The surface morphologies of the MBSs and BVSs were investigated via optical and scanning electron microscopy. An everolimus-eluting (EE) BVS or an EE-MBS was implanted into rabbit iliac arteries at a 1.1:1 stent-to-artery ratio. Twelve months afterward, stented iliac arteries from each group were analyzed via X-ray angiography, optical coherence tomography (OCT), and histopathologic evaluation. Results: Surface morphology analysis of the EE coating on the MBS confirmed that it was uniform and very thin (4.7 μm). Comparison of the mechanical properties of the EE-MBS and EE-BVS showed that the latter outperformed the former in all aspects (radial force (2.75 vs. 0.162 N/mm), foreshortening (0.24% vs. 1.9%), flexibility (0.52 vs. 0.19 N), and recoil (3.2% vs. 6.3%). At all time points, the percent area restenosis was increased in the EE-BVS group compared to the EE-MBS group. The OCT and histopathological analyses indicate no significant changes in strut thickness. Conclusion: BVSs with thinner struts and shorter resorption times should be developed. A comparable long-term safety/efficacy evaluation after complete absorption of BVSs should be conducted.


  • Open Access

    Preclinical Evaluation of a Novel Polymer-free Everolimus-eluting Stent in a Mid-term Porcine Coronary Restenosis Model

    by Kyung Hoon Cho, Myung Ho Jeong, Dae Sung Park, Moonki Kim, JungHa Kim, Jun-Kyu Park, Xiongyi Han, Dae Young Hyun, Min Chul Kim, Doo Sun Sim, et al.

    Cho KH, et al. J Korean Med Sci. 2021 Sep;36(40):e259. https://doi.org/10.3346/jkms.2021.36.e259


  • Open Access

    Effect of dyslipidemia on vascular smooth muscle cell proliferation in a porcine coronary restenosis model

    by Kang Jin Jeong, Philyong Kang, Hwal-Yong Lee, Hee Chang Son, Sung Hyun Park, Won Seok Choi, Bon Sang Koo, Chang-Yeop Jeon, Seug Ho Baek, You Jung An, et al.

    Journal of Biomedical and Translational Research

  • Novel porcine model of acute myocardial infarction using polyethylene terephthalate

    by Yong Sook Kim, Nan Yeol Kim, In-Ho Bae, Jun Kyu Park, Dae Sung Park, Jae Won Shim, Wan Suk Kang, Han Byul Kim, Bong-Seok Song, Bon-Sang Koo, et al.


  • Augmented re-endothelialization and anti-inflammation of coronary drug-eluting stent by abluminal coating with magnesium hydroxide

    by Da-Won Jeong, Wooram Park, Tarek M. Bedair, Eun Young Kang, Ik Hwan Kim, Dae Sung Park, Doo Sun Sim, Young Joon Hong, Won-Gun Koh, Myung Ho Jeong, et al.

    Drug-eluting stents (DESs) have been widely used as a treatment approach for coronary artery diseases. Generally, conventional DESs were fully covered with drugs and biodegradable polymers on both abluminal and luminal layers (i.e., conformal coating). However, uncontrolled drug release from the luminal drug-coating layer of the stent is known to inhibit re-endothelialization. Furthermore, the acidification of the surrounding tissue by the decomposed coating polymer causes inflammation, resulting in restenosis and late thrombosis. To overcome these limitations, here we demonstrated a functional DES coated with poly(lactic-co-glycolic acid) (PLGA), sirolimus (SRL), and magnesium hydroxide (Mg(OH)2, MH) precisely only on the abluminal layer. The acidic neutralization effect of MH was elucidated by measuring the pH change of the fabricated film in PBS solution. In an in vitro cell study, the stent coated with MH exhibited higher compatibility with human coronary artery endothelial cells (ECs) and a lower inflammation score as compared to the control stent. Finally, in an in vivo large porcine model, the abluminal coated DES with SRL and MH showed excellent re-endothelialization and anti-inflammatory and anti-thrombotic effects. In conclusion, it is believed that this approach has great potential for the development of functional DES for the treatment of cardiovascular diseases.