Abstract
The laminated composite magnetic shielding device composed of permalloy and nanocrystalline (PN-MSD) provides a reliable weak magnetic environment for sensors. The PN-MSD needs to reduce the remanence of its shielding materials by demagnetization to improve the shielding performance. First, we design a cage demagnetization coil for PN-MSD to solve the problem that the conventional coils cannot simultaneously balance its flux leakage and magnetization uniformity. Second, since the PN-MSD features a multi-thin-layer attached structure, its demagnetization process cannot be analyzed by the conventional single-material demagnetization model. Therefore, this paper proposes an equivalent demagnetization analysis method to treat the PN-MSD as a whole by deducing the electromagnetic interactions among its material layers. Finally, since the conventional demagnetization field attenuation functions cannot meet the demagnetization requirements of different magnetization regions in PN-MSD, a piecewise attenuation function is proposed to improve its demagnetization effectiveness. Experimental results show that the proposed method reduces the central remanence of PN-MSD by at least 17.74% compared to conventional methods. This paper offers a basis for the demagnetization analysis and optimization of PN-MSD.

This publication has 13 references indexed in Scilit: