Wei Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Liu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Xueping Xu
Beihang University
13 shared publications - Zhenkai Zhao
Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
8 shared publications - Lei Wang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
6 shared publications Zhenkai Zhao
5 shared publicationsWeiwei Wu
3 shared publicationsFengyang Ye
Beihang Univ, Sch Instrumentat & Optoelect Engn, Key Lab Ultraweak Magnet Field Measurement Technol, Minist Educ, Beijing 100191, Peoples R China
1 shared publication
Latest Publications
- 30 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
An integrated and targeted demagnetization method for laminated composite magnetic shielding devices
- 30 October 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 412
An integrated and targeted demagnetization method for laminated composite magnetic shielding devices
- 22 September 2026
- Published by Elsevier in Measurement
- Vol. 292
Calculation model of equivalent magnetic characteristics for composite shields considering permeability differences among laminated materials
- 22 September 2026
- Published by Elsevier in Measurement
- Vol. 292
Calculation model of equivalent magnetic characteristics for composite shields considering permeability differences among laminated materials
- Open Access
- 28 March 2026
- Published by Elsevier in SSRN Electronic Journal
An integrated and targeted demagnetization method for laminated composite magnetic shielding devices
The laminated composite magnetic shielding device composed of permalloy and nanocrystalline (PN-MSD) provides a reliable weak magnetic environment for sensors. The PN-MSD needs to reduce the remanence of its shielding materials by demagnetization to improve the shielding performance. First, we design a cage demagnetization coil for PN-MSD to solve the problem that the conventional coils cannot simultaneously balance its flux leakage and magnetization uniformity. Second, since the PN-MSD features a multi-thin-layer attached structure, its demagnetization process cannot be analyzed by the conventional single-material demagnetization model. Therefore, this paper proposes an equivalent demagnetization analysis method to treat the PN-MSD as a whole by deducing the electromagnetic interactions among its material layers. Finally, since the conventional demagnetization field attenuation functions cannot meet the demagnetization requirements of different magnetization regions in PN-MSD, a piecewise attenuation function is proposed to improve its demagnetization effectiveness. Experimental results show that the proposed method reduces the central remanence of PN-MSD by at least 17.74% compared to conventional methods. This paper offers a basis for the demagnetization analysis and optimization of PN-MSD.
- 28 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAn integrated and targeted demagnetization method for laminated composite magnetic shielding devices
The laminated composite magnetic shielding device composed of permalloy and nanocrystalline (PN-MSD) provides a reliable weak magnetic environment for sensors. The PN-MSD needs to reduce the remanence of its shielding materials by demagnetization to improve the shielding performance. First, we design a cage demagnetization coil for PN-MSD to solve the problem that the conventional coils cannot simultaneously balance its flux leakage and magnetization uniformity. Second, since the PN-MSD features a multi-thin-layer attached structure, its demagnetization process cannot be analyzed by the conventional single-material demagnetization model. Therefore, this paper proposes an equivalent demagnetization analysis method to treat the PN-MSD as a whole by deducing the electromagnetic interactions among its material layers. Finally, since the conventional demagnetization field attenuation functions cannot meet the demagnetization requirements of different magnetization regions in PN-MSD, a piecewise attenuation function is proposed to improve its demagnetization effectiveness. Experimental results show that the proposed method reduces the central remanence of PN-MSD by at least 17.74% compared to conventional methods. This paper offers a basis for the demagnetization analysis and optimization of PN-MSD.
- 7 January 2026
- Published by Elsevier in Measurement
- Vol. 265
Spatial distribution of magnetic noise in P-CA composite magnetic shielding devices under the superposition effect of leakage magnetic flux
- 7 January 2026
- Published by Elsevier in Measurement
- Vol. 265
Spatial distribution of magnetic noise in P-CA composite magnetic shielding devices under the superposition effect of leakage magnetic flux
- Top Cited Papers
- 8 March 2025
- Published by Elsevier in Measurement
- Vol. 251
Theoretical modeling and characterization of equivalent magnetic properties in laminated composite magnetic shielding
- 8 March 2025
- Published by Elsevier in Measurement
- Vol. 251
Top Cited PapersTheoretical modeling and characterization of equivalent magnetic properties in laminated composite magnetic shielding
- Top Cited Papers
- 6 March 2025
- Published by Elsevier in Measurement
- Vol. 250
Modeling and suppression of magnetic noise in nanocrystalline magnetic shielding system considering residual loss magnetic noise and interlayer effects
- 6 March 2025
- Published by Elsevier in Measurement
- Vol. 250
Top Cited PapersModeling and suppression of magnetic noise in nanocrystalline magnetic shielding system considering residual loss magnetic noise and interlayer effects
- 25 February 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 387
Optimized analysis of magnetic noise based on residual magnetization measurements of magnetic shielding devices
- 25 February 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 387
Optimized analysis of magnetic noise based on residual magnetization measurements of magnetic shielding devices