Fiber Orientation Distribution Predictions for an Injection Molded Venturi-Shaped Part Validated Against Experimental Micro-Computed Tomography Characterization
Open Access
- 16 July 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Materials
- Vol. 7
Abstract
This work evaluates and compares the accuracy of different fiber orientation prediction models for a short fiber reinforced injection molded Venturi-shaped part which displays variable thickness. The experimental characterization of the specimen fiber orientation distribution (FOD) was carried out by the micro computed tomography technique (micro-CT). The computational study of fiber orientation predictions was performed using Moldex3D. All the possible combinations of the Folgar-Tucker (FT) and improved Anisotropic Rotary Diffusion (iARD) rotary diffusion models and the Hybrid (Hyb), Orthotropic (ORE), and Invariant Based Optimal Fitting (IBOF) closure approximations were considered. The relevance of the Retardant Principal Rate (RPR) model on predictions results was also evaluated. The values of the fiber-fiber (Ci), matrix-fiber (Cm) interaction coefficients and the alpha-RPR parameter were varied in a significant range in order to find the set of parameters that better fits the experimental fiber orientation data. The parameters' sensitivity effect over the second order orientation tensor components was quantified via the Analysis of Variance (ANOVA) statistical method. The experimental micro-CT results show an increase in the fiber orientation degree at the specimen constriction region due to the narrowed cavity and the Venturi effect. The comparison of the experimental and predicted orientation profiles demonstrates that the predictions of the iARD model, in combination with the IBOF closure approximation, are the most accurate for the case studied. However, simulations fail to estimate the change in orientation caused by variable thickness and section. ANOVA results prove that the orientation tensor component in the flow direction (a11) is more sensitive to changes in alpha-RPR and Ci coefficient, while the perpendicular components (a22, a33) are also significantly affected by Cm. From the predictive error analysis it is seen that the optimal parameters set to capture the orientation state of the specimen is: (i) for the FT model, Ci = 0.005, alpha-RPR = 0.7 and (ii) for the iARD model, Ci = 0.005, Cm = 0.2, and alpha-RPR = 0.7.Keywords
Funding Information
- Ministerio de Ciencia, Tecnología e Innovación
This publication has 24 references indexed in Scilit:
- Comparing non-destructive 3D X-ray computed tomography with destructive optical microscopy for microstructural characterization of fiber reinforced compositesComposites Science and Technology, 2019
- Individual fibre segmentation from 3D X-ray computed tomography for characterising the fibre orientation in unidirectional composite materialsComposites Part A: Applied Science and Manufacturing, 2017
- Invariant-based optimal fitting closure approximation for the numerical prediction of flow-induced fiber orientationJournal of Rheology, 2002
- Numerical analysis of injection molding of glass fiber reinforced thermoplastics. Part 2: Fiber orientationPolymer Engineering & Science, 1997
- Orthotropic closure approximations for flow-induced fiber orientationJournal of Rheology, 1995
- Fiber orientation and mechanical properties of short‐fiber‐reinforced injection‐molded composites: Simulated and experimental resultsPolymer Composites, 1993
- Fiber orientation in simple injection moldings. Part I: Theory and numerical methodsPolymer Composites, 1992
- Closure approximations for three‐dimensional structure tensorsJournal of Rheology, 1990
- The Use of Tensors to Describe and Predict Fiber Orientation in Short Fiber CompositesJournal of Rheology, 1987
- Orientation Behavior of Fibers in Concentrated SuspensionsJournal of Reinforced Plastics and Composites, 1984