Superconducting nanowire single-photon sensing of cerebral blood flow
Open Access
- 19 August 2021
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 8 (03) , 035006-14
Abstract
Diffuse correlation spectroscopy (DCS) is a non-invasive optical method for the measurement of blood flow (BF).1 In DCS, the tissue is illuminated by a long coherence length near-infrared laser, and the speckle pattern formed by moving scatterers, mostly red blood cells, modulates the detected light. The decay of the measured temporal intensity autocorrelation function originated by the speckle fluctuations provides an index of blood flow (),2 with units . To maximize the contrast of the measured speckle, single-mode fibers are used, greatly limiting potential photon throughput. Current DCS devices employing single-photon avalanche photodiodes (SPAD) detectors and laser sources at 700 to 850 nm typically operate at a source-detector (SD) separation of 25 mm and an acquisition rate of 1 Hz.3 Larger SD separations are desirable for improving brain sensitivity and reducing scalp signal contamination, especially in the adult population. Faster acquisition rates are needed to detect fast BF dynamics and effectively remove the large pulsatile systemic component from the cerebral signals. Unfortunately, the low signal-to-noise ratio (SNR) of current devices limits the acquisition rates and prevents the use of SD separations .
Keywords
Funding Information
- National Institutes of Health (U01EB028660)
This publication has 24 references indexed in Scilit:
- Establishing the diffuse correlation spectroscopy signal relationship with blood flowNeurophotonics, 2016
- Ultimate low system dark-count rate for superconducting nanowire single-photon detectorOptics Letters, 2015
- In-vivo multilaboratory investigation of the optical properties of the human headBiomedical Optics Express, 2015
- Diffuse correlation spectroscopy for measurement of cerebral blood flow: future prospectsNeurophotonics, 2014
- Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurementNeuroImage, 2014
- In vivooptical characterization of human tissues from 610 to 1010 nm by time-resolved reflectance spectroscopyPhysics in Medicine & Biology, 2001
- Blood flow in the carotid artery during breath-holding in relation to diving bradycardiaEuropean Journal of Applied Physiology, 1997
- Measurement of the optical properties of the skull in the wavelength range 650-950 nmPhysics in Medicine & Biology, 1993
- Cerebral effects of extended hyperventilation in unanesthetized goats.Stroke, 1987
- Cerebral Hemodynamics, Blood Gases, and Electrolytes during Breath-Holding and the Valsalva ManeuverCirculation, 1966