EXPERIMENTAL STUDY OF FULLY DEVELOPED TURBULENT FLOW IN INTERNALLY FINNED TUBES
Authors:
- 1 January 2025
- journal article
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 32 (2) , 1-26
Abstract
A steady, hydrodynamically and thermally fully developed turbulent water flow in internally finned tubes with constant-heat-flux boundary condition is investigated experimentally. In this experiment, 70°C hot water passes the inner tube while 20°C cold water flows through the annulus passage. In order to eliminate thermal contact resistance, the circular tube having a length of 1400 mm with inner fins is directly milled from a cylinder. Apart from a smooth tube, three internal-finned-tube heat exchangers having 4, 6, and 8 longitudinal trapezoidal fins are tested. For Re = 5000, the tested tubes with 4, 6, and 8 fins can improve thermal performance by approximately 35.4, 44.6, and 67.2%, respectively, but merely increase friction factor by 1.92, 4.8, and 6.73%, respectively, compared to a smooth tube. The increases with respect to to a smooth tube in both Nu and f become smaller at a higher Re for N = 4, 6, and 8. As pressure drop, increases, the Q of the tested finned tubes first grows rapidly, and this growth curve gradually becomes flatter at a higher ΔP. Consequently, the heat-transfer performance will become worse as ΔP > 3.5 kPa for the proposed heat exchangers. Additionally, the performance evaluation criterion (PEC) is proposed to assess the performances of the proposed internally finned tubes. It is shown that the heat exchanger with 8 fins has the best thermo-hydraulic performance. Finally, correlating equations for Nu and f with respect to Re are presented for a range of 3000 ≤ Re ≤ 7250 and N = 0, 4, 6, and 8.Keywords
This publication has 43 references indexed in Scilit:
- Numerical simulation of forced convective heat transfer in inclined elliptic ducts with multiple internal longitudinal finsAlexandria Engineering Journal, 2018
- Performance of tubular aluminum foam heat exchangers in multiple row bundlesJournal of Thermal Analysis and Calorimetry, 2018
- Thermal optimization of internally finned tube with variable fin thicknessApplied Thermal Engineering, 2016
- Performance evaluation of tubular aluminum foam heat exchangers in single row arraysApplied Thermal Engineering, 2015
- Performance evaluation of single tubular aluminium foam heat exchangersApplied Thermal Engineering, 2014
- Effect of lateral fin profiles on turbulent flow and heat transfer performance of internally finned tubesApplied Thermal Engineering, 2009
- Numerical analysis of laminar mixed convection in horizontal internally finned tubesInternational Journal of Heat and Mass Transfer, 1990
- The influence of internal fins on mixed convection inside horizontal tubesInternational Communications in Heat and Mass Transfer, 1985
- Performance evaluation criteria for use of enhanced heat transfer surfaces in heat exchanger designInternational Journal of Heat and Mass Transfer, 1981
- Analysis of fully developed laminar flow in longitudinal internally finned tubesThe Chemical Engineering Journal, 1977