Corneal Biomechanics Following Epi-LASIK
Authors:
- Denise S. RyanDRDenise S. Ryan
- Charles D. CoeCCCharles D. Coe
- Robin S. HowardRHRobin S. Howard
- Jayson D. EdwardsJEJayson D. Edwards
- Kraig S. BowerKBKraig S. Bower
- 1 June 2011
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 27 (6) , 458-464
Abstract
Purpose: To evaluate corneal biomechanical changes following epi-LASIK. Methods: In this prospective study of 51 patients, corneal hysteresis (CH), corneal resistance factor (CRF), and intraocular pressure (IOP) were assessed using the Ocular Response Analyzer (ORA, Reichert Technologies) preoperatively and at 1, 3, 6, and 12 months after epi-LASIK. Repeated measures analysis of variance (ANOVA) was used to compare changes over time (alpha=.05). Intraocular pressure was also measured by Goldmann applanation tonometry. Results: Corneal hysteresis decreased from 10.22±1.65 mmHg preoperatively to 8.17±1.25 mmHg at 1 month, 8.46±1.44 mmHg at 3 months, 8.63±1.31 mmHg at 6 months, and 8.53±1.49 mmHg at 12 months. Corneal resistance factor decreased from 10.01±1.80 mmHg preoperatively to 7.82±1.68, 8.03±1.85, 7.77±1.50, and 7.80±1.66 mmHg at 1, 3, 6, and 12 months, respectively. Repeated measures ANOVA showed a significant change over time for both CH and CRF ( P <.0005). All measures of IOP changed significantly over time ( P <.0005). Conclusions: Epi-LASIK resulted in a significant change in CH and CRF postoperatively. Although some recovery occurred over time, CH, CRF, and IOP did not revert to preoperative levels.Keywords
This publication has 19 references indexed in Scilit:
- Comparison of the Changes in Corneal Biomechanical Properties After Photorefractive Keratectomy and Laser In Situ KeratomileusisCornea, 2009
- Corneal biomechanical measurements before and after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2008
- Repeatability of Intraocular Pressure and Corneal Biomechanical Properties Measurements by the Ocular Response AnalyserKlinische Monatsblätter für Augenheilkunde, 2008
- Corneal hysteresis using the Reichert ocular response analyser: findings pre‐ and post‐LASIK and LASEKActa Ophthalmologica, 2008
- Hysteresis: New mechanospeak for the ophthalmologistJournal of Cataract & Refractive Surgery, 2007
- Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyesJournal of Cataract & Refractive Surgery, 2007
- Diurnal variation of ocular hysteresis in normal subjects: relevance in clinical contextClinical & Experimental Ophthalmology, 2006
- Underestimate of Tonometric Readings after Photorefractive Keratectomy Increases at Higher Intraocular Pressure LevelsInvestigative Ophthalmology & Visual Science, 2005
- Change in Intraocular Pressure Measurements after LASIKThe Effect of the Refractive Correction and the Lamellar FlapOphthalmology, 2005
- Determining in vivo biomechanical properties of the cornea with an ocular response analyzerJournal of Cataract & Refractive Surgery, 2005