JEJayson D. Edwards

Jayson D. Edwards

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jayson D. Edwards has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Denise A. Sediq

    From the Ophthalmology Service (Edwards, Bower, Stutzman, Sediq), Walter Reed Army Medical Center, Department of Ophthalmology (Burka), Georgetown University/Washington Hospital Center, Washington, DC, and Brooks City Base (Rabin), San Antonio, Texas, USA

    2 shared publications
  • Kraig S. Bower

    Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA

    2 shared publications
  • Richard D. Stutzman

    From the Ophthalmology Service (Edwards, Bower, Stutzman, Sediq), Walter Reed Army Medical Center, Department of Ophthalmology (Burka), Georgetown University/Washington Hospital Center, Washington, DC, and Brooks City Base (Rabin), San Antonio, Texas, USA

    2 shared publications
  • Angela Walter

    1 shared publication
  • Cameron R. VanRoekel

    From the Center for Refractive Surgery (Edwards, Bower, Sediq, Stutzman, VanRoekel, Kuzmowych, Eaddy), Walter Reed Army Medical Center, and the Department of Ophthalmology (Burka), Georgetown University/Washington Hospital Center, Washington, DC, USA

    1 shared publication
  • Charles D. Coe

    Ophthalmology Service, Walter Reed Army Medical Center, Washington, District of Columbia 20307-5001, USA

    1 shared publication

Latest Publications

  • Corneal Biomechanics Following Epi-LASIK

    by Denise S. Ryan, Charles D. Coe, Robin S. Howard, Jayson D. Edwards, Kraig S. Bower

    Purpose: To evaluate corneal biomechanical changes following epi-LASIK. Methods: In this prospective study of 51 patients, corneal hysteresis (CH), corneal resistance factor (CRF), and intraocular pressure (IOP) were assessed using the Ocular Response Analyzer (ORA, Reichert Technologies) preoperatively and at 1, 3, 6, and 12 months after epi-LASIK. Repeated measures analysis of variance (ANOVA) was used to compare changes over time (alpha=.05). Intraocular pressure was also measured by Goldmann applanation tonometry. Results: Corneal hysteresis decreased from 10.22±1.65 mmHg preoperatively to 8.17±1.25 mmHg at 1 month, 8.46±1.44 mmHg at 3 months, 8.63±1.31 mmHg at 6 months, and 8.53±1.49 mmHg at 12 months. Corneal resistance factor decreased from 10.01±1.80 mmHg preoperatively to 7.82±1.68, 8.03±1.85, 7.77±1.50, and 7.80±1.66 mmHg at 1, 3, 6, and 12 months, respectively. Repeated measures ANOVA showed a significant change over time for both CH and CRF ( P <.0005). All measures of IOP changed significantly over time ( P <.0005). Conclusions: Epi-LASIK resulted in a significant change in CH and CRF postoperatively. Although some recovery occurred over time, CH, CRF, and IOP did not revert to preoperative levels.


  • Fabry Disease and Chemosis

    by Jayson D Edwards, Kraig S Bower, Dain B Brooks, Angela Walter

    To report the case of a patient with Fabry disease (FD) whose ocular presentation with chronic chemosis we feel is related to FD and to describe the conjunctival fluorescein angiographic findings. A 51-year-old male patient with FD on enzyme replacement therapy presented with 1-month chemosis and mild irritation in the left eye. Ocular examination revealed pronounced noninflammatory chemosis inferotemporally in the left eye with conjunctival tortuosity and microaneurysms bilaterally. There was mild corneal verticillata, spoke-like lens opacities, and retinal vascular tortuosity bilaterally, with no evidence of disc or macular edema. Evaluation revealed no systemic cause for his chemosis, including an orbital computerized tomography scan, which showed clear sinuses and no evidence of an intraorbital mass. Conjunctival fluorescein angiography revealed rapid subconjunctival accumulation of dye in the involved eye but failed to demonstrate leakage from tortuous conjunctival vessels or microaneurysms. Although the pathology of chronic chemosis in patients with FD is as yet unknown, we believe that FD should be considered in the differential diagnosis of patients presenting with chronic chemosis of unknown etiology.


  • Effect of brimonidine tartrate 0.15% on night-vision difficulty and contrast testing after refractive surgery

    by Jayson D. Edwards, Jenna M. Burka, Kraig S. Bower, Richard D. Stutzman, Denise A. Sediq, Jeff C. Rabin

    PURPOSE: To evaluate the efficacy of brimonidine tartrate ophthalmic solution 0.15% in patients with night-vision difficulties after laser refractive surgery. SETTING: Center for Refractive Surgery, Walter Reed Army Medical Center, Washington, District of Columbia, USA. METHODS: Six patients with significant night-vision complaints after refractive surgery were enrolled in this study after other treatable causes of night-vision difficulty such as residual refractive error and dry eye were excluded. Low-contrast visual acuity (LCVA) over a range of contrasts (1.25% to 25%) and small letter contrast sensitivity were tested at photopic (100 cd/m2) and mesopic (1 cd/m2) luminance levels, with and without a standard glare source. Testing was performed before brimonidine tartrate ophthalmic solution 0.15% was administered. Measurements were repeated 1 hour and 1 month after the use of brimonidine tartrate. RESULTS: One hour after using brimonidine tartrate 0.15% solution, patients had significant improvement in LCVA, LCVA with glare, and contrast sensitivity. After 1 month of treatment, all 6 patients reported subjective improvement in night vision and there was a significant difference in performance in mesopic LCVA and mesopic LCVA with glare. The mean pupil size before administration of brimonidine tartrate ophthalmic solution 0.15% was 6.44 mm ± 1.11 (SD). Pupil size 1 hour after instillation had decreased to 4.53 ± 1.27 mm and at 1 month had increased to 6.50 ± 0.94 mm. CONCLUSION: Brimonidine tartrate ophthalmic solution 0.15% improved contrast sensitivity and acuity and decreased night-vision difficulty for up to 1 month in patients with significant complaints after refractive surgery.


  • Effects of lotrafilcon A and omafilcon A bandage contact lenses on visual outcomes after photorefractive keratectomy

    by Jayson D. Edwards, Kraig S. Bower, Denise A. Sediq, Jenna M. Burka, Richard D. Stutzman, Cameron R. VanRoekel, Chrystyna P. Kuzmowych, Jennifer B. Eaddy

    To evaluate postoperative healing between bandage contact lenses with high and low oxygen permeability in patients having photorefractive keratectomy (PRK). Center for Refractive Surgery, Walter Reed Army Medical Center, Washington, DC, USA. This retrospective study compared patients receiving a high-oxygen-transmission bandage contact lens (Focus Night & Day [N&D], Ciba Vision; n = 92) and those receiving a low-oxygen-transmission lens (Proclear, Cooper Vision; n = 114) after PRK. Visual outcomes, safety, and efficacy were assessed postoperatively at 1, 4, and 7 days and 1, 3, 6, and 12 months. Overall pain scores were higher in the Proclear group at 1 day (P = .000) and 4 days (P = .027). The N&D group had an increase in corneal infiltrates at 4 days (P = .025) and 1 week (P = .017). At 1 month, 40.4% of patients in the Proclear group and 18.6% in the N&D group had a 1 or more line decrease in best spectacle-corrected visual acuity (BSCVA) (P = .002). Although there was a trend toward a higher haze rate in the Proclear group, it was not statistically significant (P = .064). There was no statistically significant difference in uncorrected visual acuity, goal of emmetropia, contrast sensitivity, or reepithelialization. The N&D lens produced less pain and better postoperative results in terms of haze and BSCVA at 1 month. However, it led to a higher incidence of corneal infiltrates. There was no difference between the lenses in the end result at 12 months.